The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Computational Analysis of Coupled Blood-Wall Arterial LDL Transport
Abstract
The transport of macromolecules, such as low density lipoproteins (LDLs), across the artery wall and their accumulation in the wall is a key step in atherogenesis. Our objective was to model fluid flow within both the lumen and wall of a constricted, axisymmetric tube simulating a stenosed artery, and to then use this flow pattern to study LDL mass transport from the blood to the artery wall. Coupled analysis of lumenal blood flow and transmural fluid flow was achieved through the solution of Brinkman’s model, which is an extension of the Navier-Stokes equations for porous media. This coupled approach offers advantages over traditional analyses of this problem, which have used possibly unrealistic boundary conditions at the blood-wall interface; instead, we prescribe a more natural pressure boundary condition at the adventitial vasa vasorum, and allow variations in wall permeability due to the occurrence of plaque. Numerical complications due to the convection dominated mass transport process (low LDL diffusivity) are handled by the streamline upwind/Petrov-Galerkin (SUPG) finite element method. This new fluid-plus-porous-wall method was implemented for conditions typical of LDL transport in a stenosed artery with a 75 percent area reduction (Peclet number=2×108). The results show an elevated LDL concentration at the downstream side of the stenosis. For the higher Darcian wall permeability thought to occur in regions containing atheromatous lesions, this leads to an increased transendothelial LDL flux downstream of the stenosis. Increased transmural filtration in such regions, when coupled with a concentration-dependent endothelial permeability to LDL, could be an important contributor to LDL infiltration into the arterial wall. Experimental work is needed to confirm these results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Microfluidic perfusion models that are used to model early stage atherosclerosis and later thrombosis have a significant potential in drug development [291–294].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [294]
Citations
Cites
Brooks, A. N., & Hughes, T. J. R. (1982) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(82)90071-8 · Cited by 5,332
The Low-Density Lipoprotein Pathway and its Relation to Atherosclerosis
Goldstein, L. J., & Brown, S. M. (1977) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.46.070177.004341 · Cited by 1,906
Zarins, C. K., Giddens, D. P., Bharadvaj, B. K., Sottiurai, V. S., Mabon, R. F., & Glagov, S. (1983) · Circulation Research · doi:10.1161/01.res.53.4.502 · Cited by 1,485
Caro, C. G., Fitz-Gerald, J. M., & Schroter, R. C. (1971) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1971.0019 · Cited by 1,357
Physicochemical hydrodynamics: an introduction
(1995) · Choice Reviews Online · doi:10.5860/choice.32-3319 · Cited by 878
Flow patterns and spatial distribution of atherosclerotic lesions in human coronary arteries.
Asakura, T., & Karino, T. (1990) · Circulation Research · doi:10.1161/01.res.66.4.1045 · Cited by 856
Gown, A. M., Tsukada, T., & Ross, R. (1986) · PubMed · Cited by 676
Neale, G., & Nader, W. (1974) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450520407 · Cited by 556
The Role of Fluid Mechanics in the Localization and Detection of Atherosclerosis
Giddens, D. P., Zarins, C. K., & Glagov, S. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895545 · Cited by 490
FLOW THROUGH INTERSTITIUM AND OTHER FIBROUS MATRICES
Levick, J. R. (1987) · Quarterly Journal of Experimental Physiology · doi:10.1113/expphysiol.1987.sp003085 · Cited by 480
Microscopic flow near the surface of two-dimensional porous media. Part 1. Axial flow
Larson, R. E., & Higdon, J. J. L. (1986) · Journal of Fluid Mechanics · doi:10.1017/s0022112086000228 · Cited by 264
On the interaction between polysaccharides and other macromolecules
Laurent, T. C., Björk, I., Pietruszkiewicz, A., & Persson, H. (1963) · Biochimica et Biophysica Acta · doi:10.1016/0006-3002(63)91645-7 · Cited by 223
Microscopic flow near the surface of two-dimensional porous media. Part 2. Transverse flow
Larson, R. E., & Higdon, J. J. L. (1987) · Journal of Fluid Mechanics · doi:10.1017/s0022112087001149 · Cited by 198
Wang, D. M., & Tarbell, J. M. (1995) · Journal of Biomechanical Engineering · doi:10.1115/1.2794192 · Cited by 188
Filtration through damaged and undamaged rabbit thoracic aorta
Tedgui, A., & Lever, M. J. (1984) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1984.247.5.h784 · Cited by 187
Sprague, E. A., Steinbach, B. L., Nerem, R. M., & Schwartz, C. J. (1987) · Circulation · doi:10.1161/01.cir.76.3.648 · Cited by 171
Endothelial albumin permeability is shear dependent, time dependent, and reversible
Jo, H., Dull, R. O., Hollis, T. M., & Tarbell, J. M. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.260.6.h1992 · Cited by 168
Distribution of Inflammatory Cells in Atherosclerotic Plaques Relates to the Direction of Flow
Dirksen, M. T., van der Wal, A. C., van den Berg, F. M., van der Loos, C. M., & Becker, A. E. (1998) · Circulation · doi:10.1161/01.cir.98.19.2000 · Cited by 166
Principles and models of biological transport
(1988) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(88)90180-2 · Cited by 147
Deng, X., Marois, Y., How, T. V., Merhi, Y., King, M. W., Guidoin, R., & Karino, T. (1995) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(95)70252-0 · Cited by 130
Transport of 14 C-4-Cholesterol between Serum and Wall in the Perfused Dog Common Carotid Artery
CARO, C. G., & Nerem, R. M. (1973) · Circulation Research · doi:10.1161/01.res.32.2.187 · Cited by 125
Oxygen Mass Transfer Calculations in Large Arteries
Moore, J. A., & Ethier, C. R. (1997) · Journal of Biomechanical Engineering · doi:10.1115/1.2798295 · Cited by 120
Self-citationThe effect of hyaluronic acid on the sedimentation rate of other substances
Laurent, T. C., & Pietruszkiewicz, A. (1961) · Biochimica et Biophysica Acta · doi:10.1016/0006-3002(61)90125-1 · Cited by 119
Numerical simulation of mass transfer in porous media of blood vessel walls
Huang, Z. J., & Tarbell, J. M. (1997) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1997.273.1.h464 · Cited by 108
Computer simulation of convective diffusion processes in large arteries
Rappitsch, G., & Perktold, K. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00045-3 · Cited by 97
Spatial variations in endothelial barrier function in disturbed flows in vitro
Phelps, J. E., & DePaola, N. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.2.h469 · Cited by 97
Pulsatile Albumin Transport in Large Arteries: A Numerical Simulation Study
Rappitsch, G., & Perktold, K. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796038 · Cited by 95
A Numerical Simulation of Flow in a Two-Dimensional End-to-Side Anastomosis Model
Steinman, D. A., Vinh, B., Ethier, C. R., Ojha, M., Cobbold, R. S. C., & Johnston, K. W. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895457 · Cited by 89
Self-citationLocalization patterns of plasma apolipoproteins in human atherosclerotic lesions.
Hoff, H. F., Heideman, C. L., Jackson, R. L., Bayardo, R. J., Kim, H. S., & Gotto, A. M. (1975) · Circulation Research · doi:10.1161/01.res.37.1.72 · Cited by 89
Do Plaques Grow Upstream or Downstream? An Angiographic Study in the Femoral Artery
Smedby, Ö. (1997) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.17.5.912 · Cited by 81
Hemodynamics and the vascular endothelial cytoskeleton.
Herman, I. M., Brant, A. M., WARTY, V. S., Bonaccorso, J., Klein, E. C., Kormos, R. L., & Borovetz, H. S. (1987) · The Journal of Cell Biology · doi:10.1083/jcb.105.1.291 · Cited by 77
A New View of Convective-Diffusive Transport Processes in the Arterial Intima
Yuan, F., Chien, S., & Weinbaum, S. (1991) · Journal of Biomechanical Engineering · doi:10.1115/1.2894890 · Cited by 76
Convective mass transfer at the carotid bifurcation
Ma, P., Li, X., & Ku, D. N. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)84506-x · Cited by 72
Principles and Models of Biological Transport
Friedman, M. H. (1986) · Springer eBooks · doi:10.1007/978-3-662-02467-6 · Cited by 70
Ultrafiltration of lipoproteins through a synthetic membrane
Colton, C. K., Friedman, S., Wilson, D. E., & Lees, R. S. (1972) · Journal of Clinical Investigation · doi:10.1172/jci107061 · Cited by 69
Guretzki, H.-J., Gerbitz, K.-D., Olgemöller, B., & Schleicher, E. D. (1994) · Atherosclerosis · doi:10.1016/0021-9150(94)90137-6 · Cited by 62
Truskey, G. A., Roberts, W. L., Herrmann, R. A., & Malinauskas, R. A. (1992) · Circulation Research · doi:10.1161/01.res.71.4.883 · Cited by 62
Curmi, P. A., Juan, L., & Tedgui, A. (1990) · Circulation Research · doi:10.1161/01.res.66.6.1692 · Cited by 60
THE COMPARATIVE FILTRATION PROPERTIES OF EXCISED ARTERIES AND VEINS
Wilens, S. L., & McCluskey, R. T. (1952) · The American Journal of the Medical Sciences · doi:10.1097/00000441-195211000-00009 · Cited by 57
Baldwin, A. L., Wilson, L. M., Gradus‐Pizlo, I., Wilensky, R. L., & March, K. L. (1997) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.17.12.3365 · Cited by 52
Hf, H., Jl, T., Bayardo, R. J., Jackson, R. L., Gotto, A. M., DEBAKEY, M. E., & Lie, J. T. (1975) · PubMed · Cited by 52
Flow through mixed fibrous porous materials
Ethier, C. R. (1991) · AIChE Journal · doi:10.1002/aic.690370812 · Cited by 51
Self-citationLabadie, R. F., Antaki, J. F., Williams, J. L., Katyal, S. L., Ligush, J., Watkins, S. C., Pham, S. M., & Borovetz, H. S. (1996) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1996.270.2.h760 · Cited by 49
Macromolecular Transport Through the Deformable Porous Media of an Artery Wall
Kim, W., & Tarbell, J. M. (1994) · Journal of Biomechanical Engineering · doi:10.1115/1.2895714 · Cited by 46
The Effect of Aging and Pressure on the Specific Hydraulic Conductivity of the Aortic Wail
Whale, M., Grodzinsky, A. J., & Johnson, M. (1996) · Biorheology · doi:10.1016/0006-355x(96)00003-0 · Cited by 37
Gan, L., Sjögren, L. S., Doroudi, R., & Jern, S. (1999) · Journal of Vascular Research · doi:10.1159/000025627 · Cited by 36
A device for the application of cyclic twist and extension on perfused vascular segments
Vorp, D. A., Severyn, D., Steed, D. L., & Webster, M. W. (1996) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1996.270.2.h787 · Cited by 36
Effect of spatial variations in shear on diffusion at the wall of an arterial branch.
Friedman, M. H., & Ehrlich, L. W. (1975) · Circulation Research · doi:10.1161/01.res.37.4.446 · Cited by 35
Probstein, R. F. (1989) · Elsevier eBooks · doi:10.1016/b978-0-409-90089-7.50007-8 · Cited by 34
Significance of luminal plasma layer resistance in arterial wall oxygen supply.
Schneiderman, G., & Goldstick, T. K. (1978) · Atherosclerosis · doi:10.1016/0021-9150(78)90032-1 · Cited by 31
BACK, L. H. (1975) · Mathematical Biosciences · doi:10.1016/0025-5564(75)90105-4 · Cited by 30
Caro, C. G. (1974) · Cardiovascular Research · doi:10.1093/cvr/8.2.194 · Cited by 26
McIntire, L. V., Wagner, J. E., Papadaki, M., Whitson, P. A., & Eskin, S. G. (1998) · Biological Bulletin · doi:10.2307/1543123 · Cited by 22
Quantitative analysis of blood vessel permeability of squirrel monkeys
Tompkins, R. G. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.260.4.h1194 · Cited by 22
Deng, X., King, M. W., & Guidoin, R. (1995) · ASAIO Journal · doi:10.1097/00002480-199501000-00010 · Cited by 21
Karmakar, N., & Dhar, P. (1996) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.1996.tb02827.x · Cited by 15
The specific hydraulic conductivity of bovine serum albumin
Kim, A., Wang, C., Johnson, M., & Kamm, R. D. (1991) · Biorheology · doi:10.3233/bir-1991-28504 · Cited by 12
André, P., Sollier, C. B. D., Bonneau, M., Pignaud, G., Hainaud, P., Azzam, K., & Drouet, L. O. (2009) · Haemostasis · doi:10.1159/000217286 · Cited by 11
Deng, X., King, M. W., & Guidoin, R. (1995) · ASAIO Journal · doi:10.1097/00002480-199541010-00010 · Cited by 11
Neumann, S. J., Berceli, S. A., Sevick, E., Lincoff, A. M., WARTY, V. S., Brant, A. M., Herman, I. M., & Borovetz, H. S. (1990) · Bulletin of Mathematical Biology · doi:10.1007/bf02460805 · Cited by 10
Cg, C. (1973) · PubMed · Cited by 8
Mandarino, W. A., Berceli, S. A., Sheppeck, R. A., & Borovetz, H. S. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90034-x · Cited by 7
Numerical modeling of mass transport in the arterial wall
Karner, G., & Perktold, K. (1999) · Cited by 5
Kim, A., Wang, C. H., Johnson, M., & Kamm, R. D. (1992) · Biorheology · Cited by 2
Research works printed but not linked: 5
- Stangeby, D. K., and Ethier, C. R., 2000, “Computational analysis of convection dominated transport in two media: arterial mass transport,” Proceedings, Conference on Mathematical Modeling and Scientific Computing.
- Ethier, C. R., Steinman, D. A., and Ojha, M., 1999, “Comparisons between computational hemodynamics, photochromic dye flow visualization and magnetic resonance velocimetry,” Haemodynamics of Arterial Organs. X. Y. Xu and M. W. Collins, eds., WIT Press, Southampton, pp. 131–183.
- Wada, S., and Karino, T., 1999, “Relationship between wall shear stress and surface concentration of lipoproteins calculated for a multiple bend of the human right coronary artery,” V. K. Goel et al., eds., Proceedings, 1999 Bioengineering Conference, BED Vol. 42, ASME Press, New York, pp. 735–736.
- Steinman, D. A., 1993, “Numerical Analysis of Flow in a 2-D Distensible Model of an End-to-Side Anastomosis,” Ph.D. thesis, University of Toronto.
- Fatouraec, N., Deng, X., De Champlain, A., and Guidoin, R., 1999, “Numerical simulation of lipid transport through arterial stenoses,” V. K. Goel et al., eds., Proceedings, 1999 Bioengineering Conference, BED Vol. 42, ASME Press, New York, pp. 733–734.
Cited by
Applied Mathematical Modelling
Breusers, H. N. C. (1976) · Journal of Hydraulic Research · doi:10.1080/00221687609499673 · Cited by 288
Cardiovascular disease models: A game changing paradigm in drug discovery and screening
Savoji, H., Mohammadi, M. H., Rafatian, N., Toroghi, M. K., Wang, E. Y., Zhao, Y., Korolj, A., Ahadian, S., & Radisic, M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.036 · Cited by 223
Modeling of low-density lipoprotein (LDL) transport in the artery—effects of hypertension
Yang, N., & Kambiz Vafai, B. (2005) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.09.019 · Cited by 198
“Stangeby and Ethier [6] have cited that the estimated endothelial LDL diffusive permeability at 160 mmHg is four times greater interface based upon the different values of the lumen outlet pressure. endothelium interface for the steady flow model based upon the different than the value measured at normal vascular pres…”
BackgroundMethodInfluentialA coupling model for macromolecule transport in a stenosed arterial wall
Ai, L., & Kambiz Vafai, B. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.10.041 · Cited by 197
“The third factor is that the permeability of the wall may be pressure dependent [8].”
BackgroundInfluentialProsi, M., Zunino, P., Perktold, K., & Quarteroni, A. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.04.024 · Cited by 187
Metadata
- Authors
- Stangeby, D. K., & Ethier, C. R.
- Affiliations
- University of Toronto (CA)
- ORCID
- Ethier, C. Ross
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2001-09-17
- Volume
- 124
- Issue
- 1
- Pages
- 1-8
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2064998967
- Cited by
- 154
- References
- 64
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 2 · 2023: 2 · 2022: 5 · 2021: 2 · 2020: 5 · 2019: 5 · 2018: 6 · 2017: 3 · 2016: 3 · 2015: 11 · 2014: 10 · 2013: 13 · 2012: 7
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Life Sciences › Immunology and Microbiology › Immunology › Atherosclerosis and Cardiovascular Diseases
- Physical Sciences › Engineering › Computational Mechanics › Advanced Numerical Methods in Computational Mathematics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Coronary Interventions and Diagnostics
- Keywords
- arterial wall, atherogenesis, stenosed artery, Brinkman model, porous media flow, vasa vasorum, wall permeability, convection-dominated diffusion, atherosclerotic plaque
- MeSH terms
- Arteries, Arteriosclerosis, Biological Transport, Cell Membrane Permeability, Computer Simulation, Constriction, Pathologic, Endothelium, Vascular, Hemodynamics, Humans, Lipoproteins, LDL, Models, Cardiovascular, Oxygen, Pressure, Rheology, Sensitivity and Specificity, Porosity, Finite Element Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.