Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Skeletal muscle pump versus respiratory muscle pump: modulation of venous return from the locomotor limb in humans

Miller, Jordan D., Pegelow, David F., Jacques, Anthony J., Dempsey, Jerome A.·2005·The Journal of Physiology

Abstract

The vast majority of quantitative data examining the effects of breathing on venous return have been derived from anaesthetized or reduced animal preparations, making an extrapolation to an upright exercising human problematic due to the lack of a hydrostatic column and an absence of muscular contraction. Thus, this study is the first to quantitatively examine the effects of different breathing mechanics on venous return from the locomotor limbs both at rest and during calf contraction exercise in the semirecumbent human. When subjects inspired using predominantly their ribcage/accessory inspiratory muscles at rest (change in gastric pressure(Δ PGA) = <2 cmH 2 O, change in oesophageal pressure(Δ PES) =∼−6 cmH 2 O; inspiratory time/total breath time (TI/TTOT) = 0.5), a slight facilitation of femoral venous return was observed during inspiration (65% of all flow occurred during inspiration), with a slight reduction in femoral venous return during the ensuing expiratory phase of the breath. However, when subjects inspired using a predominantly diaphragmatic breath at rest(Δ PGA= > 5 cmH 2 O, Δ PES=∼−6 cmH 2 O;TI/TTOT= 0.5), femoral venous return was markedly impeded (net retrograde flow of 11%) and significantly lower than that observed during ribcage breathing conditions (P< 0.01). During the ensuing expiratory phase of a diaphragmatic breath, there was a large resurgence of femoral venous blood flow. The pattern of modulation during ribcage and diaphragmatic breathing persisted during both mild (peak calf force = 7 kg) and moderate (peak calf force = 11 kg) levels of calf contraction. Despite the significant within‐breath modulation of femoral venous return by breathing, net blood flow in the steady state was not altered by the breathing pattern followed by the subjects. Though popliteal blood flow appeared to be modulated by respiration at rest, this pattern was absent during mild calf contraction where popliteal outflow was phasic with the concentric phase of calf contraction. We conclude that respiratory muscle pressure production is the predominant factor modulating venous return from the locomotor limb both at rest and during calf contraction even when the veins of the lower limb are distended due to the presence of a physiologic hydrostatic column.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2004.076422

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Miller, J. D., Pegelow, D. F., Jacques, A. J., & Dempsey, J. A.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2005-03
Volume
563
Issue
3
Pages
925-943
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1579183288
Cited by
171
References
1
FWCI
13.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.