Cited by 15Advancements in Photolithography TechniquesAdvanced X-ray Imaging TechniquesX-ray Spectroscopy and Fluorescence Analysis

A step-and-repeat x-ray exposure system for 0.5 μm pattern replication

Hayasaka, T., Ishihara, S., Kinoshita, H., Takeuchi, N.·1985·Journal of Vacuum Science & Technology B: Microelectronics Processing and Phenomena

Abstract

A new step-and-repeat x-ray exposure system has been developed to establish practical submicron x-ray lithography. Penumbra and run-out error have been determined on the basis of resolution consideration and alignment accuracy analysis. The fundamental system parameters have been derived for constructing an efficient and accurate exposure system. To realize such a system, certain new technologies have been developed. (1) A high power Si–Kα x-ray source brings a large x-ray flux onto the wafer through a silicon nitride mask membrane. (2) The optical mark and gap detection method is connected to a precise alignment mechanism placed on an x–y table designed for wafer stepping. (3) This construction ensures atmospheric environment exposure. (4) The exposure system operation is fully automatic thanks to microprocessors. A 0.5 μm pattern has been accurately replicated, and a ±0.15 μm alignment accuracy has been achieved using this exposure system.

Integrity signals

Registry

Crossref · 10.1116/1.582942

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Cited by

Sorted by citations

Authors
Hayasaka, T., Ishihara, S., Kinoshita, H., & Takeuchi, N.
Affiliations
NTT (Japan) (JP)
Venue
Journal of Vacuum Science & Technology B: Microelectronics Processing and Phenomena
Published
1985-11-01
Volume
3
Issue
6
Pages
1581-1586
ISSN
  • 0734-211X (ISSN-L)
  • 2327-9877
OpenAlex
W2043991015
Cited by
15
References
0
Citations by year
2025: 1 · 2024: 1 · 2023: 1 · 2012: 1
FWCI
1.08
Type
journal article
Language
en
Open access
closed
Locations
Journal of Vacuum Science & Technology B Microelectronics Processing and Phenomena (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Photolithography Techniques
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
  • Physical Sciences › Physics and Astronomy › Radiation › X-ray Spectroscopy and Fluorescence Analysis
Keywords
X-ray lithography, penumbra, alignment accuracy, atmospheric exposure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review