CoChat

Ionic mechanisms of autorhythmic firing in rat cerebellar Golgi cells

Open access
Elisabetta Cesana, Lia Forti, Mapelli, Jonathan, D'Angelo, Egidio · 2006 · The Journal of Physiology
Cited by 132

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Although Golgi cells (GoCs), the main type of inhibitory interneuron in the cerebellar granular layer (GL), are thought to play a central role in cerebellar network function, their excitable properties have remained unexplored. GoCs fire rhythmically in vivo and in slices, but it was unclear whether this activity originated from pacemaker ionic mechanisms. We explored this issue in acute cerebellar slices from 3‐week‐old rats by combining loose cell‐attached (LCA) and whole‐cell (WC) recordings. GoCs displayed spontaneous firing at 1–10 Hz (room temperature) and 2–20 Hz (35–37°C), which persisted in the presence of blockers of fast synaptic receptors and mGluR and GABA B receptors, thus behaving, in our conditions, as pacemaker neurons. ZD 7288 (20 μ m), a potent hyperpolarization‐activated current (Ih) blocker, slowed down pacemaker frequency. The role of subthreshold Na+ currents (INa,sub) could not be tested directly, but we observed a robust TTX‐sensitive, non‐inactivating Na+ current in the subthreshold voltage range. When studying repolarizing currents, we found that retigabine (5 μ m), an activator of KCNQ K+ channels generating neuronal M‐type K+ (IM) currents, reduced GoC excitability in the threshold region. The KCNQ channel antagonist XE991 (5 μ m) did not modify firing, suggesting that GoC IM has low XE991 sensitivity. Spike repolarization was followed by an after‐hyperpolarization (AHP) supported by apamin‐sensitive Ca 2+‐dependent K+ currents (Iapa). Block of Iapa decreased pacemaker precision without altering average frequency. We propose that feed‐forward depolarization is sustained by Ih and INa,sub, and that delayed repolarizing feedback involves an IM‐like current whose properties remain to be characterized. The multiple ionic mechanisms shown here to contribute to GoC pacemaking should provide the substrate for fine regulation of firing frequency and precision, thus influencing the cyclic inhibition exerted by GoCs onto the cerebellar GL.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2006.110858

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 132

Metadata

Authors
Elisabetta Cesana, L. F., Mapelli, J., & D'Angelo, E.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2006-07-21
Volume
574
Issue
3
Pages
711-729
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1550335362
Cited by
132
References
8
FWCI
3.56
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.