CoChat

Correlative physiological and morphological studies of rapidly adapting mechanoreceptors in cat's glabrous skin.

Open access
Iggo, A, Ogawa, H · 1977 · The Journal of Physiology
Cited by 152

The DOI matches its Crossref record.

Abstract

1. A total of fifty‐four mechanoreceptor afferent units with fast conducting axons in the tibial nerve innervating the glabrous skin of the hind leg were isolated in anaesthetized cats. 2. Twenty‐six rapidly adapting units (RA), eighteen slowly adapting units (SA) and ten Pacinian corpuscle units (PC) were differentiated from each other mainly on the presence of the off response in RA and PC units to a ramp stimulation, the persistence of discharges of the SA units during steady pressure on the receptive field and the classical tuning curve seen in the PC units. A few PC units in the hairy skin were also studied for comparison. 3. Lamellated corpuscles were found histologically in the skin of the receptive field of RA units and identified as Krause's corpuscle of cylindrical type by their superficial location in the cutaneous tissue and their structure revealed by electron microscopy. 4. Physiological characteristics of RA units to various forms of mechanical stimulation were studied and compared with those of the other two kinds of units. SA units had the lowest critical slope among three groups and PC units the highest. 5. The discharge pattern of RA and PC units to a ramp stimulation was found to be time‐locked, whereas with SA unites only the first spike appeared at a fixed latency from the start of stimulation. 6. Some RA units showed a tuning curve which was flat from 10 to 200 Hz. Those with narrowly tuned curves had a best turning frequency at around 20 Hz. They were easily differentiated from the SA and PC units. SA units were tuned best at 5 HZ or less, and PC units at around 200 HZ. 7. The relation between the indentation velocity and amplitude of the ramp and the spike discharges was analysed in eleven RA units. In most cases the relation between identation velocity and maximum instataneous frequency was found to be best fit with a power function although other kinds of functions (linear, logarithmic, and logarithmic hyperbolic tangent) could also fit the relation at the 1% significance level. The instantaneous impuse frequency in RA units in response to various indentation amplitudes showed a step function. 8. The "off" responses to a ramp stimulation in RA units were also analysed in detail.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1977.sp011768

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Iggo, A., & Ogawa, H.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1977-04
Volume
266
Issue
2
Pages
275-296
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2100437836
Cited by
152
References
0
FWCI
3.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.