Rectification of currents activated by nicotinic acetylcholine receptors in rat sympathetic ganglion neurones.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
1. The inward rectification of the whole‐cell current evoked by acetylcholine (ACh) and other nicotinic agonists in rat sympathetic ganglion neurones has been studied using patch‐clamp recording techniques. The selective nicotinic agonist 1,1‐dimethyl‐4‐phenylpiperazinium iodide (DMPP) (20 microM) induced an average peak current of ‐367 pA at ‐50 mV but no detectable outward current at +50 mV. Similar observations were made with ACh and carbachol. 2. The current‐voltage relation of the whole‐cell response induced by DMPP was linear in the negative voltage range; however, there was no detectable outward current in the voltage range 0 to about +70 mV. Above +70 mV an outward current became clearly detectable. Rapid depolarizing jumps in the holding potential failed to reveal any rapidly decaying outward current. 3. The rectification was not alleviated by changing the main permeant cation, by removal of divalent cations from the intracellular or extracellular solutions or by altering the pH buffer in the extracellular solution from HEPES to Tris. 4. Intracellular magnesium ions can block the channel. This effect increases with depolarization, but dissociation outwards (i.e. permeation by Mg2+) appears to relieve the block at more extreme positive potentials. This effect alone, or in combination with the voltage dependence of the burst length, is unlikely to be able to account for the whole‐cell rectification in intact cells, much less that seen in cells perfused with Mg2(+)‐free intracellular medium. 5. When the reversal potential was shifted to approximately ‐50 mV (by the use of impermeant cations) nicotinic agonists produced small outward currents in the membrane potential range ‐20 to +10 mV while shifting it to about +40 mV produced small inward currents in the potential range 0 to +20 mV. The rectification therefore appears to be independent of the direction of current flow and is maximum at a potential positive to 0 mV. 6. At positive potentials the receptors desensitized much less than at negative potentials in the continued presence of agonist. Thus, exposure of the cells to a steady application of 30 microM‐ACh produced no detectable response if the cell was at a positive potential, but when the cell was stepped to a negative potential in the continued presence of ACh (at a time when much of the ACh current would be expected to have desensitized), ACh induced a large inward current. The onset of the ACh current had a time constant of 10 ms. It then decayed with a time constant of 790 ms as desensitization developed.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A patch-clamp study of bovine chromaffin cells and of their sensitivity to acetylcholine
Fenwick, E. M., Marty, A., & Neher, E. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014393 · Cited by 812
Cited by
The Diversity of Neuronal Nicotinic Acetylcholine Receptors
Sargent, P. B. (1993) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.16.030193.002155 · Cited by 1,052
Bowie, D., & Mayer, M. L. (1995) · Neuron · doi:10.1016/0896-6273(95)90049-7 · Cited by 579
Desensitization of neuronal nicotinic receptors
Quick, M. W., & Lester, R. A. J. (2002) · Journal of Neurobiology · doi:10.1002/neu.10109 · Cited by 456
Brain nicotinic receptors: structure and regulation, role in learning and reinforcement
Changeux, J.-P., Bertrand, D., Corringer, P.-J., Dehaene, S., Edelstein, S., Léna, C., Le Novère, N., Marubio, L., Picciotto, M., & Zoli, M. (1998) · Brain Research Reviews · doi:10.1016/s0165-0173(97)00040-4 · Cited by 322
Docherty, R. J., Yeats, J. C., Bevan, S., & Boddeke, H. W. G. M. (1996) · Pflügers Archiv European Journal of Physiology · doi:10.1007/bf02332166 · Cited by 302
Metadata
- Authors
- Mathie, A., Colquhoun, D., & Cull‐Candy, S. G.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1990-08
- Volume
- 427
- Issue
- 1
- Pages
- 625-655
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2026431577
- Cited by
- 115
- References
- 1
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.