Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Muscle blood flow (MBF) and muscle oxygen saturation (SmO2) were measured at eight locations (four proximal, four distal) over a 4×8 cm2 area of the vastus lateralis at rest and immediately after isometric, maximal quadriceps contraction using multichannel, frequency-domain, near-infrared spectroscopy. A venous occlusion was applied 20 s before the end of the exercise, so that the venous-occlusion-induced increase in total hemoglobin was recorded without any delay after the end of the exercise. Therefore, we were able to investigate the relationship between the exercise-induced changes in vastus lateralis MBF and SmO2. After exercise, MBF increased significantly at each measured location. Comparing the MBF values measured at the end of exercise in the proximal and distal regions, we observed that only one proximal region had a significantly higher MBF than the corresponding distal one. The maximum desaturation measured during exercise was positively correlated with the postexercise to pre-exercise MBF ratio in both the proximal (P = 0.016) and distal (P = 0.0065) regions. These data confirm that frequency-domain tissue oximeters are noninvasive, powerful tools to investigate the spatial and temporal features of muscle blood flow and oxygenation, with potential applications in areas of pathophysiology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Since myoglobin cannot be distinguished from hemoglobin due to the spectral overlap (Quaresima et al. 2004), its contribution is combined into the calculated oxy‐ and deoxy‐hemoglobin concentrations.”
From Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle (2018) · cites this paper as Quaresima et al. 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
Wittenberg, J. B., & Wittenberg, B. A. (2003) · Journal of Experimental Biology · doi:10.1242/jeb.00243 · Cited by 550
Van Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Self-citationIntramuscular fluid pressure during isometric contraction of human skeletal muscle
Sejersted, O. M., Hargens, A. R., Kardel, K. R., Blom, P., Jensen, O., & Hermansen, L. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.2.287 · Cited by 355
González-Alonso, J., Olsen, D. B., & Saltin, B. (2002) · Circulation Research · doi:10.1161/01.res.0000044939.73286.e2 · Cited by 331
Near‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
Noninvasive measurement of forearm blood flow and oxygen consumption by near-infrared spectroscopy
De Blasi, R. A., Ferrari, M., Natali, A., Conti, G., Mega, A., & Gasparetto, A. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.3.1388 · Cited by 292
Self-citationFantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
Self-citation
Research works printed but not linked: 1
- van Beekvelt, 2001, J. Appl. Physiol., 90, 511, 10.1152/jappl.2001.90.2.511 · DOI · Paper page
Cited by
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Self-citationHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationChoe, R., Corlu, A., Lee, K., Durduran, T., Konecky, S. D., Grosicka‐Koptyra, M., Arridge, S. R., Czerniecki, B. J., Fraker, D. L., DeMichele, A., et al. (2005) · Medical Physics · doi:10.1118/1.1869612 · Cited by 295
Yu, G., Durduran, T., Lech, G., Zhou, C., Chance, B., Mohler, E. R., & Yodh, A. G. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1884603 · Cited by 230
Yu, G., Floyd, T. F., Durduran, T., Zhou, C., Wang, J., Detre, J. A., & Yodh, A. G. (2007) · Optics Express · doi:10.1364/oe.15.001064 · Cited by 223
Metadata
- Authors
- Quaresima, V., Ferrari, M., Franceschini, M. A., Hoimes, M. L., & Fantini, S.
- Affiliations
- University of L'Aquila (IT)
- Tufts University (US)
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2004-03-01
- Volume
- 9
- Issue
- 02
- Pages
- 413-420
- ISSN
- 1083-3668 (ISSN-L)
- 1560-2281
- OpenAlex
- W2102663326
- Semantic Scholar
- f531f8015e6e330c6d311716a9a7b49d50ba2072
- Cited by
- 45
- References
- 38
- Citations by year
- 2026: 2 · 2023: 2 · 2021: 1 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 2 · 2016: 1 · 2014: 3 · 2013: 1 · 2012: 3
- FWCI
- 2.79
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Biomedical Optics (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- INFM-OAR (INFN Catania) (submittedVersion, other-oa)
- Funders
- National Science Foundation
- National Institutes of Health
- National Institute of Mental Health (R01-MH62854, R01MH062854)
- National Institute of Biomedical Imaging and Bioengineering (R01EB001954)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD042908, R01 HD42908)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Keywords
- vastus lateralis, muscle blood flow, muscle oxygen saturation, venous occlusion, spatial distribution, muscle oxygenation, exercise-induced desaturation, frequency-domain near-infrared spectroscopy, tissue oximetry
- MeSH terms
- Adult, Hip, Humans, Isometric Contraction, Oxyhemoglobins, Regional Blood Flow, Thigh, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.