CoChat

Intensity of sensation related to activity of slowly adapting mechanoreceptive units in the human hand

Open access
Knibestöl, M., Vallbo, Å. B. · 1980 · The Journal of Physiology

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

1. Impulses were recorded from single afferent fibres in the median and ulnar nerves of human subjects. The response of slowly adapting mechanosensitive units with receptive fields in the glabrous skin of the hand were studied when rectangular indentations of varying amplitudes and invariant time duration were delivered. Simultaneously the subject was asked to estimate the magnitude of his sensation associated with the stimuli. 2. Stimulus—response plots of the afferent units were constructed and compared with the psychophysical magnitude estimation plots. 3. The stimulus—response data of the afferent units fell along monotonous curves which were largely decelerating when stimuli above the static threshold were taken into account. When responses below the static threshold were taken into account many plots were S‐shaped. 4. The psychophysical plots were monotonous and either decelerating, linear or accelerating. 5. Power functions were fitted to the two sets of data. The group average differed considerably with regard to the exponent of the fitted functions which was 0·7 for the neural and 1·0 for the psychophysical function. 6. There was considerable variation between shapes of curves derived from individual test points. The range of exponents for the neural function was 0·26‐1·92 and for the psychophysical function 0·36‐2·09. The variation in psychophysical functions was partly accounted for by relatively stable inter‐subject differences, whereas no such inter‐subject difference was evident for the neural functions, which seemed to vary randomly. 7. There was no indication of a correlation between the shapes of the neural functions and the shapes of the psychophysical functions when data from individual subjects or individual test points were compared. Moreover, when two groups of data were considered, one with accelerating and one with decelerating psychophysical functions, the associated neural functions did not differ between the two groups. 8. It was concluded that the hypothesis of a close agreement between the stimulus—response functions of slowly adapting mechanoreceptors in the human hand and the psychophysical magnitude estimation functions is not tenable. This was evident when average group data were compared as well as when data from individual subjects and individual target points were compared. The findings suggest that the shapes of the psychophysical magnitude estimation functions are highly dependent on central mechanisms and are not a direct function of the properties of the afferent units as has been claimed in previous investigations.

Overview

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1980.sp013160

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 17 references

Cited by

Items 101–183 of 183

Metadata

Authors
Knibestöl, M., & Vallbo, Å. B.
Affiliations
Umeå University (SE)
Venue
The Journal of Physiology
Publisher
Wiley
Published
1980-03
Volume
300
Issue
1
Pages
251-267
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2048295387
Cited by
181
References
17
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 3 · 2022: 2 · 2021: 2 · 2019: 2 · 2018: 2 · 2017: 3 · 2016: 2 · 2015: 2 · 2014: 2 · 2013: 2 · 2012: 4
FWCI
2.93
Type
journal article
Language
en
Open access
Locations
  • The Journal of Physiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Life Sciences › Neuroscience › Sensory Systems › Ion Channels and Receptors
Keywords
slowly adapting mechanoreceptors, human hand, stimulus-response function, afferent nerve fibers, median nerve, ulnar nerve, glabrous skin, power function fitting, interindividual variability
MeSH terms
Adult, Hand, Humans, Mechanoreceptors, Neurons, Afferent, Physical Stimulation, Psychophysiology, Skin, Touch

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.