The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Selective imaging of surface fluorescence with very high aperture microscope objectives
Open accessAbstract
Three approaches to selective surface fluorescence detection are described. All three of them depend on the use of extremely high numerical aperture (NA) objectives now commercially available (1.45 NA from Zeiss and Olympus and 1.65 NA from Olympus). The first two approaches are elaborations of "prismless" total internal reflection fluorescence (TIRF), one approach with a laser illumination and the second with arc lamp illumination. The new higher NA objectives are much more suitable for TIRF work on biological cells in culture than are 1.4 NA objectives previously described for prismless TIRF. The third approach is not TIRF at all. It uses the high aperture objective to selectively gather the emission of fluorophores located close enough to the substrate for their near-field energy to be captured by the substrate. Schematic diagrams, experimental demonstrations, and practical suggestions for all these techniques are provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct observation of single kinesin molecules moving along microtubules
Vale, R. D., Funatsu, T., Pierce, D. W., Romberg, L., Harada, Y., & Yanagida, T. (1996) · Nature · doi:10.1038/380451a0 · Cited by 711
Cited by
Total Internal Reflection Fluorescence Microscopy in Cell Biology
Axelrod, D. (2001) · Traffic · doi:10.1034/j.1600-0854.2001.21104.x · Cited by 959
Self-citationDynamics of insulin secretion and the clinical implications for obesity and diabetes
Seino, S., Shibasaki, T., & Minami, K. (2011) · Journal of Clinical Investigation · doi:10.1172/jci45680 · Cited by 364
Taraska, J. W., Perrais, D., Ohara-Imaizumi, M., Nagamatsu, S., & Almers, W. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0337526100 · Cited by 361
A real-time view of life within 100 nm of the plasma membrane
Steyer, J. A., & Almers, W. (2001) · Nature Reviews Molecular Cell Biology · doi:10.1038/35067069 · Cited by 349
Pancreatic β-Cells Secrete Insulin in Fast- and Slow-Release Forms
Michael, D. J., Ritzel, R. A., Haataja, L., & Chow, R. H. (2006) · Diabetes · doi:10.2337/diabetes.55.03.06.db05-1054 · Cited by 98
Human Insulin Vesicle Dynamics During Pulsatile Secretion
Michael, D. J., Xiong, W., Geng, X., Drain, P., & Chow, R. H. (2007) · Diabetes · doi:10.2337/db06-0367 · Cited by 69
Fluorescent Cargo Proteins in Pancreatic β-Cells: Design Determines Secretion Kinetics at Exocytosis
Michael, D. J., Geng, X., Cawley, N. X., Loh, Y. P., Rhodes, C. J., Drain, P., & Chow, R. H. (2004) · Biophysical Journal · doi:10.1529/biophysj.104.052175 · Cited by 66
Khiroug, S. S., Pryazhnikov, E., Coleman, S. K., Jeromin, A., Keinänen, K., & Khiroug, L. (2009) · BMC Neuroscience · doi:10.1186/1471-2202-10-141 · Cited by 19
Metadata
- Authors
- Axelrod, D.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2001
- Volume
- 6
- Issue
- 1
- Pages
- 6
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2065113965
- Cited by
- 158
- References
- 1
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.