CoChat

First-in-human pilot study of a spatial frequency domain oxygenation imaging system

Open access
Gioux, Sylvain, Stockdale, Alan, Oketokoun, Rafiou, Ashitate, Yoshitomo, Durr, Nicholas J., Moffitt, Lorissa A., Frangioni, John V., Mazhar, Amaan, Tromberg, Bruce J., Durkin, Anthony J., Lee, Bernard T., Lin, Samuel J., Tobias, Adam M., Cuccia, David J., Kelly, Edward, Weinmann, Maxwell · 2011 · Journal of Biomedical Optics
Cited by 166

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Oxygenation measurements are widely used in patient care. However, most clinically available instruments currently consist of contact probes that only provide global monitoring of the patient (e.g., pulse oximetry probes) or local monitoring of small areas (e.g., spectroscopy-based probes). Visualization of oxygenation over large areas of tissue, without a priori knowledge of the location of defects, has the potential to improve patient management in many surgical and critical care applications. In this study, we present a clinically compatible multispectral spatial frequency domain imaging (SFDI) system optimized for surgical oxygenation imaging. This system was used to image tissue oxygenation over a large area (16×12 cm) and was validated during preclinical studies by comparing results obtained with an FDA-approved clinical oxygenation probe. Skin flap, bowel, and liver vascular occlusion experiments were performed on Yorkshire pigs and demonstrated that over the course of the experiment, relative changes in oxygen saturation measured using SFDI had an accuracy within 10% of those made using the FDA-approved device. Finally, the new SFDI system was translated to the clinic in a first-in-human pilot study that imaged skin flap oxygenation during reconstructive breast surgery. Overall, this study lays the foundation for clinical translation of endogenous contrast imaging using SFDI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.3614566

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 166

Metadata

Authors
Gioux, S., Stockdale, A., Oketokoun, R., Ashitate, Y., Durr, N. J., Moffitt, L. A., Frangioni, J. V., Mazhar, A., Tromberg, B. J., Durkin, A. J., Lee, B. T., Lin, S. J., Tobias, A. M., Cuccia, D. J., Kelly, E., & Weinmann, M.
Venue
Journal of Biomedical Optics
Published
2011-08-01
Volume
16
Issue
08
Pages
1
ISSN
1083-3668 (ISSN-L)
OpenAlex
W2047084786
Cited by
166
References
4
FWCI
5.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.