The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Human phase response curve to a 1 h pulse of bright white light
Open accessAbstract
Key points: The human circadian pacemaker generates near‐24‐h rhythms that set the timing of many physiological, metabolic and behavioural body rhythms, and is synchronized to environmental time primarily by the 24 h light–dark cycle. The magnitude and direction of the resetting response of the pacemaker to light depends on the time of day of exposure, and the change in responses over the day is summarized in a phase response curve (PRC). A previous PRC showed that a 6.7 h bright white light exposure maximally shifted the circadian pacemaker by over 3 h. We show that a PRC to a 1 h bright white light pulse maximally shifted the circadian pacemaker by ∼2 h, despite representing only ∼15% of the exposure duration. This study demonstrates that the circadian pacemaker is sensitive to short‐duration light pulses with a non‐linear relationship between light duration and the amount of resetting. Abstract The phase resetting response of the human circadian pacemaker to light depends on the timing of exposure and is described by a phase response curve (PRC). The current study aimed to construct a PRC for a 1 h exposure to bright white light (∼8000 lux) and to compare this PRC to a <3 lux dim background light PRC. These data were also compared to a previously completed 6.7 h bright white light PRC and a <15 lux dim background light PRC constructed under similar conditions. Participants were randomized for exposure to 1 h of either bright white light (n= 18) or <3 lux dim background light (n= 18) scheduled at 1 of 18 circadian phases. Participants completed constant routine (CR) procedures in dim light (<3 lux) before and after the light exposure to assess circadian phase. Phase shifts were calculated as the difference in timing of dim light melatonin onset (DLMO) during pre‐ and post‐stimulus CRs. Exposure to 1 h of bright white light induced a Type 1 PRC with a fitted peak‐to‐trough amplitude of 2.20 h. No discernible PRC was observed in the <3 lux dim background light PRC. The fitted peak‐to‐trough amplitude of the 1 h bright light PRC was ∼40% of that for the 6.7 h PRC despite representing only 15% of the light exposure duration, consistent with previous studies showing a non‐linear duration–response function for the effects of light on circadian resetting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Geometry of Biological Time
Winfree, A. T. (1980) · doi:10.1007/978-3-662-22492-2 · Cited by 3,613
Stability, precision, and near-24-hour period of the human circadian pacemaker
Czeisler, C. A., Duffy, J. F., Shanahan, T. L., Brown, E. N., Mitchell, J. F., Rimmer, D. W., Ronda, J. M., Silva, E. J., Allan, J. S., Emens, J. S., et al. (1999) · Science · doi:10.1126/science.284.5423.2177 · Cited by 1,705 · cited 5×
“1997) or when exposed to a light–dark cycle with stimulus strength that is too weak to support entrainment, the circadian pacemaker usually exhibits a near-24-h period (Middleton et al. 1996; Czeisler et al. 1999; Wright et al. 2001).”
BackgroundMethodInfluentialZeitzer, J. M., Dijk, D., Kronauer, R. E., Brown, E. N., & Czeisler, C. A. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.00695.x · Cited by 1,175
Self-citationA Phase Response Curve to Single Bright Light Pulses in Human Subjects
Khalsa, S. B. S., Jewett, M. E., Cajochen, C., & Czeisler, C. A. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2003.040477 · Cited by 1,040 · cited 10×
“7 h exposure (Khalsa et al. 2003) and the heretofore unpublished PRC for the ∼15 lux background light used in that protocol.”
BackgroundMethodInfluentialSelf-citationBright Light Induction of Strong (Type 0) Resetting of the Human Circadian Pacemaker
Czeisler, C. A., Kronauer, R. E., Allan, J. S., Duffy, J. F., Jewett, M. E., Brown, E. N., & Ronda, J. M. (1989) · Science · doi:10.1126/science.2734611 · Cited by 946
Self-citationA human phase-response curve to light
Minors, D. S., Waterhouse, J. M., & Wirz-Justice, A. (1991) · Neuroscience Letters · doi:10.1016/0304-3940(91)90051-t · Cited by 640
Sex difference in the near-24-hour intrinsic period of the human circadian timing system
Duffy, J. F., Cain, S. W., Chang, A.-M., Phillips, A. J. K., Münch, M. Y., Gronfier, C., Wyatt, J. K., Dijk, D.-J., Wright, K. P., & Czeisler, C. A. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1010666108 · Cited by 607
Self-citationGooley, J. J., Chamberlain, K., Smith, K. A., Khalsa, S. B. S., Rajaratnam, S. M. W., Van Reen, E., Zeitzer, J. M., Czeisler, C. A., & Lockley, S. W. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2098 · Cited by 565
Self-citationThe effects of prior light history on the suppression of melatonin by light in humans
Hébert, M., Martin, S. K., Lee, C., & Eastman, C. I. (2002) · Journal of Pineal Research · doi:10.1034/j.1600-079x.2002.01885.x · Cited by 413 · cited 1×
“…et al. 1988; Jasser et al. 2006) and phase shift the human circadian pacemaker (Zeitzer et al. 2000; Burgess et al. 2003; Gooley et al. 2011), particularly (but not necessarily) if preceded by dimmer light or darkness (Hebert et al. 2002; Smith et al. 2004; Jasser et al. 2006; Chang et al. 2011).”
BackgroundGetting Through to Circadian Oscillators: Why Use Constant Routines?
Duffy, J. F., & Dijk, D.-J. (2002) · Journal of Biological Rhythms · doi:10.1177/074873002129002294 · Cited by 368
Cited by
Entrainment of the Human Circadian Clock to the Natural Light-Dark Cycle
Wright, K. P., McHill, A. W., Birks, B. R., Griffin, B. R., Rusterholz, T., & Chinoy, E. D. (2013) · Current Biology · doi:10.1016/j.cub.2013.06.039 · Cited by 783
Phillips, A. J. K., Clerx, W. M., O’Brien, C. S., Sano, A., Barger, L. K., Picard, R. W., Lockley, S. W., Klerman, E. B., & Czeisler, C. A. (2017) · Scientific Reports · doi:10.1038/s41598-017-03171-4 · Cited by 647
Self-citationBrown, T. M., Brainard, G. C., Cajochen, C., Czeisler, C. A., Hanifin, J. P., Lockley, S. W., Lucas, R. J., Münch, M., O’Hagan, J. B., Peirson, S. N., et al. (2022) · PLOS Biology · doi:10.1371/journal.pbio.3001571 · Cited by 659
Self-citationCho, Y., Ryu, S.-H., Lee, B. R., Kim, K. H., Lee, E., & Choi, J. (2015) · Chronobiology International · doi:10.3109/07420528.2015.1073158 · Cited by 485
Systematic review of light exposure impact on human circadian rhythm
Tähkämö, L., Partonen, T., & Pesonen, A.-K. (2019) · Chronobiology International · doi:10.1080/07420528.2018.1527773 · Cited by 535
Metadata
- Authors
- St Hilaire, M. A., Gooley, J. J., Khalsa, S. B. S., Kronauer, R. E., Czeisler, C. A., & Lockley, S. W.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2012-06-14
- Volume
- 590
- Issue
- 13
- Pages
- 3035-3045
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2165804665
- Cited by
- 277
- References
- 33
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human phase response curve to a 1 h pulse of bright white light. https://app.cochat.ai/papers/10.1113/jphysiol.2012.227892
- The paper
- St Hilaire, M. A., Gooley, J. J., Khalsa, S. B. S., Kronauer, R. E., Czeisler, C. A., & Lockley, S. W. (2012). Human phase response curve to a 1 h pulse of bright white light. The Journal of Physiology. https://doi.org/10.1113/jphysiol.2012.227892
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.