Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 274

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Snapshot hyperspectral imaging in ophthalmology

Open access
Johnson, William R., Wilson, Daniel W., Fink, Wolfgang, Humayun, Mark, Bearman, Greg·2007·Journal of Biomedical Optics

Abstract

Retinal imaging spectroscopy can provide functional maps using chromophore spectra. For example, oxygen saturation maps show ischemic areas from diabetes and venous occlusions. Obtaining retinal spatial-spectral data has been difficult due to saccades and long data acquisition times (>5 s). We present a snapshot imaging spectrometer with far-reaching applicability that acquires a complete spatial-spectral image cube in approximately 3 ms from 450 to 700 nm with 50 bands, eliminating motion artifacts and pixel misregistration. Current retinal spectral imaging approaches are incapable of true snapshot operation over a wide spectral range with a large number of spectral bands. Coupled to a fundus camera, the instrument returns true color retinal images for comparison to standard fundus images and for image validation while the patient is still dilated. Oxygen saturation maps were obtained with a three-wavelength algorithm: for healthy subjects arteries were approximately 95% and veins 30 to 35% less. The instrument is now undergoing clinical trials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.2434950

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 274

Metadata

Authors
Johnson, W. R., Wilson, D. W., Fink, W., Humayun, M., & Bearman, G.
Venue
Journal of Biomedical Optics
Published
2007
Volume
12
Issue
1
Pages
014036
ISSN
1083-3668 (ISSN-L)
OpenAlex
W2137009054
Cited by
274
References
11
FWCI
7.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Snapshot hyperspectral imaging in ophthalmology. https://app.cochat.ai/papers/10.1117/1.2434950
The paper
Johnson, W. R., Wilson, D. W., Fink, W., Humayun, M., & Bearman, G. (2007). Snapshot hyperspectral imaging in ophthalmology. Journal of Biomedical Optics. https://doi.org/10.1117/1.2434950

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.