The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Computational Analysis of Coupled Blood-Wall Arterial LDL Transport
Abstract
The transport of macromolecules, such as low density lipoproteins (LDLs), across the artery wall and their accumulation in the wall is a key step in atherogenesis. Our objective was to model fluid flow within both the lumen and wall of a constricted, axisymmetric tube simulating a stenosed artery, and to then use this flow pattern to study LDL mass transport from the blood to the artery wall. Coupled analysis of lumenal blood flow and transmural fluid flow was achieved through the solution of Brinkman’s model, which is an extension of the Navier-Stokes equations for porous media. This coupled approach offers advantages over traditional analyses of this problem, which have used possibly unrealistic boundary conditions at the blood-wall interface; instead, we prescribe a more natural pressure boundary condition at the adventitial vasa vasorum, and allow variations in wall permeability due to the occurrence of plaque. Numerical complications due to the convection dominated mass transport process (low LDL diffusivity) are handled by the streamline upwind/Petrov-Galerkin (SUPG) finite element method. This new fluid-plus-porous-wall method was implemented for conditions typical of LDL transport in a stenosed artery with a 75 percent area reduction (Peclet number=2×108). The results show an elevated LDL concentration at the downstream side of the stenosis. For the higher Darcian wall permeability thought to occur in regions containing atheromatous lesions, this leads to an increased transendothelial LDL flux downstream of the stenosis. Increased transmural filtration in such regions, when coupled with a concentration-dependent endothelial permeability to LDL, could be an important contributor to LDL infiltration into the arterial wall. Experimental work is needed to confirm these results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Microfluidic perfusion models that are used to model early stage atherosclerosis and later thrombosis have a significant potential in drug development [291–294].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [294]
Citations
Cites
Brooks, A. N., & Hughes, T. J. R. (1982) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(82)90071-8 · Cited by 5,332
The Low-Density Lipoprotein Pathway and its Relation to Atherosclerosis
Goldstein, L. J., & Brown, S. M. (1977) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.46.070177.004341 · Cited by 1,906
Zarins, C. K., Giddens, D. P., Bharadvaj, B. K., Sottiurai, V. S., Mabon, R. F., & Glagov, S. (1983) · Circulation Research · doi:10.1161/01.res.53.4.502 · Cited by 1,485
Caro, C. G., Fitz-Gerald, J. M., & Schroter, R. C. (1971) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1971.0019 · Cited by 1,357
Physicochemical hydrodynamics: an introduction
(1995) · Choice Reviews Online · doi:10.5860/choice.32-3319 · Cited by 878
Flow patterns and spatial distribution of atherosclerotic lesions in human coronary arteries.
Asakura, T., & Karino, T. (1990) · Circulation Research · doi:10.1161/01.res.66.4.1045 · Cited by 856
Gown, A. M., Tsukada, T., & Ross, R. (1986) · PubMed · Cited by 676
Neale, G., & Nader, W. (1974) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450520407 · Cited by 556
The Role of Fluid Mechanics in the Localization and Detection of Atherosclerosis
Giddens, D. P., Zarins, C. K., & Glagov, S. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895545 · Cited by 490
FLOW THROUGH INTERSTITIUM AND OTHER FIBROUS MATRICES
Levick, J. R. (1987) · Quarterly Journal of Experimental Physiology · doi:10.1113/expphysiol.1987.sp003085 · Cited by 480
Research works printed but not linked: 5
- Stangeby, D. K., and Ethier, C. R., 2000, “Computational analysis of convection dominated transport in two media: arterial mass transport,” Proceedings, Conference on Mathematical Modeling and Scientific Computing.
- Ethier, C. R., Steinman, D. A., and Ojha, M., 1999, “Comparisons between computational hemodynamics, photochromic dye flow visualization and magnetic resonance velocimetry,” Haemodynamics of Arterial Organs. X. Y. Xu and M. W. Collins, eds., WIT Press, Southampton, pp. 131–183.
- Wada, S., and Karino, T., 1999, “Relationship between wall shear stress and surface concentration of lipoproteins calculated for a multiple bend of the human right coronary artery,” V. K. Goel et al., eds., Proceedings, 1999 Bioengineering Conference, BED Vol. 42, ASME Press, New York, pp. 735–736.
- Steinman, D. A., 1993, “Numerical Analysis of Flow in a 2-D Distensible Model of an End-to-Side Anastomosis,” Ph.D. thesis, University of Toronto.
- Fatouraec, N., Deng, X., De Champlain, A., and Guidoin, R., 1999, “Numerical simulation of lipid transport through arterial stenoses,” V. K. Goel et al., eds., Proceedings, 1999 Bioengineering Conference, BED Vol. 42, ASME Press, New York, pp. 733–734.
Cited by
Applied Mathematical Modelling
Breusers, H. N. C. (1976) · Journal of Hydraulic Research · doi:10.1080/00221687609499673 · Cited by 288
Cardiovascular disease models: A game changing paradigm in drug discovery and screening
Savoji, H., Mohammadi, M. H., Rafatian, N., Toroghi, M. K., Wang, E. Y., Zhao, Y., Korolj, A., Ahadian, S., & Radisic, M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.036 · Cited by 223
Modeling of low-density lipoprotein (LDL) transport in the artery—effects of hypertension
Yang, N., & Kambiz Vafai, B. (2005) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.09.019 · Cited by 198
“Stangeby and Ethier [6] have cited that the estimated endothelial LDL diffusive permeability at 160 mmHg is four times greater interface based upon the different values of the lumen outlet pressure. endothelium interface for the steady flow model based upon the different than the value measured at normal vascular pres…”
BackgroundMethodInfluentialA coupling model for macromolecule transport in a stenosed arterial wall
Ai, L., & Kambiz Vafai, B. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.10.041 · Cited by 197
“The third factor is that the permeability of the wall may be pressure dependent [8].”
BackgroundInfluentialProsi, M., Zunino, P., Perktold, K., & Quarteroni, A. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.04.024 · Cited by 187
Olgaç, U., Kurtcuoglu, V., & Dimos Poulikakos, A. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01082.2007 · Cited by 150
“Wada et al. (40) used a wall-free model to study the concentration polarization phenomenon, and Kaazempur-Mofrad and Ethier (13) calculated the mass transport in a realistic human right coronary artery.”
MethodResultComputational Modeling of Mass Transfer and Links to Atherosclerosis
Ethier, C. R. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1468890 · Cited by 132
Self-citationOlgaç, U., Dimos Poulikakos, A., Saur, S. C., Alkadhi, H., & Kurtcuoglu, V. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01182.2008 · Cited by 114
“This three-pore model proved to be able to better represent the dependence of blood plasma and LDL transport through the endothelium on the local blood flow characteristics than the single pathway approaches of Stangeby and Ethier (50) and Sun et al. (53).”
InfluentialHossain, S. S., Hossainy, S., Bazilevs, Y., Calo, V. M., & Hughes, T. J. R. (2011) · Computational Mechanics · doi:10.1007/s00466-011-0633-2 · Cited by 109
“Ai and Vafai [4] reported the following (see Table 3) parameters for macromolecular transport in artery walls based on the work of Karner et al. [32], Stangeby and Ethier [52], and references therein.”
BackgroundSun, N., Wood, N. B., Hughes, A. D., Thom, S., & Xu, X. Y. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9144-2 · Cited by 105
Numerical simulation of drug eluting coronary stents: Mechanics, fluid dynamics and drug release
Zunino, P., D'angelo, C., Petrini, L., Vergara, C., Capelli, C., & Migliavacca, F. (2008) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2008.07.019 · Cited by 101
“Assuming again the elastic strain small and the rate of deformation as total strain rate measure, it is possible to describe the inelastic behavior of the stent using the additive strain rate decomposition: ε̇ = ε̇el+ ε̇ pl where ε̇el and ε̇ pl are the elastic and plastic components of the total…”
MethodMoradicheghamahi, J., Sadeghiseraji, J., & Jahangiri, M. (2018) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2018.10.046 · Cited by 87
Valencia, Á., & Villanueva, M. (2006) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2006.05.006 · Cited by 86
“Setting Φ=0 on arterial walls is appropriate in this case, because convective effects dominate LDL transport in the arterial walls, [11].”
BackgroundInfluentialSun, N., Wood, N. B., Hughes, A. D., Thom, S., & Xu, X. Y. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01281.2006 · Cited by 85
“The single-layered models assume that the arterial wall behaves as one layer of porous medium with homogeneous transport properties, and this approach has been employed to model oxygen and LDL transport (22, 29, 30, 32).”
MethodMultiphysics Simulation of Blood Flow and LDL Transport in a Porohyperelastic Arterial Wall Model
Koshiba, N., Ando, J., Chen, X., & Hisada, T. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2720914 · Cited by 83
den Buijs, J. O., Musters, M., Verrips, T. C., Post, J. A., Braam, B. G., & van Riel, N. A. W. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00332.2004 · Cited by 86
In Silico Vascular Modeling for Personalized Nanoparticle Delivery
Hossain, S. S., Zhang, Y. J., Liang, X., Hussain, F., Mauro Ferrari, B., Hughes, T. J. R., & Decuzzi, P. (2012) · Nanomedicine · doi:10.2217/nnm.12.124 · Cited by 81
An Integrated Finite-Element Approach to Mechanics, Transport and Biosynthesis in Tissue Engineering
Sengers, B. G., Oomens, C. W. J., & Baaijens, F. F. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1645526 · Cited by 81
Theoretical models for coronary vascular biomechanics: Progress & challenges
Waters, S. L., Alastruey, J., Beard, D. A., Bovendeerd, P. H. M., Davies, P. F., Jayaraman, G., Jensen, O. E., Lee, J., Parker, K. H., Popel, A. S., et al. (2010) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2010.10.001 · Cited by 83
Tada, S., & Tarbell, J. M. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00647.2003 · Cited by 74
Low-density lipoprotein (LDL) transport in an artery – A simplified analytical solution
Yang, N., & Kambiz Vafai, B. (2007) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2007.05.023 · Cited by 73
“A better approach is to model the arterial wall as a homogeneous porous monolayer [5,6].”
BackgroundChung, S., & Kambiz Vafai, B. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.10.002 · Cited by 72
“These models, are widely used to study mass transfer within arteries (Rappitsch and Perktold, 1996; Wada and Karino, 2000; Moore and Ethier, 1997; Stangeby and Ethier, 2002a,b).”
MethodShahzadi, I., Duraihem, F. Z., Ijaz, S., Raju, C. S. K., & Saleem, S. (2023) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2023.106679 · Cited by 65
Computer simulation of three-dimensional plaque formation and progression in the carotid artery
Filipović, N., Teng, Z., Radovic, M. D., Saveljic, I. B., Fotiadis, D. I., & Parodi, O. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1031-4 · Cited by 64
“Stangeby and Ethier [18] analyzed the wall as single-layer porous medium and solved the coupled luminal blood flow and transmural fluid flow using Brinkman’s equations.”
MethodFreestanding hierarchical vascular structures engineered from ice
Wang, R., Ozsvar, J., Aghaei‐Ghareh‐Bolagh, B., Hiob, M. A., Mithieux, S. M., & Weiss, A. S. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.11.011 · Cited by 62
Large eddy simulation of LDL surface concentration in a subject specific human aorta
Lantz, J., & Karlsson, M. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.11.039 · Cited by 55
“The transport of LDL was modeled as a passive non-reacting scalar, with inlet concentration set to 1.2 mg/ml following Stangeby and Ethier (2002), and a zero concentration gradient was assumed at all outlets.”
BackgroundMethodInfluentialIasiello, M., Kambiz Vafai, B., Andreozzi, A., Bianco, N. D., & Tavakkoli, F. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1196-0 · Cited by 54
Wall shear stress on LDL accumulation in human RCAs
Soulis, J. V., Fytanidis, D. K., Papaioannou, V. C., & Giannoglou, G. D. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.05.011 · Cited by 52
“For the shear dependent K coefficient, the following equation is sed [1],”
Factors that affect mass transport from drug eluting stents into the artery wall
O’Connell, B. M., McGloughlin, T. M., & Walsh, M. T. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-15 · Cited by 52
“In 2002, Stangeby and Ethier [6] analysed the transport of macromolecules, such as low density Figure 2 Drug eluting stent strut cross-sections.”
Iasiello, M., Kambiz Vafai, B., Andreozzi, A., & Bianco, N. D. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.12.015 · Cited by 52
“, 2013), in which an homogeneous layer represents the arterial wall (Stangeby and Ethier, 2002), and multi-layer model, in which the heterogeneity of the wall layers is taken into account (Yang and Vafai, 2006; Ai and Vafai, 2006).”
BackgroundSun, N., Torii, R., Wood, N. B., Hughes, A. D., Thom, S., & Xu, X. Y. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.3005161 · Cited by 51
Chung, S., & Kambiz Vafai, B. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.09.030 · Cited by 49
Kenjereš, S., & de Loor, A. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0941 · Cited by 49
“[8]).”
Coupled Computational Analysis of Arterial LDL Transport -- Effects of Hypertension
Stangeby, D. K., & Ethier, C. R. (2002) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840290010733 · Cited by 46
“In previous work, we reduced some of the limitations associated with existing lumenal mass transport models through the development of the fluid-plus-porous-wall method (FPPWM), which couples transmural fluid flow in the artery wall to the motion of flowing blood in the arterial lumen [23,24].”
BackgroundMethodInfluentialSelf-citationValencia, Á., & Baeza, F. (2008) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2008.10.006 · Cited by 44
Ley, O., & Kim, T. (2007) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-6-8 · Cited by 42
“Such geometries are adopted based on previous studies dealing with mass transport [25-27] and stress concentrations in atherosclerotic plaques [28-30]; all of which provide useful physical insight and enable the reproduction of qualitative features while reducing the computational work/costs of threedimensional (3D) m…”
The Effects of Time Varying Curvature on Species Transport in Coronary Arteries
Kolandavel, M. K., Fruend, E.-T., Ringgaard, S., & Walker, P. G. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9188-3 · Cited by 41
A multiphysics approach for modeling early atherosclerosis
Thon, M. P., Hemmler, A., Glinzer, A., Mayr, M., Wildgruber, M., Zernecke, A., & Gee, M. W. (2017) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-017-0982-7 · Cited by 40
“40 × 107] being in the physiological regime of LDL transport (Stangeby and Ethier 2002).”
BackgroundInfluentialA mass transfer model of temporal drug deposition in artery walls
Abraham, J., Gorman, J. M., Sparrow, E. M., Stark, J. R., & Kohler, R. E. (2012) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2012.11.053 · Cited by 39
Influence of Pulsatile Flow on LDL Transport in the Arterial Wall
Sun, N., Wood, N. B., Hughes, A. D., Thom, S., & Xu, X. Y. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9347-1 · Cited by 38
The Tolerance of the Maxilla to Blunt Impact
Cormier, J. M., Manoogian, S. J., Bisplinghoff, J. A., Rowson, S., Santago, A. C., McNally, C., Duma, S. M., & Bolte, J. H. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004248 · Cited by 35
Hossain, S. S., Zhang, Y. J., Fu, X., Brunner, G., Singh, J. V., Hughes, T. J. R., Shah, D. J., & Decuzzi, P. (2015) · Journal of The Royal Society Interface · doi:10.1098/rsif.2015.0001 · Cited by 34
“This assumption is deemed reasonable for sufficiently small particles travelling in large vessels [41,42].”
BackgroundRoustaei, M., Nikmaneshi, M. R., & Firoozabadi, B. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.11.029 · Cited by 32
Effect of heat and mass transfer on non-Newtonian flow – Links to atherosclerosis
Sarifuddin, S., Chakravarty, S., & Mandal, P. K. (2009) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2009.04.040 · Cited by 30
“This feature is well agreed with the observation of Stangeby and Either [42].”
ResultSharifzadeh, B., Kalbasi, R., Jahangiri, M., Toghraie, D. S., & Karimipour, A. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105442 · Cited by 29
The role of endothelial calcium and nitric oxide in the localisation of atherosclerosis
Plank, M. J., Wall, D. J. N., & David, T. (2006) · Mathematical Biosciences · doi:10.1016/j.mbs.2006.08.017 · Cited by 28
“For example, Wada and Karino [13] modelled low-density lipoprotein (LDL) concentration in the human right coronary artery; Stangeby and Ethier [14] modelled LDL concentration in a stenosed two-dimensional arterial geometry; Shen et al.”
Assémat, P., Armitage, J. A., Siu, K. K. W., Contreras, K. G., Dart, A. M., Chin-Dusting, J. P. F., & Hourigan, K. (2014) · Applied Mathematical Modelling · doi:10.1016/j.apm.2014.01.004 · Cited by 28
UNSTEADY ANALYSIS OF VISCOELASTIC BLOOD FLOW THROUGH ARTERIAL STENOSIS
Ikbal, M. A., Chakravarty, S., Sarifuddin, S., & Mandal, P. K. (2011) · Chemical Engineering Communications · doi:10.1080/00986445.2011.569802 · Cited by 27
“The present approach differs considerably from that of others who have calculated or analyzed similar problems, in the sense that Leuprecht and Perktold (2000) used finite-element method, while Bodnar et al. (2010) used a finite-volume method rather than finite-difference method.”
ResultInfluentialViscoelastic blood flow through arterial stenosis—Effect of variable viscosity
Ikbal, M. A. (2012) · International Journal of Non-Linear Mechanics · doi:10.1016/j.ijnonlinmec.2012.05.006 · Cited by 27
Sarifuddin, S., Chakravarty, S., Mandal, P. K., & Layek, G. C. (2008) · Journal of Medical Engineering & Technology · doi:10.1080/03091900601164820 · Cited by 27
“The inlet velocity conditions were assumed to have a parabolic velocity profile corresponding to HagenPoiseuille flow through a long circular tube even in the unsteady state, conforming with the studies carried out by Rappitsch and Perktold [30] and Stangeby and Ethier [31] as:”
ResultProsi, M., Perktold, K., & Schima, H. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.10.017 · Cited by 26
Analyses of radiation impedances of finite cylindrical ducts
Shao, W., & Mechefske, C. K. (2005) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2004.11.017 · Cited by 24
Influence of Oscillating Flow on LDL Transport and Wall Shear Stress in the Normal Aortic Arch
Soulis, J. V., Giannoglou, G. D., Dimitrakopoulou, M., Papaioannou, V. C., Logothetides, S., & Mikhailidis, D. P. (2009) · The Open Cardiovascular Medicine Journal · doi:10.2174/1874192400903010128 · Cited by 23
“Keywords: Unsteady Low-density lipoprotein Transport, Wall Shear Stress, Atherosclerosis, Aortic Arch.”
Low-density lipoprotein concentration in the normal left coronary artery tree
Soulis, J. V., Giannoglou, G. D., Papaioannou, V. C., Parcharidis, G. E., & Louridas, G. E. (2008) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-7-26 · Cited by 23
“The transportation of Low-Density Lipoproteins (LDL) across the artery wall is considered to be a step of paramount importance in atherosclerosis [6,7].”
BackgroundEffect of branchings on blood flow in the system of human coronary arteries
Wiwatanapataphee, B., Wu, Y., Siriapisith, T., & Nuntadilok, B. (2011) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2012.9.199 · Cited by 23
Analysis of the effect of stent emplacement on LDL transport within an artery
Wang, S., & Kambiz Vafai, B. (2013) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.05.041 · Cited by 22
“[10] D.K. Stangeby, C.R. Ethier, Computational analysis of coupled blood-wall arterial LDL transport, J. Biomech.”
MethodInfluentialGessaghi, V. C., Raschi, M., Tanoni, D. Y., Perazzo, C. A., & Larreteguy, A. E. (2011) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2011.03.001 · Cited by 20
“This is why, lately, some researchers simulated coupled transport of LDL both in the lumen and through the artery wall [17,18].”
BackgroundBoundary layer considerations in a multi-layer model for LDL accumulation
Iasiello, M., Kambiz Vafai, B., Andreozzi, A., & Bianco, N. D. (2018) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2018.1521963 · Cited by 20
Kim, S., & Giddens, D. P. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4028969 · Cited by 19
“The interstitial flow, which convects LDL particles into the subendothelial layer and within vessel wall, is calculated with Darcy’s model [15] or Brinkman’s model [13,16] to obtain detailed transport of the solute based on single-layer or multilayer models.”
MethodNumerical and experimental LDL transport through arterial wall
Filipović, N., Živić, M. Ž., Obradović, M., Djukic, T. R., Marković, Z., & Rosic, M. A. (2013) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1238-1 · Cited by 19
“A more realistic approach is used in lumen-wall models, where there is a coupling of the transport within the lumen and the wall (Moore and Ethier 1997; Stangeby and Ethier 2002a, b).”
BackgroundMethodModal analysis and testing of a thin-walled gradient coil cylinder model
Wang, F., & Mechefske, C. K. (2005) · Concepts in Magnetic Resonance Part B · doi:10.1002/cmr.b.20045 · Cited by 19
Mackerle, J. (2005) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840500141486 · Cited by 25
Wang, L., Korossis, S., Ingham, E., Fisher, J., & Jin, Z. M. (2008) · PubMed · Cited by 18
Blood flow and macromolecular transport in complex blood vessels
Hong, J., Wei, L., Fu, C., & Tan, W. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.07.006 · Cited by 18
“75 s) as in reference (Stangeby and Ethier, 2002).”
Vincent, P., Sherwin, S. J., & Weinberg, P. D. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.01.022 · Cited by 18
Mass transfer to blood flowing through arterial stenosis
Sarifuddin, S., Chakravarty, S., Mandal, P. K., & Andersson, H. I. (2008) · Zeitschrift für angewandte Mathematik und Physik · doi:10.1007/s00033-008-7094-2 · Cited by 17
“This feature is well agreed with the observation of Stangeby and Ethier [ 25 ].”
ResultEffect of Transmural Transport Properties on Atheroma Plaque Formation and Development
Cilla, M., Martínez, M. Á., & Peña, E. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1299-2 · Cited by 17
Non-Newtonian effects on low-density lipoprotein transport in the arterial wall
Hong, J., Fu, C., Lin, H., & Tan, W. (2012) · Journal of Non-Newtonian Fluid Mechanics · doi:10.1016/j.jnnfm.2012.09.008 · Cited by 16
Modeling cholesterol metabolism and atherosclerosis
Auley, M. T. M. (2021) · WIREs Mechanisms of Disease · doi:10.1002/wsbm.1546 · Cited by 17
Stark, J. R., Gorman, J. M., Sparrow, E. M., Abraham, J., & Kohler, R. E. (2013) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2013.65067 · Cited by 15
“Tissue permeability 2 × 10 m(2) [5,17-18] a high viscosity fluid and a shorter therapy duration.”
BackgroundComputer simulation of three-dimensional plaque formation and progression in the coronary artery
Filipović, N., Nikolić, D. D., Saveljic, I. B., Milošević, Ž., Exarchos, T. P., Pelosi, G., & Parodi, O. (2013) · Computers & Fluids · doi:10.1016/j.compfluid.2013.07.006 · Cited by 15
Alimohamadi, H., & Imani, M. (2014) · International Journal for Computational Methods in Engineering Science and Mechanics · doi:10.1080/15502287.2014.915253 · Cited by 15
“Stangeby and Ethier [7] worked out a coupling model of Navier-Stokes and Brinkman equations in free and porous media.”
MethodPatient-specific arterial system flow oscillation.
Fytanidis, D., Soulis, J., & Giannoglou, G. (2014) · Europe PMC (PubMed Central) · Cited by 18
Macromolecular Transport in Arterial Walls: Current and Future Directions
Khanafer, K., & Kambiz Vafai, B. (2008) · Springer eBooks · doi:10.1007/978-1-4020-8178-1_9 · Cited by 13
Yoshihara, L., Coroneo, M., Comerford, A., Bauer, G., Klöppel, T., & Wall, W. A. (2014) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.4735 · Cited by 13
Determination of atherosclerotic plaque temperature in large arteries
Ley, O., & Kim, T. (2007) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2007.01.034 · Cited by 13
Effect of transport parameters on atherosclerotic lesion growth: A parameter sensitivity analysis
Piemjaiswang, R., Ding, Y., Feng, Y., Piumsomboon, P., & Chalermsinsuwan, B. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105904 · Cited by 12
Effect of arterial curvature on hemodynamics and mass transport
Lu, S., & Zhang, S. (2019) · Biorheology · doi:10.3233/bir-190215 · Cited by 12
“Previous studies showed that a high permeability of lipids into artery wall and an elevated lipid concentration at the wall may directly cause accelerated development of atherosclerosis [18,40].”
InfluentialAmeenuddin, M., & Anand, M. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4047426 · Cited by 12
Physiology and Pathophysiology of Microcirculation
Thiriet, M. (2015) · Springer eBooks · doi:10.1007/978-3-642-37078-6_24 · Cited by 11
Numerical methods for a fluid mixture model
Wang, Q., Lin, S., & Zhang, Z. (2012) · International Journal for Numerical Methods in Fluids · doi:10.1002/fld.3639 · Cited by 10
Numerical Modeling of Blood Flow in Irregular Stenosed Artery with the Effects of Gravity
Tan, B., & Mustapha, N. (2013) · Jurnal Teknologi · doi:10.11113/jt.v62.1889 · Cited by 10
“It is provided with evidence by studies of Rappitsch and Perktold [21] and Stangeby and Eithier [22] as: 2 0 2 ( , , ) 2 1 r w r z t U R , ( , , ) 0u r z t for 0z (9) At downstream, the velocity is treated to be zero.”
MethodSoulis, J. V., Fytanidis, D. K., Lampri, O. P., & Giannoglou, G. D. (2016) · Cardiology Research · doi:10.14740/cr467w · Cited by 10
“Previous investigations [24] indicate that the flow pattern is crucial for plaque formation.”
BackgroundApplications of porous media in biological transport modeling
Khanafer, K., & Kambiz Vafai, B. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-85740-6.00014-5 · Cited by 9
Ding, Z., Fan, Y., Deng, X., Sun, A., & Kang, H. (2010) · Experimental Biology and Medicine · doi:10.1258/ebm.2010.010035 · Cited by 9
Buckling of adaptive elastic bone-plate: theoretical and numerical investigation
Ramtani, S., & Abdi, M. (2005) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-004-0056-5 · Cited by 10
Tissue–fluid interface analysis using biphasic finite element method
Unnikrishnan, G. U., Unnikrishnan, V. U., & Reddy, J. N. (2008) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840802372045 · Cited by 9
Concentration of blood-borne agonists at the endothelium
Plank, M. J., Comerford, A., David, T., & Wall, D. J. N. (2005) · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rspa.2005.1591 · Cited by 9
“In addition, blood-borne macromolecules such as lipoproteins are transported from the bloodstream to the arterial intima via trans-endothelial filtration (Phelps & DePaola 2000; Stangeby & Ethier 2002).”
BackgroundMethodAlimohamadi, H., Imani, M., & Shojaeizadeh, M. (2014) · Cited by 8
Numerical Analysis of the Cooling Effect of Blood Over Inflamed Atherosclerotic Plaque
Kim, T., & Ley, O. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2913236 · Cited by 7
Oxygen Mass Transport in Stented Coronary Arteries
Murphy, E. A., Dunne, A. S., Martin, D. M., & Boyle, F. J. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1501-6 · Cited by 7
Karimi, S., Dadvar, M., Modarress, H., & Dabir, B. (2013) · Chemistry and Physics of Lipids · doi:10.1016/j.chemphyslip.2013.07.006 · Cited by 7
Modal analysis of a multilayered gradient coil insert in a 4‐T MRI scanner
Wang, F., & Mechefske, C. K. (2007) · Concepts in Magnetic Resonance Part B · doi:10.1002/cmr.b.20097 · Cited by 6
Assessing factors of endothelial vascular dysfunction in patients with primary open-angle glaucoma
Dusmukhamedova, A. M., Tuychibaeva, D. M., & Хаджиметов, А. А. (2022) · Oftalmologicheskii Zhurnal · doi:10.31288/oftalmolzh202261418 · Cited by 6
Banerjee, R. K., Kwon, O., Vaidya, V. S., & BACK, L. H. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.011 · Cited by 6
“Stangeby and Ethier (2002), in a recent numerical study, also reported that the mass flux to the wall increases in the acceleration region and decreases in the deceleration region reaching the minimum at the point of flow separation.”
BackgroundAlimohamadi, H., & Sadeghy, K. (2015) · Nihon Reoroji Gakkaishi · doi:10.1678/rheology.43.135 · Cited by 6
Blood flow and macromolecular transport in curved blood vessels
Wei, L., Wen, G.-B., & Tan, W. (2006) · Applied Mathematics and Mechanics · doi:10.1007/s10483-006-0909-y · Cited by 6
Hyperthermia applications in cardiovascular and cancer therapy treatments
Imanlou, S., & Kambiz Vafai, B. (2024) · Advances in heat transfer · doi:10.1016/bs.aiht.2024.02.002 · Cited by 5
Oscillating shear index, wall shear stress and low density lipoprotein accumulation in human RCAs
Soulis, J. V., Fytanidis, D., Papaioannou, V., Giannoglou, G., & Micro, R. (2011) · Brunel University Research Archive (BURA) (Brunel University London) · Cited by 5
Fluid-Structure Interaction Analysis for Drug Transport in a Curved Stenotic Right Coronary Artery
Park, S. (2016) · Journal of Biosciences and Medicines · doi:10.4236/jbm.2016.45011 · Cited by 5
“utilized low density lipoprotein (LDL), which is one of the major causes for stenosis, to examine the mass transfer in a stenotic artery [11].”
Method
Metadata
- Authors
- Stangeby, D. K., & Ethier, C. R.
- Affiliations
- University of Toronto (CA)
- ORCID
- Ethier, C. Ross
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2001-09-17
- Volume
- 124
- Issue
- 1
- Pages
- 1-8
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2064998967
- Cited by
- 154
- References
- 64
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 2 · 2023: 2 · 2022: 5 · 2021: 2 · 2020: 5 · 2019: 5 · 2018: 6 · 2017: 3 · 2016: 3 · 2015: 11 · 2014: 10 · 2013: 13 · 2012: 7
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Life Sciences › Immunology and Microbiology › Immunology › Atherosclerosis and Cardiovascular Diseases
- Physical Sciences › Engineering › Computational Mechanics › Advanced Numerical Methods in Computational Mathematics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Coronary Interventions and Diagnostics
- Keywords
- arterial wall, atherogenesis, stenosed artery, Brinkman model, porous media flow, vasa vasorum, wall permeability, convection-dominated diffusion, atherosclerotic plaque
- MeSH terms
- Arteries, Arteriosclerosis, Biological Transport, Cell Membrane Permeability, Computer Simulation, Constriction, Pathologic, Endothelium, Vascular, Hemodynamics, Humans, Lipoproteins, LDL, Models, Cardiovascular, Oxygen, Pressure, Rheology, Sensitivity and Specificity, Porosity, Finite Element Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.