Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 311

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Calcium entry and transmitter release at voltage‐clamped nerve terminals of squid.

Open access
Augustine, G J, Charlton, M P, Smith, S J·1985·The Journal of Physiology

Abstract

Presynaptic and post‐synaptic cells of the squid giant synapse were voltage‐clamped simultaneously to study the relationship between presynaptic Ca current and transmitter‐induced post‐synaptic current (p.s.c.). Local Ca application was used to restrict Ca current and transmitter release to a limited region of the presynaptic terminal and thus minimize errors due to spatial heterogeneity of presynaptic membrane potential. Presynaptic terminals were depolarized by brief (3‐6 ms) voltage‐clamp pulses of varying amplitude to collect graded series of presynaptic Ca current and p.s.c. records. During presynaptic depolarization at 14 degrees C, Ca current activation preceded initial onset of p.s.c. (on‐p.s.c.) by an interval of approximately 1 ms. The main component of on‐p.s.c. followed Ca current activation by about 2 ms. The delay between a brief Ca tail current and peak response of the p.s.c. produced after pulse termination (off‐p.s.c.) was also approximately 2 ms. Curves relating both Ca current and p.s.c. magnitudes to presynaptic potential were bell shaped with peaks near ‐10 mV, but the p.s.c. curve showed stronger voltage dependence on both sides of the peak. With very small and very large presynaptic command pulses, Ca current could be observed without measureable p.s.c. Synaptic transfer curves, plotting p.s.c. as a function of presynaptic Ca current, resembled third‐power functions. On the average, p.s.c.s fit a curve representing the 2.9 power of Ca current (range 2.4‐3.5 in eighteen experiments). Transfer curves consisted of two limbs: one from presynaptic pulses below ‐10 mV and the other from more positive pulses. These two limbs were similar and generally resembled power functions of identical exponent. It is thus likely that the third‐power function accurately reflects synaptic current transfer, rather than interference from some other voltage‐dependent process. Power functions fitting small‐pulse and large‐pulse limbs of some transfer curves had different scale coefficients, even though exponent values were the same. Consideration of synaptic transmission kinetics suggests that the voltage dependence of Ca channel opening rates can probably explain the difference in transfer curve limbs. Our experiments provide no evidence for an intrinsic voltage dependence of the transmitter release process.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1985.sp015819

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 311

Metadata

Authors
Augustine, G. J., Charlton, M. P., & Smith, S. J.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1985-10
Volume
367
Issue
1
Pages
163-181
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2075174600
Cited by
311
References
22
FWCI
3.63
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.