CoChat

CrossTalk opposing view: Loop gain is not a consequence of obstructive sleep apnoea

Open access
Orr, J. E., Edwards, B. A., Malhotra, A. · 2014 · The Journal of Physiology
Cited by 25

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Obstructive sleep apnoea (OSA) is a common disease affecting at least 13% of adult men and 6% of adult women in the United States (Peppard et al. 2013) and is characterized by repetitive collapse (apnoea) or partial collapse (hypopnoea) of the pharyngeal airway during sleep (Sullivan & Issa, 1985; Guilleminault et al. 1986; Young et al. 1993; Hamilton et al. 2004). Recent studies suggest that OSA is a multifactorial condition, and not just an anatomical problem (Wellman et al. 2011; Eckert et al. 2013). Alongside anatomical vulnerability, at least three additional physiological traits interact to contribute to the development of OSA including (1) ineffective upper airway dilator muscles, (2) a low threshold for arousal from sleep, and (3) a hypersensitive ventilatory control system (i.e. high loop gain) (Dempsey et al. 2010). In individual patients, the manifestation of OSA may be the result of one or more combinations of abnormalities, and thus multiple underlying causes may need to be addressed for sleep apnoea to be resolved. Interestingly, recent evidence has questioned whether some of these traits such as a high loop gain are truly pathogenic (i.e. an intrinsic cause of OSA) or merely reflect a consequence of the disorder. Loop gain characterizes the sensitivity of the negative feedback system controlling ventilation and is defined as the size of a 'corrective' ventilatory response divided by the size of the ventilatory disturbance that elicits the correction (see Fig. 1); a large response to a small disturbance represents a system with a high loop gain. In favour of an elevated loop gain being an acquired condition (i.e. a consequence of disease) are two investigations whose findings demonstrate that treatment of OSA leads to major reductions in loop gain. Salloum et al. examined the effect of one month of nasal continuous positive airway pressure (CPAP) therapy on the components of the ventilatory control system – plant and controller gain – in a group of recently diagnosed and untreated severe OSA patients (Salloum et al. 2010). They reported that one month of treatment led to reductions in the ventilatory sensitivity to CO2 (i.e. controller gain), and thus loop gain (as plant gain remained unchanged), back to levels similar to healthy controls. In another study, Loewen et al. measured the dynamic ventilatory response to CO2 in a group of severe OSA patients before and after one month of CPAP therapy (Loewen et al. 2009). Similar to the study by Salloum et al., Loewen et al. observed that ventilatory sensitivity to CO2 was markedly diminished following CPAP therapy; taken together, such findings seem to suggest that a high loop gain is a consequence of OSA. Simplified block diagram of the respiratory control system. A ventilatory disturbance (change in expiratory minute ventilation, (disturbance), shown in blue) produces a change in alveolar (). The amount of change in alveolar depends on the properties of the plant (which represents the lungs, blood and body tissues where CO2 is stored). After a circulation delay, this changes the at the chemoreceptors (, shown in red). This change in chemoreceptor produces a change in ventilation ( (response)) based on the sensitivity of the controller that acts to correct the initial disturbance. Loop gain, which takes into account the plant, circulation delay and the controller gain, is defined as the magnitude of the ventilatory response divided by the magnitude of the ventilatory disturbance. A large loop gain ratio indicates an unstable system prone to oscillations, and a low loop gain indicates a stable system. Note that oxygen reduces controller gain whereas acetazolamide reduces plant gain. However, we would argue that the findings of these two investigations do not provide conclusive evidence that an elevated loop gain is solely a consequence of OSA. An important implication of the aforementioned studies is that one month of effective treatment was sufficient to reverse the consequences of disease and allowed an individual's 'intrinsic' physiology to be assessed. However, studies that have manipulated loop gain in CPAP-treated OSA patients have consistently shown that lowering the 'intrinsic' loop gain is associated with an improvement in OSA severity, highlighting the importance of loop gain as a cause of OSA. For instance, administration of oxygen, which is known to lower loop gain via reductions in controller gain, led to marked improvement in OSA among those patients with elevated loop gain at baseline (Wellman et al. 2008; Chowdhuri et al. 2010). No such improvement was observed in patients with low loop gain, highlighting that the intrinsic elevation in loop gain (at baseline) was pathophysiologically important in some OSA patients. In addition to oxygen therapy, the administration of acetazolamide has also been shown to lower loop gain and OSA severity (Edwards et al. 2012, 2013). Furthermore, the use of cardiac resynchronization therapy as a treat

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2014.271841

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Orr, J. E., Edwards, B. A., & Malhotra, A.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2014-07-15
Volume
592
Issue
14
Pages
2903-2905
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2127462278
Cited by
25
References
7
FWCI
2.14
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.