CoChat

Precision of measurement of cerebral tissue oxygenation index using near-infrared spectroscopy in preterm neonates

Open access
Sorensen, Line C., Greisen, Gorm · 2006 · Journal of Biomedical Optics
Cited by 112

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The use of cerebral tissue oxygenation index (c-TOI) in a clinical setting is limited by doubts concerning the accuracy of the measurements. Since there is no gold standard, validation is difficult. Our modest aim was to quantify the precision of c-TOI doing repeated measurements by reapplying the optode several times presuming no regional differences in cerebral oxygenation. Thirty-seven premature infants were examined with several measurements of c-TOI using the NIRO 300 oximeter. Three to eight measurements were done on each infant over a period of 15 to 25 min. One-way analysis of variance was used to estimate within- and between-infant variation. The median gestational age was 27.6 weeks (23.9 to 33.0). Mean c-TOI (n = 253) was 74.6+/-8.5%. The within-infant variation was 5.2% when resiting the optode. For comparison, the between-infants variation was 6.9%, while the spontaneous 2-sec variation was 2.9%. The precision of a single measurement of c-TOI was not good. By measuring five times instead of one on each subject, the precision of the mean can be assumed to be comparable to pulse oximetry. This may be too cumbersome for clinical use, but may reduce sample size in research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.2357730

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 112

Metadata

Authors
Sorensen, L. C., & Greisen, G.
Venue
Journal of Biomedical Optics
Published
2006
Volume
11
Issue
5
Pages
054005
ISSN
1083-3668 (ISSN-L)
OpenAlex
W2080181287
Cited by
112
References
2
FWCI
4.03
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Precision of measurement of cerebral tissue oxygenation index using near-infrared spectroscopy in preterm neonates. https://app.cochat.ai/papers/10.1117/1.2357730
The paper
Sorensen, L. C., & Greisen, G. (2006). Precision of measurement of cerebral tissue oxygenation index using near-infrared spectroscopy in preterm neonates. Journal of Biomedical Optics. https://doi.org/10.1117/1.2357730

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.