CoChat
Cited by 360

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Numerical Simulation of Airflow in the Human Nasal Cavity

Keyhani, K., Scherer, P. W., Mozell, M. M. · 1995 · Journal of Biomechanical Engineering

Abstract

An anatomically correct finite element mesh of the right human nasal cavity was constructed from CAT scans of a healthy adult nose. The steady-state Navier-Stokes and continuity equations were solved numerically to determine the laminar airflow patterns in the nasal cavity at quiet breathing flow rates. In the main nasal passages, the highest inspiratory air speed occurred along the nasal floor (below the inferior turbinate), and a second lower peak occurred in the middle of the airway (between the inferior and middle turbinates and the septum). Nearly 30 percent of the inspired volumetric flow passed below the inferior turbinate and about 10 percent passed through the olfactory airway. Secondary flows were induced by curvature and rapid changes in cross-sectional area of the airways, but the secondary velocities were small in comparison with the axial velocity through most of the main nasal passages. The flow patterns changed very little as total half-nasal flow rate varied between resting breathing rates of 125 m/s and 200 ml/s. During expiration, the peaks in velocity were smaller than inspiration, and the flow was more uniform in the turbinate region. Inspiratory streamline patterns in the model were determined by introducing neutrally buoyant point particles at various locations on the external naris plane, and tracking their path based on the computed flow field. Only the stream from the ventral tip of the naris reached the olfactory airway. The numerically computed velocity field was compared with the experimentally measured velocity field in a large scale (20×) physical model, which was built by scaling up from the same CAT scans. The numerical results showed good agreement with the experimental measurements at different locations in the airways, and confirmed that at resting breathing flow rates, airflow through the nasal cavity is laminar.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.2794204

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

Metadata

Authors
Keyhani, K., Scherer, P. W., & Mozell, M. M.
Venue
Journal of Biomechanical Engineering
Published
1995-11-01
Volume
117
Issue
4
Pages
429-441
ISSN
  • 0148-0731 (ISSN-L)
  • 1528-8951
OpenAlex
W2076074467
Cited by
360
References
14
FWCI
4.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.