Three-dimensional terahertz pulse imaging of dental tissue
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
There are unresolved clinical problems that require the provision of accurate 3-D images of tissue structures such as teeth. In particular, measurements of dental enamel thickness are necessary to quantify problems associated with enamel erosion, yet currently there is no nondestructive method to obtain this information. We present a method that relies on the use of pulsed terahertz radiation to gain 3-D information from dental tissues. We discuss results from 14 samples and demonstrate that we can reliably and accurately quantify enamel thickness. We show that in a series of 22 surfaces, we can image pertinent subsurface features 91% of the time. Example images are shown where structures in teeth at depth are rendered accurate to within 10 microm. We discuss issues that arise using this imaging method and propose ways in which it could be used in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mittleman, D. M., Hunsche, S., Boivin, L., & Nuss, M. C. (1997) · Optics Letters · doi:10.1364/ol.22.000904 · Cited by 519
Cited by
Metal wires for terahertz wave guiding
Wang, K., & Mittleman, D. M. (2004) · Nature · doi:10.1038/nature03040 · Cited by 1,075
Imaging with terahertz radiation
Chan, W. L., Deibel, J., & Mittleman, D. M. (2007) · Reports on Progress in Physics · doi:10.1088/0034-4885/70/8/r02 · Cited by 965
Biomedical applications of terahertz technology
Pickwell, E., & Wallace, V. P. (2006) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/39/17/r01 · Cited by 925
Self-citationReview of terahertz photoconductive antenna technology
Burford, N. M., & El-Shenawee, M. O. (2017) · Optical Engineering · doi:10.1117/1.oe.56.1.010901 · Cited by 453
Progress in terahertz nondestructive testing: A review
Zhong, S. (2019) · Frontiers of Mechanical Engineering · doi:10.1007/s11465-018-0495-9 · Cited by 395
THz Medical Imaging: in vivo Hydration Sensing
Taylor, Z. D., Singh, R. S., Bennett, D. B., Tewari, P., Kealey, C. P., Bajwa, N., Culjat, M. O., Stojadinovic, A., Lee, H., Hubschman, J.-P., et al. (2011) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2011.2159551 · Cited by 362
Nondestructive analysis of tablet coating thicknesses using terahertz pulsed imaging
Fitzgerald, A. J., Cole, B. E., & Taday, P. F. (2005) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.20225 · Cited by 289
Self-citationApplications of terahertz spectroscopy to pharmaceutical sciences
Taday, P. F. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2003.1321 · Cited by 239
“Other possible medical applications include THz imaging of teeth (Crawley et al. 2003).”
BackgroundHidden object detection: security applications of terahertz technology
Tribe, W. R., Newnham, D. A., Taday, P. F., & Kemp, M. C. (2004) · SPIE Proceedings · doi:10.1117/12.543049 · Cited by 189
“Another possible medical application is the terahertz imaging of teeth.(8)”
BackgroundTerahertz Dielectric Sensitivity to Biomolecular Structure and Function
Markelz, A. G. (2008) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2007.913424 · Cited by 178
“There was some success in finding tooth decay [97] and basal cell carcinoma [98], [99].”
BackgroundOptical properties of tissue measured using terahertz pulsed imaging
Berry, E., Fitzgerald, A. J., Zinov'ev, N. N., Walker, G. C., Homer-Vanniasinkam, S., Sudworth, C. D., Miles, R. E., Chamberlain, J. M., & Smith, M. A. (2003) · SPIE Proceedings · doi:10.1117/12.479993 · Cited by 92
Metadata
- Authors
- Crawley, D., Longbottom, C., Wallace, V. P., Cole, B., Arnone, D., & Pepper, M.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2003
- Volume
- 8
- Issue
- 2
- Pages
- 303
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2043191335
- Cited by
- 153
- References
- 1
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.