Spectral analysis of human saliva for detection of lung cancer using surface-enhanced Raman spectroscopy
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Surface-enhanced Raman spectroscopy (SERS) has been shown to be able to detect low-concentration biofluids. Saliva SERS readings of 21 lung cancer patients and 20 normal people were measured and differentiated. Most of the Raman peak intensities decrease for lung cancer patients compared with that of normal people. Those peaks were assigned to proteins and nucleic acids, which indicate a corresponding decrease of those substances in saliva. Principal component analysis (PCA) and linear discriminant analysis (LDA) were used to reduce and discriminate between the two groups of data, and the study resulted in accuracy, sensitivity, and specificity being 80%, 78%, and 83%, respectively. In conclusion, SERS of saliva showed the ability to predict lung cancer in our experiment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Bray, F., Center, M. M., Ferlay, J., Ward, E., & Forman, D. (2011) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20107 · Cited by 54,679
Global Cancer Statistics, 2002
Parkin, D. M., Bray, F., Ferlay, J., & Pisani, P. (2005) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.55.2.74 · Cited by 18,196 · cited 1×
“Lung cancer ranked first in terms of incidence and mortality, with a five-year survival rate of 15%.(1) The routine diagnosing process includes a series of examinations such as physical examination, imaging tests, and biopsies, which are time-consuming and invasive.”
BackgroundProbing Single Molecules and Single Nanoparticles by Surface-Enhanced Raman Scattering
Nie, S., & Emory, S. R. (1997) · Science · doi:10.1126/science.275.5303.1102 · Cited by 10,238
Reference database of Raman spectra of biological molecules
De Gelder, J., De Gussem, K., Vandenabeele, P., & Moens, L. (2007) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1734 · Cited by 1,425 · cited 1×
“For example, C − C stretch vibration has a Raman shift as 1084 cm−1 in lauric acid, but it moves to 1092 cm−1 in myristic acid, and 1099 cm−1 in palmitic acid.(24) Therefore, certain errors in the peak assignments based on the literature might exist due to totally different measuring conditions.”
BackgroundRaman spectroscopy for identification of epithelial cancers
Stone, N., Kendall, C., Smith, J., Crow, P., & Barr, H. (2004) · Faraday Discussions · doi:10.1039/b304992b · Cited by 768
Virkler, K., & Lednev, I. K. (2009) · Forensic Science International · doi:10.1016/j.forsciint.2009.02.013 · Cited by 714
Surface-enhanced Raman spectroscopy: substrate-related issues
Lin, X., Cui, Y., Xu, Y., Ren, B. W., & Tian, Z. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2761-5 · Cited by 678
Near infrared Raman spectra of human brain lipids
Krafft, C., Neudert, L., Simat, T., & Salzer, R. (2005) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2004.11.017 · Cited by 603
Salivary Proteomics for Oral Cancer Biomarker Discovery
Hu, S., Arellano, M., Boontheung, P., Wang, J., Zhou, H., Jiang, J., Elashoff, D., Wei, R., Loo, J. A., & Wong, D. T. (2008) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-5037 · Cited by 542 · cited 1×
“5-mL centrifuge tube and was centrifuged at 14,000 rpm for 10 min to remove the oral mucous epithelial cells and food debris.(8) The whole collection process was performed at a temperature of 4 °C.”
MethodSurface-Enhanced Raman Spectroscopy of DNA
Barhoumi, A., Zhang, D., Tam, F., & Halas, N. J. (2008) · Journal of the American Chemical Society · doi:10.1021/ja800023j · Cited by 523
Cited by
Review of Surface Enhanced Raman Scattering Applications in Forensic Science
Muehlethaler, C., Leona, M., & Lombardi, J. R. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04131 · Cited by 313
Salivary biomarkers in cancer detection
Wang, X., Kaczor-Urbanowicz, K. E., & Wong, D. T. W. (2017) · Medical Oncology · doi:10.1007/s12032-016-0863-4 · Cited by 225
“[26] introduced SERS to identify lung cancer biomarkers in saliva.”
BackgroundMethodInfluentialBonifacio, A., Cervo, S., & Sergo, V. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8697-z · Cited by 223
“In tears and saliva, on the basis of the few reports available [62, 63], the proteins do not seem to hinder aggregation in metal colloids used as SERS substrates.”
BackgroundFeng, S., Lin, D., Lin, J., Li, B., Huang, Z., Chen, G., Zhang, W., Wang, L., Pan, J., Chen, R., et al. (2013) · The Analyst · doi:10.1039/c3an36890d · Cited by 185
Dong, T., Matos Pires, N. M., Yang, Z., & Jiang, Z. (2023) · Advanced Science · doi:10.1002/advs.202205429 · Cited by 104
Metadata
- Authors
- Li, X.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2012-03-19
- Volume
- 17
- Issue
- 3
- Pages
- 037003
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2038242568
- Cited by
- 161
- References
- 29
- FWCI
- 4.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.