Experimental and theoretical investigation of chain length and surface coverage on fouling of surface grafted polypeptoids
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Numerous strategies exist to prevent biological fouling of surfaces in physiological environments; the authors’ strategy focuses on the modification of surfaces with poly-N-substituted glycine oligomers (polypeptoids). The authors previously reported the synthesis and characterization of three novel polypeptoid polymers that can be used to modify titanium oxide surfaces, rendering the surfaces resistant to adsorption of proteins, to adhesion of mammalian and bacterial cells, and to degradation by common protease enzymes. In this study, they investigated the effect of polypeptoid chain length on the antifouling properties of the modified surfaces. For these experiments, they used poly(N-methoxyethyl) glycines with lengths between 10 and 50 repeat units and determined the influence of chain length on coating thickness and density as well as resistance to protein adsorption and cellular adhesion. Short-term protein resistance remained low for all polymers, as measured by optical waveguide light mode spectroscopy, while fibroblast adhesion after several weeks indicated reduced fouling resistance for the polypeptoid-modified surfaces with the shortest chain length polymer. Experimental observations were compared to predictions obtained from a molecular theory of polymer and protein adsorption. Good agreement was found between experiment and theory for the chain length dependence of peptoid grafting density and for protein adsorption as a function of peptoid grafting density. The theoretical predictions provide specific guidelines for the surface coverage for each molecular weight for optimal antifouling. The predictions show the relationship between polymer layer structure and fouling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543
Holland, N. B., Qiu, Y., Ruegsegger, M., & Marchant, R. E. (1998) · Nature · doi:10.1038/33894 · Cited by 308
Cited by
Mussel-Inspired Adhesives and Coatings
Lee, B. P., Messersmith, P. B., Israelachvili, J. N., & Waite, J. H. (2011) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-062910-100429 · Cited by 1,668
Self-citationOn the biodegradability of polyethylene glycol, polypeptoids and poly(2-oxazoline)s
Ulbricht, J., Jordan, R., & Luxenhofer, R. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.02.029 · Cited by 348
Surface chemistry to minimize fouling from blood-based fluids
Blaszykowski, C., Sheikh, S., & Thompson, M. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35170f · Cited by 271
Peptoids and Polypeptoids at the Frontier of Supra- and Macromolecular Engineering
Gangloff, N., Ulbricht, J., Lorson, T., Schlaad, H., & Luxenhofer, R. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00201 · Cited by 265
Polyoxazolines for Nonfouling Surface Coatings — A Direct Comparison to the Gold Standard PEG
Konradi, R., Acikgoz, C., & Textor, M. (2012) · Macromolecular Rapid Communications · doi:10.1002/marc.201200422 · Cited by 264
Metadata
- Authors
- Statz, A. R., Kuang, J., Ren, C., Barron, A. E., Szleifer, I., & Messersmith, P. B.
- Venue
- Biointerphases
- Publisher
- American Vacuum Society
- Published
- 2009-05-21
- Volume
- 4
- Issue
- 2
- Pages
- FA22-FA32
- ISSN
- 1559-4106 (ISSN-L)
- 1934-8630
- OpenAlex
- W2016689029
- Cited by
- 50
- References
- 2
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental and theoretical investigation of chain length and surface coverage on fouling of surface grafted polypeptoids. https://app.cochat.ai/papers/10.1116/1.3115103
- The paper
- Statz, A. R., Kuang, J., Ren, C., Barron, A. E., Szleifer, I., & Messersmith, P. B. (2009). Experimental and theoretical investigation of chain length and surface coverage on fouling of surface grafted polypeptoids. Biointerphases. https://doi.org/10.1116/1.3115103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.