CoChat

Nitric oxide is fundamental to neurovascular coupling in humans

Hoiland, Ryan L., Caldwell, Hannah G., Howe, Connor A., Nowak‐Flück, Daniela, Stacey, Benjamin S., Bailey, Damian M., Paton, Julian F. R., Green, Daniel J., Sekhon, Mypinder S., Macleod, David B., Ainslie, Philip N. · 2020 · The Journal of Physiology
Cited by 74

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Key points: Preclinical models have demonstrated that nitric oxide is a key component of neurovascular coupling; this has yet to be translated to humans. We conducted two separate protocols utilizing intravenous infusion of a nitric oxide synthase inhibitor and isovolumic haemodilution to assess the influence of nitric oxide on neurovascular coupling in humans. Isovolumic haemodilution did not alter neurovascular coupling. Intravenous infusion of a nitric oxide synthase inhibitor reduced the neurovascular coupling response by ∼30%, indicating that nitric oxide is integral to neurovascular coupling in humans. Nitric oxide is a vital neurovascular signalling molecule in preclinical models, yet the mechanisms underlying neurovascular coupling (NVC) in humans have yet to be elucidated. To investigate the contribution of nitric oxide to NVC in humans, we utilized a visual stimulus paradigm to elicit an NVC response in the posterior cerebral circulation. Two distinct mechanistic interventions were conducted on young healthy males: (1) NVC was assessed during intravenous infusion of saline (placebo) and the non‐selective competitive nitric oxide synthase inhibitor NG‐monomethyl‐l‐arginine (l‐NMMA, 5 mg kg−1 bolus & subsequent 50 μg kg−1 min−1 maintenance dose; n = 10). The order of infusion was randomized, counterbalanced and single blinded. A subset of participants in this study (n = 4) underwent a separate intervention with phenylephrine infusion to independently consider the influence of blood pressure changes on NVC (0.1–0.6 μg kg−1 min−1 constant infusion). (2) NVC was assessed prior to and following isovolumic haemodilution, whereby 20% of whole blood was removed and replaced with 5% human serum albumin to reduce haemoglobin concentration (n = 8). For both protocols, arterial and internal jugular venous blood samples were collected at rest and coupled with volumetric measures of cerebral blood flow (duplex ultrasound) to quantify resting cerebral metabolic parameters. l‐NMMA elicited a 30% reduction in the peak (P = 0.01), but not average (P = 0.11), NVC response. Neither phenylephrine nor haemodilution influenced NVC. Nitric oxide signalling is integral to NVC in humans, providing a new direction for research into pharmacological treatment of humans with dementia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jp280162

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Hoiland, R. L., Caldwell, H. G., Howe, C. A., Nowak‐Flück, D., Stacey, B. S., Bailey, D. M., Paton, J. F. R., Green, D. J., Sekhon, M. S., Macleod, D. B., & Ainslie, P. N.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2020-08-31
Volume
598
Issue
21
Pages
4927-4939
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W3048397571
Cited by
74
References
11
FWCI
6.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.