Ionic mechanisms of autorhythmic firing in rat cerebellar Golgi cells
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Although Golgi cells (GoCs), the main type of inhibitory interneuron in the cerebellar granular layer (GL), are thought to play a central role in cerebellar network function, their excitable properties have remained unexplored. GoCs fire rhythmically in vivo and in slices, but it was unclear whether this activity originated from pacemaker ionic mechanisms. We explored this issue in acute cerebellar slices from 3‐week‐old rats by combining loose cell‐attached (LCA) and whole‐cell (WC) recordings. GoCs displayed spontaneous firing at 1–10 Hz (room temperature) and 2–20 Hz (35–37°C), which persisted in the presence of blockers of fast synaptic receptors and mGluR and GABA B receptors, thus behaving, in our conditions, as pacemaker neurons. ZD 7288 (20 μ m), a potent hyperpolarization‐activated current (Ih) blocker, slowed down pacemaker frequency. The role of subthreshold Na+ currents (INa,sub) could not be tested directly, but we observed a robust TTX‐sensitive, non‐inactivating Na+ current in the subthreshold voltage range. When studying repolarizing currents, we found that retigabine (5 μ m), an activator of KCNQ K+ channels generating neuronal M‐type K+ (IM) currents, reduced GoC excitability in the threshold region. The KCNQ channel antagonist XE991 (5 μ m) did not modify firing, suggesting that GoC IM has low XE991 sensitivity. Spike repolarization was followed by an after‐hyperpolarization (AHP) supported by apamin‐sensitive Ca 2+‐dependent K+ currents (Iapa). Block of Iapa decreased pacemaker precision without altering average frequency. We propose that feed‐forward depolarization is sustained by Ih and INa,sub, and that delayed repolarizing feedback involves an IM‐like current whose properties remain to be characterized. The multiple ionic mechanisms shown here to contribute to GoC pacemaking should provide the substrate for fine regulation of firing frequency and precision, thus influencing the cyclic inhibition exerted by GoCs onto the cerebellar GL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Llinás, R. R. (1988) · Science · doi:10.1126/science.3059497 · Cited by 2,285 · cited 2×
“Answering this question is critical in view of the role played by neuronal excitability in determining network behaviours (Llinás, 1988).”
BackgroundSynchronization of cortical activity and its putative role in information processing and learning
Singer, W. (1993) · Annual Review of Physiology · doi:10.1146/annurev.ph.55.030193.002025 · Cited by 1,685
[6] Correction for liquid junction potentials in patch clamp experiments
Neher, E. (1992) · Methods in Enzymology · doi:10.1016/0076-6879(92)07008-c · Cited by 1,132 · cited 1×
“The liquid junction potential (ELJ) between the bath and pipette solution was measured according to Neher (1992), and was 10 mV. ELJ has been subtracted from membrane potential (V m) measurements throughout the text.”
MethodSantoro, B., Chen, S., Lüthi, A., Pavlidis, P., Shumyatsky, G. P., Tibbs, G. R., & Siegelbaum, S. A. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-14-05264.2000 · Cited by 600 · cited 2×
“mRNAs coding for the Ih channel subtype hcn2 (mouse; Santoro et al. 2000) and hcn2 protein (rat; Notomi & Shigemoto, 2004) were detected in the GL with a distribution compatible with their presence in GoCs.”
BackgroundMaccaferri, G., & McBain, C. J. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021754 · Cited by 503 · cited 2×
“The decrease of firing frequency induced in GoCs by ZD 7288 suggests that Ih contributes to the subthreshold pacemaker depolarization, as found in other low-frequency pacemaker neurons (Maccaferri & McBain, 1996; Bennett et al. 2000; Neuhoff et al. 2002; Funahashi et al. 2003; Chan et al. 2004).”
BackgroundGu, N., Vervaeke, K., Hu, H., & Storm, J. F. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.086835 · Cited by 363 · cited 2×
“However, effects of XE991 on cells maintained in resting, hyperpolarized conditions have also been reported (Yu & Yaari, 2004; Gu et al. 2005).”
BackgroundCooper, E. C., Harrington, E., Jan, Y. N., & Jan, L. Y. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-24-09529.2001 · Cited by 305
Hallworth, N. E., Wilson, C. J., & Bevan, M. D. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-20-07525.2003 · Cited by 210
Cited by
The action potential in mammalian central neurons
Bean, B. P. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2148 · Cited by 1,785
Davis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Vervaeke, K., Lőrincz, A., Gleeson, P., Farinella, M., Nusser, Z., & Silver, R. A. (2010) · Neuron · doi:10.1016/j.neuron.2010.06.028 · Cited by 231
Pedarzani, P., & Stocker, M. (2008) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-008-8216-x · Cited by 173
Metadata
- Authors
- Elisabetta Cesana, L. F., Mapelli, J., & D'Angelo, E.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2006-07-21
- Volume
- 574
- Issue
- 3
- Pages
- 711-729
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1550335362
- Cited by
- 132
- References
- 8
- FWCI
- 3.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.