Variability of a Three-Dimensional Finite Element Model Constructed Using Magnetic Resonance Images of a Knee for Joint Contact Stress Analysis
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Magnetic resonance (MR) imaging has been widely used to evaluate the thickness and volume of articular cartilage both in vivo and in vitro. While morphological information on the cartilage can be obtained using MR images, image processing for extracting geometric boundaries of the cartilage may introduce variations in the thickness of the cartilage. To evaluate the variability of using MR images to construct finite element (FE) knee cartilage models, five investigators independently digitized the same set of MR images of a human knee. The topology of cartilage thickness was determined using a minimal distance algorithm. Less than 8 percent variation in cartilage thickness was observed from the digitized data. The effect of changes in cartilage thickness on contact stress analysis was then investigated using five FE models of the knee. One FE model (average FE model) was constructed using the mean values of the digitized contours of the cartilage, and the other four were constructed by varying the thickness of the average FE model by ±5 percent and ±10 percent, respectively. The results demonstrated that under axial tibial compressive loading (up to 1400 N), variations of cartilage thickness caused by digitization of MR images may result in a difference of approximately 10 percent in peak contact stresses (surface pressure, von Mises stress, and hydrostatic pressure) in the cartilage. A reduction of cartilage thickness caused increases of contact stresses, while an increase of cartilage thickness reduced contact stresses. Furthermore, the effect of variation of material properties of the cartilage on contact stress analysis was investigated. The peak contact stress increased almost linearly with the Young’s modulus of the cartilage. The peak von Mises stress was dramatically reduced when the Poisson’s ratio was increased from 0.05 to 0.49 under an axial compressive load of 1400 N, while peak hydrostatic pressure was dramatically increased. Peak surface pressure was also increased with the Poisson’s ratio, but with a lower magnitude compared to von Mises stress and hydrostatic pressure. In conclusion, the imaging process may cause 10 percent variations in peak contact stress, and the predicted stress distribution is sensitive to the accuracy of the material properties of the cartilage model, especially to the variation of Poisson’s ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
Fukubayashi, T., & Kurosawa, H. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990887 · Cited by 813
Interspecies comparisons of in situ intrinsic mechanical properties of distal femoral cartilage
Athanasiou, K. A., Rosenwasser, M. P., Buckwalter, J. A., Malinin, T. I., & Mow, V. C. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090304 · Cited by 750
Load-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci.
Kurosawa, H., Fukubayashi, T., & Nakajima, H. (1980) · PubMed · Cited by 528
Articular contact in a three-dimensional model of the knee
Blankevoort, L., Kuiper, J. H., Huiskes, R., & Grootenboer, H. J. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90019-j · Cited by 520
Butler, D. L., Kay, M. D., & Stouffer, D. C. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90019-9 · Cited by 513
Biphasic indentation of articular cartilage—I. Theoretical analysis
Mak, A. F., Lai, W. M., & Mow, V. C. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90036-4 · Cited by 478
Load-Bearing Mode of the Knee Joint: Physical Behavior of the Knee Joint with or Without Menisci
KUROSAWA, H., FUKUBAYASHI, T., & NAKAJIMA, H. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198006000-00039 · Cited by 469
Mink, J. H., & Deutsch, A. L. (1989) · Radiology · doi:10.1148/radiology.170.3.2916038 · Cited by 467
Peterfy, C. G., van Dijke, C. F., Janzen, D. L., Glüer, C.-C., Namba, R., Majumdar, S., Lang, P. K., & Genant, H. K. (1994) · Radiology · doi:10.1148/radiology.192.2.8029420 · Cited by 404
A three-dimensional mathematical model of the knee-joint
Wismans, J., Veldpaus, F., Janssen, J., Huson, A., & Struben, P. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90354-1 · Cited by 351
A Validated Three-Dimensional Computational Model of a Human Knee Joint
Li, G., Gil, J., Kanamori, A., & Woo, S. L.-Y. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2800871 · Cited by 264
Self-citationTaylor, S. J. G., Walker, P. S., Perry, J. S., Cannon, S. R., & Woledge, R. (1998) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(98)90009-2 · Cited by 246
Validation of a three-dimensional model of the knee
Blankevoort, L., & Huiskes, R. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00149-2 · Cited by 226
Can muscle co-contraction protect knee ligaments after injury or repair?
O'Connor, J. (1993) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.75b1.8421032 · Cited by 205
A musculoskeletal model of the knee for evaluating ligament forces during isometric contractions
Shelburne, K. B., & Pandy, M. G. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00119-4 · Cited by 200
Bendjaballah, M., Shirazi-Adl, A., & Zukor, D. (1995) · The Knee · doi:10.1016/0968-0160(95)00018-k · Cited by 184
An analytical model of the knee
Crowninshield, R., Pope, M. H., & Johnson, R. J. (1976) · Journal of Biomechanics · doi:10.1016/0021-9290(76)90117-2 · Cited by 182
A transversely isotropic biphasic finite element model of the meniscus
Spilker, R. L., Donzelli, P. S., & Mow, V. C. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90038-3 · Cited by 179
Donzelli, P. S., Spilker, R. L., Ateshian, G. A., & Mow, V. C. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00106-2 · Cited by 160
Ateshian, G. A., Rosenwasser, M. P., & Mow, V. C. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90102-7 · Cited by 159
Solloway, S., Hutchinson, C. E., Waterton, J. C., & Taylor, C. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370620 · Cited by 148
Model studies of the stiffness characteristics of the human knee joint
Andriacchi, T. P., Mikosz, R. P., Hampton, S. J., & Galante, J. O. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90043-x · Cited by 122
Piplani, M. A., Disler, D. G., McCauley, T. R., Holmes, T., & Cousins, J. P. (1996) · Radiology · doi:10.1148/radiology.198.3.8628883 · Cited by 111
A Two-Dimensional Dynamic Anatomical Model of the Human Knee Joint
Abdel-Rahman, E. M., & Hefzy, M. S. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895498 · Cited by 93
Analytical stereophotogrammetric determination of three-dimensional knee-joint geometry
Huiskes, R., Kremers, J., de Lange, A., Woltring, H. J., Selvik, G., & van Rens, T. J. G. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90011-9 · Cited by 92
Ligament Forces at the Knee during Isometric Quadriceps Contractions
Zavatsky, A. B., & O'Connor, J. J. (1993) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/pime_proc_1993_207_263_02 · Cited by 50
Haut, T. L., Hull, M. L., & Howell, S. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00049-9 · Cited by 35
van Leersum, M., Schweitzer, M. E., Gannon, F. H., Vinitski, S., Finkel, G. C., & Mitchell, D. G. (1995) · Skeletal Radiology · doi:10.1007/bf00941240 · Cited by 17
Finite Element Model of the Human Knee Joint to Study Tibio-Femoral Contact Mechanics
Donahue, T. H., Hull, M. L., Rashid, M. M., & Jacobs, C. R. (2000) · ASME International Mechanical Engineering Congress and Exposition (IMECE) · doi:10.1115/imece2000-2562 · Cited by 4
Cited by
Peña, E., Calvo, B., Martínez, M. A., & Doblaré, M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.030 · Cited by 506
Muscle and Joint Function in Human Locomotion
Pandy, M. G., & Andriacchi, T. P. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105259 · Cited by 325
Peña, E., Calvo, B., Martínez, M. A., Palanca, D., & Doblaré, M. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.01.009 · Cited by 285
Ameye, L. G., & Chee, W. S. (2006) · Arthritis Research & Therapy · doi:10.1186/ar2016 · Cited by 225
Chan, D. D., Cai, L., Butz, K. D., Trippel, S. B., Nauman, E. A., & Neu, C. P. (2016) · Scientific Reports · doi:10.1038/srep19220 · Cited by 158
Metadata
- Authors
- Li, G., Lopez, O., & Rubash, H.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2001-03-13
- Volume
- 123
- Issue
- 4
- Pages
- 341-346
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W1983624537
- Cited by
- 210
- References
- 30
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.