In vivo preclinical photoacoustic imaging of tumor vasculature development and therapy
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
The use of a novel all-optical photoacoustic scanner for imaging the development of tumor vasculature and its response to a therapeutic vascular disrupting agent is described. The scanner employs a Fabry-Perot polymer film ultrasound sensor for mapping the photoacoustic waves and an image reconstruction algorithm based upon attenuation-compensated acoustic time reversal. The system was used to noninvasively image human colorectal tumor xenografts implanted subcutaneously in mice. Label-free three-dimensional in vivo images of whole tumors to depths of almost 10 mm with sub-100-micron spatial resolution were acquired in a longitudinal manner. This enabled the development of tumor-related vascular features, such as vessel tortuosity, feeding vessel recruitment, and necrosis to be visualized over time. The system was also used to study the temporal evolution of the response of the tumor vasculature following the administration of a therapeutic vascular disrupting agent (OXi4503). This revealed the well-known destruction and recovery phases associated with this agent. These studies illustrate the broader potential of this technology as an imaging tool for the preclinical and clinical study of tumors and other pathologies characterized by changes in the vasculature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angiogenesis as a therapeutic target
Ferrara, N., & Kerbel, R. S. (2005) · Nature · doi:10.1038/nature04483 · Cited by 2,653
k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields
Treeby, B. E., & Cox, B. T. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3360308 · Cited by 2,337
Self-citationBiomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Self-citationFunctional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Guidelines for the welfare and use of animals in cancer research
An ad hoc committee of the National Cancer Research Institute, Workman, P., Aboagye, E. O., Balkwill, F., Balmain, A., Bruder, G., Chaplin, D. J., Double, J. A., Everitt, J., Farningham, D. A. H., et al. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605642 · Cited by 1,442
Optical-resolution photoacoustic microscopy for in vivo imaging of single capillaries
Maslov, K., Zhang, H. F., Hu, S., & Wang, L. V. (2008) · Optics Letters · doi:10.1364/ol.33.000929 · Cited by 763
Vakoc, B. J., Lanning, R. M., Tyrrell, J. A., Padera, T. P., Bartlett, L. A., Stylianopoulos, T., Munn, L. L., Tearney, G. J., Fukumura, D., Jain, R. K., et al. (2009) · Nature Medicine · doi:10.1038/nm.1971 · Cited by 719
Therapy-Induced Acute Recruitment of Circulating Endothelial Progenitor Cells to Tumors
Shaked, Y., Ciarrocchi, A., Franco, M., Lee, C. R., Man, S., Cheung, A. M., Hicklin, D. J., Chaplin, D., Foster, F. S., Benezra, R., et al. (2006) · Science · doi:10.1126/science.1127592 · Cited by 570
Photoacoustic tomography in absorbing acoustic media using time reversal
Treeby, B. E., Zhang, E. Z., & Cox, B. T. (2010) · Inverse Problems · doi:10.1088/0266-5611/26/11/115003 · Cited by 354
Self-citationLaufer, J., Delpy, D., Elwell, C., & Beard, P. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/1/010 · Cited by 319
Self-citationIn vivo high-resolution 3D photoacoustic imaging of superficial vascular anatomy
Zhang, E. Z., Laufer, J. G., Pedley, R. B., & Beard, P. C. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/4/014 · Cited by 298
Self-citationTozer, G. M., Prise, V. E., Wilson, J., Čemažar, M., Shan, S., Dewhirst, M. W., Barber, P. R., Vojnovic, B., & Chaplin, D. J. (2001) · PubMed · Cited by 283
Imaging of tumor angiogenesis in rat brains in vivo by photoacoustic tomography
Ku, G., Wang, X., Xie, X., Stoica, G., & Wang, L. V. (2005) · Applied Optics · doi:10.1364/ao.44.000770 · Cited by 219
Serial noninvasive photoacoustic imaging of neovascularization in tumor angiogenesis
Siphanto, R. I., Thumma, K. K., Kolkman, R. G. M., van Leeuwen, T. G., de Mul, F. F. M., van Neck, J. W., van Adrichem, L. N. A., & Steenbergen, W. (2005) · Optics Express · doi:10.1364/opex.13.000089 · Cited by 205
Kiessling, F., Greschus, S., Lichy, M. P., Bock, M., Fink, C., Vosseler, S., Moll, J., Mueller, M. M., Fusenig, N. E., Traupe, H., et al. (2004) · Nature Medicine · doi:10.1038/nm1101 · Cited by 205
In vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth
Yao, J., Maslov, K. I., Shi, Y., Taber, L. A., & Wang, L. V. (2010) · Optics Letters · doi:10.1364/ol.35.001419 · Cited by 200
Zhang, E. Z., Povazay, B., Laufer, J., Alex, A., Hofer, B., Pedley, B., Glittenberg, C., Treeby, B., Cox, B., Beard, P., et al. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.002202 · Cited by 190
Self-citationIntravital imaging of tumour vascular networks using multi-photon fluorescence microscopy
TOZER, G. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.07.015 · Cited by 163
Noninvasive photoacoustic imaging of the developing vasculature during early tumor growth
Lao, Y., Xing, D., Yang, S., & Xiang, L. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/013 · Cited by 153
Laufer, J. G., Zhang, E., Raivich, G., & Beard, P. C. (2009) · Applied Optics · doi:10.1364/ao.48.00d299 · Cited by 141
Self-citationMicro-ultrasound for preclinical imaging
Foster, F. S., Hossack, J. A., & Adamson, S. L. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0037 · Cited by 128
Pedley, R. B., Hill, S. A., Boxer, G., Flynn, A. A., Boden, R. W., Watson, R., Dearling, J. L. J., Chaplin, D. J., & Beǵent, R. H. J. (2001) · PubMed · Cited by 108
Effect of the Second-Generation Vascular Disrupting Agent OXi4503 on Tumor Vascularity
Salmon, H. W., & Siemann, D. W. (2006) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-0163 · Cited by 105
In vivo imaging and characterization of hypoxia-induced neovascularization and tumor invasion
Lungu, G. F., Li, M., Xie, X., Wang, L. V., & Stoica, G. (2007) · International Journal of Oncology · doi:10.3892/ijo.30.1.45 · Cited by 98
Folarin, A., Konerding, M. A., TIMONEN, J., Nagl, S., & Pedley, R. B. (2010) · Microvascular Research · doi:10.1016/j.mvr.2010.03.007 · Cited by 82
Hak, S., Reitan, N. K., Haraldseth, O., & Davies, C. D. L. (2010) · Angiogenesis · doi:10.1007/s10456-010-9176-y · Cited by 72
Predicting Response to Radioimmunotherapy from the Tumor Microenvironment of Colorectal Carcinomas
El‐Emir, E., Qureshi, U., Dearling, J. L. J., Boxer, G. M., Clatworthy, I., Folarin, A., Robson, M. P., Nagl, S., Konerding, M. A., & Pedley, R. B. (2007) · Cancer Research · doi:10.1158/0008-5472.can-07-2967 · Cited by 72
Simultaneous spatial and spectral mapping of flow using photoacoustic Doppler measurement
Sheinfeld, A., Gilead, S., & Eyal, A. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3509113 · Cited by 27
Molecular and Functional MRI of the Tumor Microenvironment
Penet, M., Glunde, K., Jacobs, M. A., Pathak, A. P., & Bhujwalla, Z. M. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.043349 · Cited by 25
Salmon, H. W., Mladinich, C. R. J., & Siemann, D. W. (2006) · European Journal of Cancer · doi:10.1016/j.ejca.2006.06.016 · Cited by 23
Sorg (2010) · Oncology Reports · doi:10.3892/or_00000685 · Cited by 21
Pulsed photoacoustic Doppler flow measurements in blood-mimicking phantoms
Brunker, J., & Beard, P. C. (2011) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.874469 · Cited by 12
Self-citation
Cited by
A practical guide to photoacoustic tomography in the life sciences
Wang, L. V., & Yao, J. (2016) · Nature Methods · doi:10.1038/nmeth.3925 · Cited by 1,394
Contrast agents for molecular photoacoustic imaging
Weber, J., Beard, P. C., & Bohndiek, S. E. (2016) · Nature Methods · doi:10.1038/nmeth.3929 · Cited by 1,270
Self-citationAdvances in real-time multispectral optoacoustic imaging and its applications
Taruttis, A., & Ntziachristos, V. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.29 · Cited by 594
Optical coherence tomography today: speed, contrast, and multimodality
Drexler, W., Liu, M., Kumar, A., Kamali, T., Unterhuber, A., & Leitgeb, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071412 · Cited by 473
Deep in vivo photoacoustic imaging of mammalian tissues using a tyrosinase-based genetic reporter
Jathoul, A. P., Laufer, J., Ogunlade, O., Treeby, B., Cox, B., Zhang, E., Johnson, P., Pizzey, A. R., Philip, B., Marafioti, T., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.22 · Cited by 442
Self-citation
Metadata
- Authors
- Laufer, J. G., Zhang, E. Z., Treeby, B. E., Cox, B. T., Beard, P. C., Johnson, P., & Pedley, B.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2012-05-21
- Volume
- 17
- Issue
- 5
- Pages
- 1
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2016475632
- Cited by
- 308
- References
- 32
- FWCI
- 16.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.