Investigations on Multisensor-Based Noninvasive Blood Glucose Measurement System
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Noninvasive blood glucose (NIBG) measurement technique has been explored for the last three decades to facilitate diabetes management. Photoplethysmogram (PPG) signal may be used to measure the variations in blood glucose concentration. However, the literature reveals that physiological perturbations such as temperature, skin moisture, and sweat lead to less accurate NIBG measurements. The task of minimizing the effect of these perturbations for accurate measurements is an important research area. Therefore, in the present work, galvanic skin response (GSR) and temperature measurements along with PPG were used to measure blood glucose noninvasively. The data extracted from the sensors were used to estimate blood glucose concentration with the help of two machine learning (ML) techniques, i.e., multiple linear regression (MLR) and artificial neural network (ANN). The accuracy of proposed multisensor system was evaluated by pairing and comparing noninvasive measurements with invasively measured readings. The study was performed on 50 nondiabetic subjects with body mass index (BMI) 27.3 ± 3 kg/m2. The results revealed that multisensor NIBG measurement system significantly improves mean absolute prediction error and correlation coefficient in comparison to the techniques reported in the literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis and classification of diabetes mellitus
American Diabetes Association (2009) · Diabetes Care · doi:10.2337/dc09-s062 · Cited by 1,817
Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm
Troy, T. L., & Thennadil, S. N. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1344191 · Cited by 420
Monte-Moreno, E. (2011) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2011.05.001 · Cited by 311
Noninvasive Glucose Monitoring: Comprehensive Clinical Results
Tamada, J. A., Garg, S., Jovanovic, L., Pitzer, K. R., Fermi, S., Potts, R. O., & and the Cygnus Research Team (1999) · JAMA · doi:10.1001/jama.282.19.1839 · Cited by 282
Couceiro, R., Carvalho, P., Paiva, R. P., Henriques, J., & Muehlsteff, J. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346497 · Cited by 33
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Chu, J., Yang, W.-T., Lu, W.-R., Chang, Y.-T., Hsieh, T.-H., & Yang, F.-L. (2021) · Sensors · doi:10.3390/s21237815 · Cited by 34
Bogue-Jimenez, B., Huang, X., Powell, D., & Doblas, A. (2022) · Sensors · doi:10.3390/s22093534 · Cited by 24
“…features because they have been shown to perform well in predicting BGLs or have a moderate correlation with blood sugar, and their respective sensors can be implemented in a smartwatch-like wearable device [16,17], enabling continuous measurements during the day and a rapid commercial adoption.”
BackgroundMethodResultInfluentialIn-Vivo Estimation of Glucose Level Using PPG Signal
Gupta, S. S., Hossain, S., Haque, C. A., & Kim, K.-D. (2020) · 2020 International Conference on Information and Communication Technology Convergence (ICTC) · doi:10.1109/ictc49870.2020.9289629 · Cited by 12
“In [11], authors have used multiple linear regression (MLR) and artificial neural network (ANN) techniques to predict the glucose concentration of the blood with galvanic skin response alongside PPG.”
Method
Metadata
- Authors
- Yadav, J., Rani, A., Singh, V., & Mohan Murari, B.
- Venue
- Journal of Medical Devices
- Publisher
- ASME International
- Published
- 2017-06-27
- Volume
- 11
- Issue
- 3
- ISSN
- 1932-6181 (ISSN-L)
- 1932-619X
- OpenAlex
- W2609703666
- Cited by
- 38
- References
- 5
- FWCI
- 1.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.