The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Voltage clamp analysis of acetylcholine produced end‐plate current fluctuations at frog neuromuscular junction
Open accessAbstract
1. Acetylcholine produced end‐plate current (e.p.c.) noise is shown to be the results of statistical fluctuations in the ionic conductance of voltage clamped end‐plates of Rana pipiens. 2. These e.p.c. fluctuations are characterized by their e.p.c. spectra which conform to a relation predicted from a simple model of end‐plate channel gating behaviour. 3. The rate constant of channel closing α is determined from e.p.c. spectra and is found to depend on membrane potential V according to the relation α = B e AV (B = 0·17 msec−1±0·04 S.E., A = 0·0058 mV−1±0·0009 S.E. at 8° C) and to vary with temperature T with a Q10 = 2·77, at −70 mV. A and B in this expression both vary with T and therefore produce a membrane potential dependent Q10 for α. 4. Nerve‐evoked e.p.c.s and spontaneous miniature e.p.c.s decay exponentially in time with a rate constant which depends exponentially on V. The magnitude and voltage dependence of this decay constant is exactly that found from e.p.c. spectra for the channel closing rate α. 5. The conductance γ of a single open end‐plate channel has been estimated from e.p.c. spectra and is found not to be detectibly dependent on membrane potential, temperature and mean end‐plate current. γ = 0·32±0·0045 ( S.E.) × 10−10 mhos. Some variation in values for γ occurs from muscle to muscle. 6. It is concluded that the relaxation kinetics of open ACh sensitive ionic channels is the rate limiting step in the decay of synaptic current and that this channel closing has a single time constant. The relaxation rate is independent of how it is estimated (ACh produced e.p.c. fluctuations, e.p.c., m.e.p.c.), and is consistent with the hypothesis that individual ionic channels open rapidly to a specific conductance which remains constant for an exponentially distributed duration. 7. The voltage and temperature dependence of the channel closing rate constant agree with the predictions of a simple dipole‐conformation change model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous subthreshold activity at motor nerve endings
Fatt, P., & Katz, B. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004735 · Cited by 1,839
A study of the ‘desensitization’ produced by acetylcholine at the motor end‐plate
Katz, B., & Thesleff, S. (1957) · The Journal of Physiology · doi:10.1113/jphysiol.1957.sp005838 · Cited by 1,461
An analysis of the end‐plate potential recorded with an intra‐cellular electrode
Fatt, P., & Katz, B. (1951) · The Journal of Physiology · doi:10.1113/jphysiol.1951.sp004675 · Cited by 1,400
The statistical nature of the acetylcholine potential and its molecular components
Katz, B., & Miledi, R. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009918 · Cited by 957
Voltage clamp experiments in striated muscle fibres
Adrian, R. H., Chandler, W. K., & Hodgkin, A. L. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009139 · Cited by 520
The effect of voltage on the time course of end‐plate currents
Magleby, K. L., & Stevens, C. F. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009839 · Cited by 442
Self-citationLinear electrical properties of striated muscle fibres observed with intracellular electrodes
Falk, G., & Fatt, P. (1964) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1964.0030 · Cited by 355
Inward and delayed outward membrane currents in isolated neural somata under voltage clamp
Connor, J. A., & Stevens, C. F. (1971) · The Journal of Physiology · doi:10.1113/jphysiol.1971.sp009364 · Cited by 329
Self-citationFrankenhaeuser, B., & Moore, L. E. (1963) · The Journal of Physiology · doi:10.1113/jphysiol.1963.sp007269 · Cited by 254
Membrane Noise produced by Acetylcholine
KATZ, B., & MILEDI, R. (1970) · Nature · doi:10.1038/226962a0 · Cited by 222
Cited by
Single-channel currents recorded from membrane of denervated frog muscle fibres
NEHER, E., & SAKMANN, B. (1976) · Nature · doi:10.1038/260799a0 · Cited by 2,570
The physiology of excitatory amino acids in the vertebrate central nervous system
Mayer, M. L., & Westbrook, G. L. (1987) · Progress in Neurobiology · doi:10.1016/0301-0082(87)90011-6 · Cited by 1,717
Responses of retinal rods to single photons.
Baylor, D. A., Lamb, T. D., & Yau, K. W. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012716 · Cited by 992
Molecular distinction between fetal and adult forms of muscle acetylcholine receptor
Mishina, M., Takai, T., Imoto, K., Noda, M., Takahashi, T., Numa, S., Methfessel, C., & Sakmann, B. (1986) · Nature · doi:10.1038/321406a0 · Cited by 1,001
Local anaesthetics transiently block currents through single acetylcholine‐receptor channels.
Neher, E., & Steinbach, J. H. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012267 · Cited by 844
A patch-clamp study of bovine chromaffin cells and of their sensitivity to acetylcholine
Fenwick, E. M., Marty, A., & Neher, E. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014393 · Cited by 812
Colquhoun, D., & Sakmann, B. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015912 · Cited by 761
Properties of single calcium‐activated potassium channels in cultured rat muscle
Barrett, J. N., Magleby, K. L., & Pallotta, B. S. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014370 · Cited by 709
Ionic basis of GABAA receptor channel function in the nervous system
Kaila, K. (1994) · Progress in Neurobiology · doi:10.1016/0301-0082(94)90049-3 · Cited by 670
Okada, Y. (1997) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1997.273.3.c755 · Cited by 652
Serotonin and cyclic AMP close single K+ channels in Aplysia sensory neurones
Siegelbaum, S. A., Camardo, J. S., & Kandel, E. R. (1982) · Nature · doi:10.1038/299413a0 · Cited by 651
Relaxation and fluctuations of membrane currents that flow through drug-operated channels
Colquhoun, D., & Hawkes, A. G. (1977) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1977.0137 · Cited by 622
Sakmann, B., Patlak, J., & Neher, E. (1980) · Nature · doi:10.1038/286071a0 · Cited by 600
Study, R. E., & Barker, J. L. (1981) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.78.11.7180 · Cited by 561
The Principles of the Stochastic Interpretation of Ion-Channel Mechanisms
Colquhoun, D., & Hawkes, A. G. (1995) · Single-Channel Recording · doi:10.1007/978-1-4419-1229-9_18 · Cited by 555
GABA receptor mechanisms in the central nervous system
Sivilotti, L., & Nistri, A. (1991) · Progress in Neurobiology · doi:10.1016/0301-0082(91)90036-z · Cited by 554
An Efficient Method for Computing Synaptic Conductances Based on a Kinetic Model of Receptor Binding
Destexhe, A., Mainen, Z. F., & Sejnowski, T. J. (1994) · Neural Computation · doi:10.1162/neco.1994.6.1.14 · Cited by 523
Neher, E., Sakmann, B., & Steinbach, J. H. (1978) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00584247 · Cited by 514
The Mauthner Cell Half a Century Later: A Neurobiological Model for Decision-Making?
Korn, H., & Faber, D. S. (2005) · Neuron · doi:10.1016/j.neuron.2005.05.019 · Cited by 469
Two components of electrical dark noise in toad retinal rod outer segments.
Baylor, D. A., Matthews, G., & Yau, K. W. (1980) · The Journal of Physiology · doi:10.1113/jphysiol.1980.sp013529 · Cited by 468
Electrophysiology in the age of light
Scanziani, M., & Häusser, M. (2009) · Nature · doi:10.1038/nature08540 · Cited by 468
The regulation of the calcium conductance of cardiac muscle by adrenaline.
Reuter, H., & Scholz, H. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011657 · Cited by 466
Colquhoun, D., Jonas, P., & Sakmann, B. (1992) · The Journal of Physiology · doi:10.1113/jphysiol.1992.sp019417 · Cited by 433
Heuser, J. E., & Salpeter, S. R. (1979) · The Journal of cell biology · doi:10.1083/jcb.82.1.150 · Cited by 430
Intracellular Ca2+ activates a fast voltage-sensitive K+ current in vertebrate sympathetic neurones
Adams, P. R., Constanti, A., Brown, D. A., & Clark, R. B. (1982) · Nature · doi:10.1038/296746a0 · Cited by 417
Multiple-conductance channels activated by excitatory amino acids in cerebellar neurons
Cull-Candy, S. G., & Usowicz, M. M. (1987) · Nature · doi:10.1038/325525a0 · Cited by 415
Lewis, C. A. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012629 · Cited by 394
Electrically gated ionic channels in lipid bilayers
Ehrenstein, G., & Lecar, H. (1977) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500000123 · Cited by 393
Ionic pores, gates, and gating currents
Armstrong, C. M. (1974) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500001402 · Cited by 356
Colquhoun, D., & Sakmann, B. (1981) · Nature · doi:10.1038/294464a0 · Cited by 353
Activity Coregulates Quantal AMPA and NMDA Currents at Neocortical Synapses
Watt, A. J., van Rossum, M. C. W., MacLeod, K. M., Nelson, S. B., & Turrigiano, G. G. (2000) · Neuron · doi:10.1016/s0896-6273(00)81202-7 · Cited by 350
Drug blockade of open end‐plate channels.
Adams, P. R. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011530 · Cited by 349
Kuffler, S. W., & Yoshikami, D. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011103 · Cited by 332
Multiple conductance states of single acetylcholine receptor channels in embryonic muscle cells
Hamill, O. P., & Sakmann, B. (1981) · Nature · doi:10.1038/294462a0 · Cited by 324
Takahashi, T., Momiyama, A., Hirai, K., Hishinuma, F., & Akagi, H. (1992) · Neuron · doi:10.1016/0896-6273(92)90073-m · Cited by 319
Organization and synaptic physiology of crustacean neuromuscular systems
Atwood, H. L. (1976) · Progress in Neurobiology · doi:10.1016/0301-0082(76)90009-5 · Cited by 317
Horie, M., Irisawa, H., & Noma, A. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016572 · Cited by 298
Ascher, P., Large, W. A., & Rang, H. P. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012958 · Cited by 291
Macroscopic and Microscopic Properties of a Cloned Glutamate Transporter/Chloride Channel
Wadiche, J. I., & Kavanaugh, M. P. (1998) · The Journal of Neuroscience · doi:10.1523/jneurosci.18-19-07650.1998 · Cited by 275
Sine, S. M., Ohno, K., Bouzat, C., Auerbach, A., Milone, M., Pruitt, J. N., & Engel, A. G. (1995) · Neuron · doi:10.1016/0896-6273(95)90080-2 · Cited by 270
Traynelis, S. F., Angus Silver, R., & Cull-Candy, S. G. (1993) · Neuron · doi:10.1016/0896-6273(93)90184-s · Cited by 267
Engel, A. G., Lambert, E. H., Mulder, D. M., Torres, C. F., Sahashi, K., Bertorini, T. E., & Whitaker, J. N. (1982) · Annals of Neurology · doi:10.1002/ana.410110603 · Cited by 263
The actions of tubocurarine at the frog neuromuscular junction.
Colquhoun, D., Dreyer, F., & Sheridan, R. E. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012888 · Cited by 261
Hartzell, H. C., Kuffler, S. W., & Yoshikami, D. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011102 · Cited by 257
Bartol, T. M., Land, B. R., Salpeter, E. E., & Salpeter, M. M. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82344-x · Cited by 217
Numerical reconstruction of the quantal event at nicotinic synapses
Wathey, J. C., Nass, M. M., & Lester, H. A. (1979) · Biophysical Journal · doi:10.1016/s0006-3495(79)85208-x · Cited by 181
Shalinsky, M. H., Magistretti, J., Ma, L., & Alonso, A. A. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.3.1197 · Cited by 65
Metadata
- Authors
- Anderson, C. R., & Stevens, C. F.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1973-12
- Volume
- 235
- Issue
- 3
- Pages
- 655-691
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1977106724
- Cited by
- 986
- References
- 11
- FWCI
- 17.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.