Abstract
The use of a novel all-optical photoacoustic scanner for imaging the development of tumor vasculature and its response to a therapeutic vascular disrupting agent is described. The scanner employs a Fabry-Perot polymer film ultrasound sensor for mapping the photoacoustic waves and an image reconstruction algorithm based upon attenuation-compensated acoustic time reversal. The system was used to noninvasively image human colorectal tumor xenografts implanted subcutaneously in mice. Label-free three-dimensional in vivo images of whole tumors to depths of almost 10 mm with sub-100-micron spatial resolution were acquired in a longitudinal manner. This enabled the development of tumor-related vascular features, such as vessel tortuosity, feeding vessel recruitment, and necrosis to be visualized over time. The system was also used to study the temporal evolution of the response of the tumor vasculature following the administration of a therapeutic vascular disrupting agent (OXi4503). This revealed the well-known destruction and recovery phases associated with this agent. These studies illustrate the broader potential of this technology as an imaging tool for the preclinical and clinical study of tumors and other pathologies characterized by changes in the vasculature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angiogenesis as a therapeutic target
Ferrara, N., & Kerbel, R. S. (2005) · Nature · doi:10.1038/nature04483 · Cited by 2,653
k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields
Treeby, B. E., & Cox, B. T. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3360308 · Cited by 2,337
Self-citationBiomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Self-citationFunctional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging
Zhang, H. F., Maslov, K., Stoica, G., & Wang, L. V. (2006) · Nature Biotechnology · doi:10.1038/nbt1220 · Cited by 1,854
Guidelines for the welfare and use of animals in cancer research
An ad hoc committee of the National Cancer Research Institute, Workman, P., Aboagye, E. O., Balkwill, F., Balmain, A., Bruder, G., Chaplin, D. J., Double, J. A., Everitt, J., Farningham, D. A. H., et al. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605642 · Cited by 1,442
Optical-resolution photoacoustic microscopy for in vivo imaging of single capillaries
Maslov, K., Zhang, H. F., Hu, S., & Wang, L. V. (2008) · Optics Letters · doi:10.1364/ol.33.000929 · Cited by 763
Vakoc, B. J., Lanning, R. M., Tyrrell, J. A., Padera, T. P., Bartlett, L. A., Stylianopoulos, T., Munn, L. L., Tearney, G. J., Fukumura, D., Jain, R. K., et al. (2009) · Nature Medicine · doi:10.1038/nm.1971 · Cited by 719
Therapy-Induced Acute Recruitment of Circulating Endothelial Progenitor Cells to Tumors
Shaked, Y., Ciarrocchi, A., Franco, M., Lee, C. R., Man, S., Cheung, A. M., Hicklin, D. J., Chaplin, D., Foster, F. S., Benezra, R., et al. (2006) · Science · doi:10.1126/science.1127592 · Cited by 570
Photoacoustic tomography in absorbing acoustic media using time reversal
Treeby, B. E., Zhang, E. Z., & Cox, B. T. (2010) · Inverse Problems · doi:10.1088/0266-5611/26/11/115003 · Cited by 354
Self-citationLaufer, J., Delpy, D., Elwell, C., & Beard, P. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/1/010 · Cited by 319
Self-citation
Cited by
A practical guide to photoacoustic tomography in the life sciences
Wang, L. V., & Yao, J. (2016) · Nature Methods · doi:10.1038/nmeth.3925 · Cited by 1,394
Contrast agents for molecular photoacoustic imaging
Weber, J., Beard, P. C., & Bohndiek, S. E. (2016) · Nature Methods · doi:10.1038/nmeth.3929 · Cited by 1,270
Self-citationAdvances in real-time multispectral optoacoustic imaging and its applications
Taruttis, A., & Ntziachristos, V. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.29 · Cited by 594
Optical coherence tomography today: speed, contrast, and multimodality
Drexler, W., Liu, M., Kumar, A., Kamali, T., Unterhuber, A., & Leitgeb, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071412 · Cited by 473
Deep in vivo photoacoustic imaging of mammalian tissues using a tyrosinase-based genetic reporter
Jathoul, A. P., Laufer, J., Ogunlade, O., Treeby, B., Cox, B., Zhang, E., Johnson, P., Pizzey, A. R., Philip, B., Marafioti, T., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.22 · Cited by 442
Self-citationTutorial on photoacoustic tomography
Zhou, Y., Yao, J., & Wang, L. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.061007 · Cited by 421
Structural and functional photoacoustic molecular tomography aided by emerging contrast agents
Nie, L., & Chen, X. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00086b · Cited by 383
Looking at sound: optoacoustics with all-optical ultrasound detection
Wissmeyer, G., Pleitez, M. A., Rosenthal, A., & Ntziachristos, V. (2018) · Light: Science & Applications · doi:10.1038/s41377-018-0036-7 · Cited by 374
Advanced optoacoustic methods for multiscale imaging of in vivo dynamics
Deán-Ben, X. L., Gottschalk, S., Mc Larney, B., Shoham, S., & Razansky, D. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00765a · Cited by 337
Medical Imaging of Microrobots: Toward In Vivo Applications
Aziz, A., Pane, S., Iacovacci, V., Koukourakis, N., Czarske, J., Menciassi, A., Medina-Sánchez, M., & Schmidt, O. G. (2020) · ACS Nano · doi:10.1021/acsnano.0c05530 · Cited by 287
Advanced Photoacoustic Imaging Applications of Near‐Infrared Absorbing Organic Nanoparticles
Jiang, Y., & Pu, K. (2017) · Small · doi:10.1002/smll.201700710 · Cited by 277
Recent Advances in Photoacoustic Imaging for Deep-Tissue Biomedical Applications
Wang, S., Lin, J., Wang, T., Chen, X., & Huang, P. (2016) · Theranostics · doi:10.7150/thno.16715 · Cited by 261
Photoacoustic Microscopy and Computed Tomography: From Bench to Bedside
Wang, L. V., & Gao, L. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104553 · Cited by 246
“Due to its 2D parallel acquisition, phase contrast microscopy is superior to Mach–Zehnder interferometry in terms of imaging speed for OD-PAT (59).”
BackgroundInfluentialChemical Design of Activatable Photoacoustic Probes for Precise Biomedical Applications
Liu, Y., Teng, L., Yin, B., Meng, H., Yin, X., Huan, S., Song, G., & Zhang, X.-B. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00875 · Cited by 245
Acoustic Inversion in Optoacoustic Tomography: A Review
Rosenthal, A., Ntziachristos, V., & Razansky, D. (2014) · Current Medical Imaging Reviews · doi:10.2174/15734056113096660006 · Cited by 236
“Point [25], [26] [32], [33] [10], [39], [40]”
InfluentialPhotoacoustic Imaging for Cancer Detection and Staging
Mehrmohammadi, M., Joon Yoon, S., Yeager, D., & Y. Emelianov, S. (2013) · Current Molecular Imaging · doi:10.2174/2211555211302010010 · Cited by 231
Optoacoustic mesoscopy for biomedicine
Omar, M., Aguirre, J., & Ntziachristos, V. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0377-4 · Cited by 204
Emerging Designs of Activatable Photoacoustic Probes for Molecular Imaging
Miao, Q., & Pu, K. (2016) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.6b00641 · Cited by 173
Strategies for Image-Guided Therapy, Surgery, and Drug Delivery Using Photoacoustic Imaging
Moore, C., & Jokerst, J. V. (2019) · Theranostics · doi:10.7150/thno.32362 · Cited by 169
“used a PA scanner and a time-reversal image reconstruction program to create accurate 3D images of angiogenesis in vivo at depths of nearly 10 mm and with sub-100 μm spatial resolution [169].”
MethodMultiplexed imaging for diagnosis and therapy
Heinzmann, K., Carter, L. M., Lewis, J. S., & Aboagye, E. O. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0131-8 · Cited by 168
Guo, B., Chen, J., Chen, N., Middha, E., Xu, S., Pan, Y., Wu, M., Li, K., Liu, C., & Liu, B. (2019) · Advanced Materials · doi:10.1002/adma.201808355 · Cited by 159
Toward the broad adoption of 3D tumor models in the cancer drug pipeline
Cox, M. C., Reese, L. M., Bickford, L. R., & Verbridge, S. S. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00172 · Cited by 80
de Maar, J. S., Sofias, A. M., Porta Siegel, T., Vreeken, R. J., Moonen, C., Bos, C., & Deckers, R. (2020) · Theranostics · doi:10.7150/thno.38625 · Cited by 71
Metadata
- Authors
- Laufer, J. G., Zhang, E. Z., Treeby, B. E., Cox, B. T., Beard, P. C., Johnson, P., & Pedley, B.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2012-05-21
- Volume
- 17
- Issue
- 5
- Pages
- 1
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2016475632
- Cited by
- 308
- References
- 32
- FWCI
- 16.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.