Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Muscle blood flow (MBF) and muscle oxygen saturation (SmO2) were measured at eight locations (four proximal, four distal) over a 4×8 cm2 area of the vastus lateralis at rest and immediately after isometric, maximal quadriceps contraction using multichannel, frequency-domain, near-infrared spectroscopy. A venous occlusion was applied 20 s before the end of the exercise, so that the venous-occlusion-induced increase in total hemoglobin was recorded without any delay after the end of the exercise. Therefore, we were able to investigate the relationship between the exercise-induced changes in vastus lateralis MBF and SmO2. After exercise, MBF increased significantly at each measured location. Comparing the MBF values measured at the end of exercise in the proximal and distal regions, we observed that only one proximal region had a significantly higher MBF than the corresponding distal one. The maximum desaturation measured during exercise was positively correlated with the postexercise to pre-exercise MBF ratio in both the proximal (P = 0.016) and distal (P = 0.0065) regions. These data confirm that frequency-domain tissue oximeters are noninvasive, powerful tools to investigate the spatial and temporal features of muscle blood flow and oxygenation, with potential applications in areas of pathophysiology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Since myoglobin cannot be distinguished from hemoglobin due to the spectral overlap (Quaresima et al. 2004), its contribution is combined into the calculated oxy‐ and deoxy‐hemoglobin concentrations.”
From Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle (2018) · cites this paper as Quaresima et al. 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
Wittenberg, J. B., & Wittenberg, B. A. (2003) · Journal of Experimental Biology · doi:10.1242/jeb.00243 · Cited by 550
Van Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Self-citationIntramuscular fluid pressure during isometric contraction of human skeletal muscle
Sejersted, O. M., Hargens, A. R., Kardel, K. R., Blom, P., Jensen, O., & Hermansen, L. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.2.287 · Cited by 355
González-Alonso, J., Olsen, D. B., & Saltin, B. (2002) · Circulation Research · doi:10.1161/01.res.0000044939.73286.e2 · Cited by 331
Near‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
Noninvasive measurement of forearm blood flow and oxygen consumption by near-infrared spectroscopy
De Blasi, R. A., Ferrari, M., Natali, A., Conti, G., Mega, A., & Gasparetto, A. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.3.1388 · Cited by 292
Self-citationFantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
Self-citation
Research works printed but not linked: 1
- van Beekvelt, 2001, J. Appl. Physiol., 90, 511, 10.1152/jappl.2001.90.2.511 · DOI · Paper page
Cited by
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Self-citationHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationChoe, R., Corlu, A., Lee, K., Durduran, T., Konecky, S. D., Grosicka‐Koptyra, M., Arridge, S. R., Czerniecki, B. J., Fraker, D. L., DeMichele, A., et al. (2005) · Medical Physics · doi:10.1118/1.1869612 · Cited by 295
Yu, G., Durduran, T., Lech, G., Zhou, C., Chance, B., Mohler, E. R., & Yodh, A. G. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1884603 · Cited by 230
Yu, G., Floyd, T. F., Durduran, T., Zhou, C., Wang, J., Detre, J. A., & Yodh, A. G. (2007) · Optics Express · doi:10.1364/oe.15.001064 · Cited by 223
Myers, D. E., Anderson, L. D., Seifert, R. P., Ortner, J. P., Cooper, C. E., Beilman, G. J., & Mowlem, J. D. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1925250 · Cited by 187
Hamaoka, T., McCully, K. K., Niwayama, M., & Chance, B. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0298 · Cited by 186
Lucero, A. A., Addae, G., Lawrence, W., Neway, B., Credeur, D. P., Faulkner, J., ROWLANDS, D. S., & Stoner, L. R. (2017) · Experimental Physiology · doi:10.1113/ep086537 · Cited by 117
“In addition, mBF can vary throughout a single muscle (Quaresima et al. 2004) and is tightly matched to metabolic demand (Joyner & Casey, 2015).”
BackgroundMethodInfluentialHamaoka, T., & McCully, K. K. (2019) · The Journal of Physiological Sciences · doi:10.1007/s12576-019-00697-2 · Cited by 92
Farzam, P., Starkweather, Z., & Franceschini, M. A. (2018) · Physiological Reports · doi:10.14814/phy2.13664 · Cited by 107
Self-citationShang, Y., Li, T., & Yu, G. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa60b7 · Cited by 95
The Effects of Wearing Undersized Lower-Body Compression Garments on Endurance Running Performance
Dascombe, B. J., Hoare, T. K., Sear, J. A., Reaburn, P. R. J., & Scanlan, A. T. (2011) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.6.2.160 · Cited by 92
Diffuse optical tomography and spectroscopy of breast cancer and fetal brain
Choe, R. (2005) · Medical Physics · doi:10.1118/1.2047847 · Cited by 74
Asymmetry of quadriceps muscle oxygenation during elite short-track speed skating
HESFORD, C. M., LAING, S. J., CARDINALE, M., & COOPER, C. E. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31822f8942 · Cited by 63
“Recent studies have reported regional heterogeneity in vastus lateralis oxygenation as measured by NIRS (17,24).”
Muscle oxygenation after downhill walking‐induced muscle damage
Ahmadi, S., Sinclair, P. J., & Davis, G. M. (2007) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2007.00777.x · Cited by 67
“The NIRS system, which has been previously described (Quaresima et al., 2004), com-”
MethodBinzoni, T., Cooper, C. E., Wittekind, A., Beneke, R., Elwell, C. E., Ville, D. V. D., & Leung, T. S. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/014 · Cited by 47
“The previous paragraphs indirectly highlight the differences between classical NIRSbased tissue oxygen saturation measurements (McCully and Hamaoka 2000, Rolfe 2000, Boushel et al 2001, Quaresima et al 2003, Bhambhani 2004, Ferrari et al 2004, Hamaoka et al 2007, Wolf et al 2007), that include myoglobin and haemoglobi…”
BackgroundInfluentialLocal increase in trapezius muscle oxygenation during and after acupuncture
Ohkubo, M., Hamaoka, T., Niwayama, M., Murase, N., Osada, T., Kime, R., Kurosawa, Y., Sakamoto, A., & Katsumura, T. (2009) · Dynamic Medicine · doi:10.1186/1476-5918-8-2 · Cited by 37
“lateral or proximal to the stimulation point, multichannel NIRS should be used in future studies [22].”
MethodPulsatile and steady-state hemodynamics of the human patella bone by diffuse optical spectroscopy
Farzam, P., Zirak, P., Binzoni, T., & Durduran, T. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/839 · Cited by 28
Ohmae, E., Nishio, S., Oda, M., Suzuki, H., Suzuki, T., Ohashi, K., Koga, S., Yamashita, Y., & Watanabe, H. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.6.067005 · Cited by 33
“6(b)] was similar to that obtained by SGP_FBF.”
MethodInfluentialChanges in optical properties of tissue during acute wound healing in an animal model
Papazoglou, E. S., Weingarten, M. S., Zubkov, L. A., Neidrauer, M. T., Zhu, L., Tyagi, S., & Pourrezaei, K. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2960952 · Cited by 29
Pichler, G., Grossauer, K., Peichl, E., Gaster, A., Berghold, A., Schwantzer, G., Zotter, H., Müller, W. D., & Urlesberger, B. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3076193 · Cited by 25
“adults, peripheral muscle tissue shows a spatial distribution pattern within different regions of a muscle.(8) The calf and”
BackgroundZhang, Z., Wang, B., Gong, H., Xu, G., Nioka, S., & Chance, B. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3309741 · Cited by 34
Hu, G., Zhang, Q., Ivković, V., & Strangman, G. E. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091314 · Cited by 25
Crenshaw, A. G., Bronee, L., Krag, I. R., & Jensen, B. R. (2010) · Journal of Sports Sciences · doi:10.1080/02640414.2010.489195 · Cited by 22
Ferrante, S., Contini, D., Spinelli, L., Pedrocchi, A., Torricelli, A. M., Molteni, F., Ferrigno, G., & Cubeddu, R. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3183802 · Cited by 21
Toi, V. V., Hammer, P. E., Hoimes, M. L., Nadgir, S., & Fantini, S. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.890123 · Cited by 19
“Fig. 7(c) shows the values of blood flow (BF) computed from the experimental data using the equation , where is the concentration of hemoglobin in blood for which we have assumed a typical value of 2.3 mM, and we have used the maximum time derivative of THC during the first 10 s of occlusion [ 25 ].”
MethodSelf-citationSmit, C. A. J., Berenpas, F., de Groot, S., Stolwijk-Swüste, J. M., & Janssen, T. W. J. (2020) · Spinal Cord Series and Cases · doi:10.1038/s41394-019-0254-0 · Cited by 11
Intelligent Systems for Muscle Tracking: A Review on Sensor‐Algorithm Synergy
Putcha, A., Nguyen, T., Smith, R., Choffin, R., & Bai, W. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200351 · Cited by 10
Fernandez, C. M., Blaney, G. P., Frias, J., Tavakoli, F., Sassaroli, A., & Fantini, S. (2023) · Journal of Biomedical Optics · doi:10.1117/1.jbo.28.12.125004 · Cited by 9
“9,34,37 The datasets for this study resulted in similar Δ μ a; Exp for the two SDs at the same distance but on opposite sides on the probe [Fig.”
BackgroundMethodSelf-citationChen, D. K., Erb, M. K., Tong, Y., Yu, Y., Sassaroli, A., Bergethon, P. R., & Fantini, S. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000923 · Cited by 8
Self-citationCoelho, C. C., Aquino, E. D. S., Diniz, A. L. X., Santos, M. D. S., de Oliveira, L. C., Poeiras, P. T. C., & Pereira, D. A. G. (2020) · Experimental Physiology · doi:10.1113/ep088764 · Cited by 7
“Changes in spirometry, such as the reduction in the FEV1 (% predicted), are known factors influencing exercise intolerance (Quaresima et al., 2004) and the distance walked in the MST as stated in the classification of lung disease severity (Vendrusculo et al., 2019).”
Hemodynamics Study Based on Near-Infrared Optical Assessment
Sun, C., & Chuang, C. (2012) · InTech eBooks · doi:10.5772/38229 · Cited by 10
A novel noninvasive all optical technique to monitor physiology of an exercising muscle
Saxena, V., Marcu, L., & Karunasiri, G. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/21/021 · Cited by 5
“Diffuse optical near-infrared spectroscopy is sensitive to smaller vessels like arterioles, capillaries and venules (Quaresima et al 2004) and can provide dynamic information about the changes in total hemoglobin and tissue blood oxygen saturation due to an increase in blood flow during exercise…”
BackgroundEffects of acute hypoxia on the oxygen uptake kinetics of older adults during cycling exercise
Zerbini, L., Brighenti, A., Pellegrini, B., Bortolan, L., Antonetti, T., & Schena, F. F. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-048 · Cited by 5
Chambers, A. J., Haney, J. M., Huppert, T. J., & Redfern, M. S. (2019) · PubMed Central · Cited by 5
Tseng, S.-H., Liang, B. T., Wang, W., Tsai, B.-X., & Hu, P. (2021) · Biomedical Optics Express · doi:10.1364/boe.428207 · Cited by 2
Hybrid diffuse optics for monitoring of tissue hemodynamics with applications in oncology
Farzam, P. (2014) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-95505 · Cited by 3
“The measured oxygen saturation in baseline is 65% which is in the range of healthy human tissue and bones [119, 153, 306].”
BackgroundIzumi, K., Katayama, K., Kano, Y., Tanaka, N., & Akima, H. (2026) · Physiological Reports · doi:10.14814/phy2.70783 · Cited by 1
Haney, J. M. (2014) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 2
Hemodynamic Changes in the Dominant and Non-Dominant Arms after a Tennis Training Session
Ho, K.-L., Chen, S.-M., Korivi, M., Chuang, C.-J., Kuo, C.-H., & Yu, S.-H. (2011) · Adaptive Medicine · doi:10.4247/am.2011.aba016
Ichimura, S., Katsumura, T., Moriguchi, T., Yamada, Y., Nakagawa, N., Niwayama, M., Yamamoto, K., & Hamaoka, T. (2012) · The Journal of Japanese College of Angiology · doi:10.7133/jca.52.115
Caractérisation des milieux mous par optoélastographie transitoire
Daoudi, K. (2009) · HAL
Lucero, A. A., Gram, M., Ramakers, I., Ryan, T., Enriquez, O., Faulkner, J., Stoner, L. R., & ROWLANDS, D. S. (2026) · European Journal of Applied Physiology · doi:10.1007/s00421-026-06300-y
“However, immediate post-exercise mBF increases in pro - portion to exercise intensity (Kagaya and Homma 1997) and reflects the mBF response to exercise (Quaresima et al. 2004 ).”
Metadata
- Authors
- Quaresima, V., Ferrari, M., Franceschini, M. A., Hoimes, M. L., & Fantini, S.
- Affiliations
- University of L'Aquila (IT)
- Tufts University (US)
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2004-03-01
- Volume
- 9
- Issue
- 02
- Pages
- 413-420
- ISSN
- 1083-3668 (ISSN-L)
- 1560-2281
- OpenAlex
- W2102663326
- Semantic Scholar
- f531f8015e6e330c6d311716a9a7b49d50ba2072
- Cited by
- 45
- References
- 38
- Citations by year
- 2026: 2 · 2023: 2 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 2 · 2016: 1 · 2014: 3 · 2013: 1 · 2012: 3
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Biomedical Optics (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- INFM-OAR (INFN Catania) (submittedVersion, other-oa)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Mental Health (R01-MH62854, R01MH062854)
- National Institute of Biomedical Imaging and Bioengineering (R01EB001954)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD042908, R01 HD42908)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Keywords
- vastus lateralis, muscle blood flow, muscle oxygen saturation, venous occlusion, spatial distribution, muscle oxygenation, exercise-induced desaturation, frequency-domain near-infrared spectroscopy, tissue oximetry
- MeSH terms
- Adult, Hip, Humans, Isometric Contraction, Oxyhemoglobins, Regional Blood Flow, Thigh, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.