Application of the Tsai–Wu Quadratic Multiaxial Failure Criterion to Bovine Trabecular Bone
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
As a first step toward development of a multiaxial failure criterion for human trabecular bone, the Tsai–Wu quadratic failure criterion was modified as a function of apparent density and applied to bovine tibial trabecular bone. Previous data from uniaxial compressive, tensile, and torsion tests (n = 139 total) were combined with those from new triaxial tests (n = 17) to calibrate and then verify the criterion. Combinations of axial compression and radial pressure were used to produce the triaxial compressive stress states. All tests were performed with minimal end artifacts in the principal material coordinate system of the trabecular network. Results indicated that the stress interaction term F12 exhibited a strong nonlinear dependence on apparent density (r2 > 0.99), ranging from −0.126 MPa−2 at low densities (0.29 g/cm3) to 0.005 MPa−2 at high densities (0.63 g/cm3). After calibration and when used to predict behavior of new specimens without any curve-fitting, the Tsai–Wu criterion had a mean (± SD) error of −32.6 ± 10.6 percent. Except for the highest density triaxial specimens, most (15/17 specimens) failed at axial stresses close to their predicted uniaxial values, and some reinforcement for transverse loading was observed. We conclude that the Tsai–Wu quadratic criterion, as formulated here, is at best only a reasonable predictor of the multiaxial failure behavior of trabecular bone, and further work is required before it can be confidently applied to human bone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401
Silva, M. J., & Gibson, L. J. (1997) · International Journal of Mechanical Sciences · doi:10.1016/s0020-7403(96)00065-3 · Cited by 364
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationAnisotropic yield behavior of bone under combined axial force and torque
Cezayirlioglu, H., Bahniuk, E., Davy, D. T., & Heiple, K. G. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90045-4 · Cited by 164
Fabric dependence of an anisotropic strength criterion
Cowin, S. C. (1986) · Mechanics of Materials · doi:10.1016/0167-6636(86)90022-0 · Cited by 87
Cited by
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Self-citationBiomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Modelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
“Other authors have tried to validate experimental tests using cellular solid multiaxial criteria [123,127].”
BackgroundMethodNiebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431
Self-citationNazarian, A., von Stechow, D., Zurakowski, D., Müller, R., & Snyder, B. D. (2008) · Calcified Tissue International · doi:10.1007/s00223-008-9174-x · Cited by 244
“demonstrated that, similar to compression, the shear and tensile properties of cancellous bone depend on BMD [55, 56].”
BackgroundLevrero-Florencio, F., Margetts, L., Sales, E., Xie, S., Manda, K., & Pankaj, P. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.04.008 · Cited by 46
“There have, however, been some attempts to on trabecular bone wherein the loading cases have been limited to triaxial compression (Keaveny et al., 1999; Rincon-Kohli and Zysset, 2009).”
An Alternative Fabric-based Yield and Failure Criterion for Trabecular Bone
Zysset, P., & Rincón, L. (2006) · Mechanics of Biological Tissue · doi:10.1007/3-540-31184-x_33 · Cited by 39
Metadata
- Authors
- Keaveny, T. M., Wachtel, E. F., Zadesky, S. P., & Arramon, Y. P.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1999-02-01
- Volume
- 121
- Issue
- 1
- Pages
- 99-107
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2108751875
- Cited by
- 80
- References
- 6
- FWCI
- 3.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.