The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Imaging caries lesions and lesion progression with polarization sensitive optical coherence tomography
Open accessAbstract
New diagnostic tools are needed for the characterization of dental caries in the early stages of development. If carious lesions are detected early enough, they can be arrested without the need for surgical intervention. The objective of this study was to demonstrate that polarization sensitive optical coherence tomography (PS-OCT) can be used for the imaging of early caries lesions and for the monitoring of lesion progression over time. High-resolution polarization resolved images were acquired of natural caries lesions and simulated caries lesions of varying severity created over time periods of 1 to 14 days. Linearly polarized light was incident on the tooth samples and the reflected intensity in both orthogonal polarizations was measured. PS-OCT was invaluable for removing the confounding influence of surface reflections and native birefringence necessary for the enhanced resolution of the surface structure of caries lesions. This study demonstrated that PS-OCT is well suited for the imaging of interproximal and occlusal caries, early root caries, and for imaging decay under composite fillings. Longitudinal measurements of the reflected light intensity in the orthogonal polarization state from the area of simulated caries lesions linearly correlated with the square root of time of demineralization indicating that PS-OCT is well suited for monitoring changes in enamel mineralization over time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Prevention and reversal of dental caries: role of low level fluoride
Featherstone, J. D. B. (1999) · Community Dentistry and Oral Epidemiology · doi:10.1111/j.1600-0528.1999.tb01989.x · Cited by 989
Self-citationOptical coherence-domain reflectometry: a new optical evaluation technique
Youngquist, R. C., Carr, S., & Davies, D. E. N. (1987) · Optics Letters · doi:10.1364/ol.12.000158 · Cited by 597
Featherstone, J. D. B., ten Cate, J. M., Shariati, M., & Arends, J. (1983) · Caries Research · doi:10.1159/000260692 · Cited by 520
Self-citationLussi, A., Imwinkelried, S., Pitts, N. B., Longbottom, C., & Reich, E. (1999) · Caries Research · doi:10.1159/000016527 · Cited by 466
Kaste, L. M., Selwitz, R. H., Oldakowski, R. J., Brunelle, J. A., Winn, D. M., & Brown, L. J. (1996) · Journal of Dental Research · doi:10.1177/002203459607502s03 · Cited by 465
Nature of light scattering in dental enamel and dentin at visible and near-infrared wavelengths
Fried, D., Glena, R. E., Featherstone, J. D. B., & Seka, W. (1995) · Applied Optics · doi:10.1364/ao.34.001278 · Cited by 361
Self-citationFeatherstone, J. D. B., Glena, R., Shariati, M., & Shields, C. P. (1990) · Journal of Dental Research · doi:10.1177/00220345900690s121 · Cited by 240
Self-citationPolarization–Sensitive Optical Coherence Tomography of Dental Structures
Baumgartner, A., Dichtl, S., Hitzenberger, C. K., Sattmann, H., Robl, B., Moritz, A., Fercher, A. F., & Sperr, W. (2000) · Caries Research · doi:10.1159/000016571 · Cited by 235
Imaging of hard- and soft-tissue structure in the oral cavity by optical coherence tomography
Colston, B. W., Everett, M. J., Da Silva, L. B., Otis, L. L., Stroeve, P., & Nathel, H. (1998) · Applied Optics · doi:10.1364/ao.37.003582 · Cited by 228
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Miniature endoscopic optical coherence tomography for calculus detection
Kao, M.-C., Lin, C.-L., Kung, C.-Y., Huang, Y.-F., & Kuo, W.-C. (2015) · Applied Optics · doi:10.1364/ao.54.007419 · Cited by 19
Metadata
- Authors
- Fried, D., Xie, J., Shafi, S., Featherstone, J. D. B., Breunig, T. M., & Le, C.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2002
- Volume
- 7
- Issue
- 4
- Pages
- 618
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2012500966
- Cited by
- 331
- References
- 18
- FWCI
- 6.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging caries lesions and lesion progression with polarization sensitive optical coherence tomography. https://app.cochat.ai/papers/10.1117/1.1509752
- The paper
- Fried, D., Xie, J., Shafi, S., Featherstone, J. D. B., Breunig, T. M., & Le, C. (2002). Imaging caries lesions and lesion progression with polarization sensitive optical coherence tomography. Journal of Biomedical Optics. https://doi.org/10.1117/1.1509752
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.