CoChat

Recovery of the human photopic electroretinogram after bleaching exposures: estimation of pigment regeneration kinetics

Open access
Mahroo, O. A. R., Lamb, T. D. · 2004 · The Journal of Physiology
Cited by 92

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

We used a fibre electrode in the lower conjunctival sac of the human eye to record the a‐wave of the photopic electroretinogram elicited in response to dim red flashes, delivered in the presence of a rod‐saturating blue background, before and after exposure of the eye to bright white illumination that bleached a significant fraction of cone photopigment. Responses were recorded from two normal subjects whose pupils were maximally dilated. A range of intensities of bleaching light were used, from 500 to 3000 photopic cd m−2, and exposures were made sufficiently long in duration to achieve a steady‐state bleach. In addition, responses were also recorded following shorter durations of exposures to the highest intensity (3000 cd m−2); these durations ranged from 5 to 60 s. The amplitude of the a‐wave response to dim flashes was reduced following the exposures, with brighter or longer exposures causing greater reduction. The amplitude then recovered within about 4 min to the prebleach level. The amplitudes measured at ca 15 ms after the flash were used to derive the effective intensity of the flashes, thereby quantifying the fraction of photopigment available at the time of delivery of each flash. Recovery from all exposures in both subjects followed a common time course, which could be described well by a model of pigment kinetics based on rate‐limited regeneration, where the initial rate of recovery following a total bleach was ca 50% of the total pigment per minute, and the residual pigment level for half the maximal rate was ca 20% of the total pigment. The same parameters, together with a fixed photosensitivity, could account for the steady‐state pigment levels seen at each bleaching intensity, and also for the fraction of pigment bleached following exposures of different duration at the highest intensity. The dim‐flash ERG thus provides a novel method for assessing pigment regeneration in vivo. Our finding that pigment regeneration follows rate‐limited kinetics may explain previous reports of pigment regeneration deviating from first order kinetics. We present a model of regeneration in which the rate limit arises from a limitation in the delivery of 11‐cis‐retinoid to the photoreceptor outer segments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2003.051250

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Mahroo, O. A. R., & Lamb, T. D.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2004-01
Volume
554
Issue
2
Pages
417-437
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1603053514
Cited by
92
References
4
FWCI
1.93
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.