Co‐ordination of contractile activity in guinea‐pig mesenteric lymphatics.
Open accessThe DOI matches its Crossref record.
Abstract
1. Intraluminally perfused lymphatic vessels from the mesentery of the guinea‐pig were examined in vitro to investigate their contractile activity and the co‐ordination of this activity between adjacent lymphangions. 2. Lymphangions constricted at fairly regular intervals and exhibited ‘refractory’ periods of up to 3 s during which constrictions did not occur. 3. The contractile activity of adjacent lymphangions was highly co‐ordinated. 4. The smooth muscle was found to be continuous between the adjacent lymphangions for the majority of valve regions examined morphologically (52 of 63 preparations). 5. Mechanical and electrical coupling between adjacent lymphangions was indicated, as some lymphangions underwent transient dilatations just prior to constriction, whereas direct electrophysiological measurements showed that the smooth muscle of most adjacent lymphangions was electrically coupled across the valve (15 out of 20 pairs of lymphangions). 6. It is concluded that perfused lymphangions of guinea‐pig mesenteric lymphatic vessels rhythmically constrict, with the contractile activity of adjacent lymphangions highly co‐ordinated. The findings also indicate that transmission of both mechanical and electrical signals between the adjacent lymphangions contribute to the co‐ordination of their contractile activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lymphatic pumping: mechanics, mechanisms and malfunction
Scallan, J. P., Zawieja, S. D., Castorena‐Gonzalez, J. A., & Davis, M. J. (2016) · The Journal of Physiology · doi:10.1113/jp272088 · Cited by 424
“Robust and nearly synchronous contractions of a single layer of LMCs are evident.”
BackgroundInfluentialContractile Physiology of Lymphatics
Zawieja, D. C. (2009) · Lymphatic Research and Biology · doi:10.1089/lrb.2009.0007 · Cited by 368
Moore, J. E., & Bertram, C. D. (2018) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-122316-045259 · Cited by 340
Gasheva, O. Y., Zawieja, D. C., & Gashev, A. A. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.115212 · Cited by 181
“Contrary to this idea, numerous reports have demonstrated the propagation of contractile waves along lymphatic vessels (McHale & Roddie, 1976; McHale & Meharg, 1992; Zawieja et al. 1993; Crowe et al. 1997).”
ResultWhat Is the Role of Vascular Endothelial Growth Factor-Related Molecules in Tumor Angiogenesis?
Nicosia, R. F. (1998) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)65539-3 · Cited by 163
“This in turn may affect the extent of lymphatic permeation and the rate of metastasis, because lymph is propelled to lymph nodes by periodic contractions of lymphatic vessels.(55) In addition, cancer cells that produce VEGF-C or VEGF-D and metastasize to lymph nodes may have a growth advantage because of their capacit…”
BackgroundIntrinsic increase in lymphangion muscle contractility in response to elevated afterload
Davis, M. J., Scallan, J. P., Wolpers, J. H., Muthuchamy, M., Gashev, A. A., & Zawieja, D. C. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01097.2011 · Cited by 133
Zawieja, S. D., Castorena-Gonzalez, J. A., Scallan, J. P., & Davis, M. J. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00499.2017 · Cited by 89
Local Regulation of Microvascular Perfusion
Davis, M. J., Hill, M. A., & Kuo, L. (2008) · Microcirculation · doi:10.1016/b978-0-12-374530-9.00006-1 · Cited by 78
Nepiyushchikh, Z. V., Chakraborty, S., Wang, W., Davis, M. J., Zawieja, D. C., & Muthuchamy, M. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2011.218446 · Cited by 37
Metadata
- Authors
- Crowe, M. J., von der Weid, P. Y., Brock, J. A., & Van Helden, D. F.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1997-04
- Volume
- 500
- Issue
- 1
- Pages
- 235-244
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1994203773
- Cited by
- 68
- References
- 0
- FWCI
- 0.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.