The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Recruitment of Tendon Crimp With Applied Tensile Strain
Abstract
The tensile stress-strain behavior of ligaments and tendons begins with a toe region that is believed to result from the straightening of crimped collagen fibrils. The in situ mechanical function is mostly confined to this toe region and changes in crimp morphology are believed to be associated with pathological conditions. A relatively new imaging technique, optical coherence tomography (OCT), provides a comparatively inexpensive method for nondestructive investigation of tissue ultrastructure with resolution on the order of 15 μm and the potential for use in a clinical setting. The objectives of this work were to assess the utility of OCT for visualizing crimp period, and to use OCT to determine how crimp period changed as a function of applied tensile strain in rat tail tendon fascicles. Fascicles from rat tail tendons were subjected to 0.5 percent strain increments up to 5 percent and imaged at each increment using OCT. A comparison between OCT images and optical microscopy images taken between crossed polarizing lenses showed a visual correspondence between features indicative of crimp pattern. Crimp pattern always disappeared completely before 3 percent axial strain was reached. Average crimp period increased as strain increased, but both elongation and shortening occurred within single crimp periods during the application of increasing strain to the fascicle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
In vivo ultrahigh-resolution optical coherence tomography
Drexler, W., Morgner, U., Käertner, F. X., Pitris, C., Boppart, S. A., Li, X. D., Ippen, E. P., & Fujimoto, J. G. (1999) · Optics Letters · doi:10.1364/ol.24.001221 · Cited by 945
de Boer, J. F., Milner, T. E., van Gemert, M. J. C., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000934 · Cited by 883
The Multicomposite Structure of Tendon
Kastelic, J., Galeski, A., & Baer, E. (1978) · Connective Tissue Research · doi:10.3109/03008207809152283 · Cited by 689
Collagen; ultrastructure and its relation to mechanical properties as a function of ageing
Diamant, J., Keller, A., Baer, E., Litt, M., & Arridge, R. G. C. (1972) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1972.0019 · Cited by 553
The Mechanical Properties of Rat Tail Tendon
Rigby, B. J., Hirai, N., Spikes, J. D., & Eyring, H. (1959) · The Journal of General Physiology · doi:10.1085/jgp.43.2.265 · Cited by 482
Magnetic resonance myocardial fiber-orientation mapping with direct histological correlation
Hsu, E. W., Muzikant, A. L., Matulevicius, S. A., Penland, R. C., & Henriquez, C. S. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.5.h1627 · Cited by 386
In vitro andin vivo Raman spectroscopy of human skin
Caspers, P. J., Lucassen, G. W., Wolthuis, R., Bruining, H. A., & Puppels, G. J. (1998) · Biospectroscopy · doi:10.1002/(sici)1520-6343(1998)4:5+<s31::aid-bspy4>3.0.co;2-m · Cited by 314
A small angle light scattering device for planar connective tissue microstructural analysis
Sacks, M. S., Smith, D. B., & Hiester, E. D. (1997) · Annals of Biomedical Engineering · doi:10.1007/bf02684845 · Cited by 295
Subsurface Imaging of Living Skin with Optical Coherence Microscopy
Schmitt, J. M., Yadlowsky, M. J., & Bonner, R. F. (1995) · Dermatology · doi:10.1159/000246523 · Cited by 251
Cited by
Bohm, S., Mersmann, F., & Arampatzis, A. (2015) · Sports Medicine - Open · doi:10.1186/s40798-015-0009-9 · Cited by 458
Collagen Structure of Tendon Relates to Function
Franchi, M., Trirè, A., Quaranta, M., Orsini, E., & Ottani, V. (2007) · The Scientific World JOURNAL · doi:10.1100/tsw.2007.92 · Cited by 349
The materials science of collagen
Sherman, V. R., Yang, W., & Meyers, M. A. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.05.023 · Cited by 324
Lynch, H. A., Johannessen, W., Wu, J. P., Jawa, A., & Elliott, D. M. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1614819 · Cited by 272
Constitutive modeling of crimped collagen fibrils in soft tissues
Grytz, R., & Meschke, G. (2009) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2008.12.009 · Cited by 160
Metadata
- Authors
- Hansen, K. A., Weiss, J. A., & Barton, J. K.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2001-08-16
- Volume
- 124
- Issue
- 1
- Pages
- 72-77
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2140887772
- Cited by
- 285
- References
- 15
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recruitment of Tendon Crimp With Applied Tensile Strain. https://app.cochat.ai/papers/10.1115/1.1427698
- The paper
- Hansen, K. A., Weiss, J. A., & Barton, J. K. (2002). Recruitment of Tendon Crimp With Applied Tensile Strain. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.1427698
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.