Widefield quantitative multiplex surface enhanced Raman scattering imaging in vivo
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In recent years numerous studies have shown the potential advantages of molecular imaging in vitro and in vivo using contrast agents based on surface enhanced Raman scattering (SERS), however the low throughput of traditional point-scanned imaging methodologies have limited their use in biological imaging. In this work we demonstrate that direct widefield Raman imaging based on a tunable filter is capable of quantitative multiplex SERS imaging in vivo, and that this imaging is possible with acquisition times which are orders of magnitude lower than achievable with comparable point-scanned methodologies. The system, designed for small animal imaging, has a linear response from (0.01 to 100 pM), acquires typical in vivo images in <10 s, and with suitable SERS reporter molecules is capable of multiplex imaging without compensation for spectral overlap. To demonstrate the utility of widefield Raman imaging in biological applications, we show quantitative imaging of four simultaneous SERS reporter molecules in vivo with resulting probe quantification that is in excellent agreement with known quantities (R²>0.98).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo tumor targeting and spectroscopic detection with surface-enhanced Raman nanoparticle tags
Qian, X., Peng, X.-H., Ansari, D. O., Yin-Goen, Q., Chen, G. Z., Shin, D. M., Yang, L., Young, A. N., Wang, M. D., & Nie, S. (2008) · Nature Biotechnology · doi:10.1038/nbt1377 · Cited by 2,201 · cited 1×
“SERS NPs have been successfully used in ex vivo/serum based assays,(9,13,14) in vitro diagnostics,(10,15,16) and in vivo imaging.(7,8,17,18)”
MethodZavaleta, C. L., Smith, B. R., Walton, I., Doering, W., Davis, G., Shojaei, B., Natan, M. J., & Gambhir, S. S. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813327106 · Cited by 714
The Fate and Toxicity of Raman-Active Silica-Gold Nanoparticles in Mice
Thakor, A. S., Luong, R., Paulmurugan, R., Lin, F. I., Kempen, P., Zavaleta, C., Chu, P., Massoud, T. F., Sinclair, R., & Gambhir, S. S. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3001963 · Cited by 159 · cited 1×
“core material, typically gold for in vivo use, may reduce toxicity concerns as compared to quantum dots.(11,12) SERS NPs have been successfully used in ex vivo/serum based assays,(9,13,14) in vitro diagnostics,(10,15,16) and in vivo imaging.”
BackgroundSpectral Analysis of Multiplex Raman Probe Signatures
Lutz, B. R., Dentinger, C. E., Nguyen, L. N., Sun, L., Zhang, J., Allen, A. N., Chan, S., & Knudsen, B. S. (2008) · ACS Nano · doi:10.1021/nn800243g · Cited by 135 · cited 2×
“11,12 SERS NPs have been successfully used in ex vivo /serum based assays, 9,13,14 in vitro diagnostics, 10,15,16 and in vivo imaging.”
Method
Cited by
SERS Nanoparticles in Medicine: From Label-Free Detection to Spectroscopic Tagging
Lane, L. A., Qian, X., & Nie, S. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00265 · Cited by 873
The many facets of Raman spectroscopy for biomedical analysis
Krafft, C., & Popp, J. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-8311-9 · Cited by 198
“Another Raman system based on SERS and a tunable filter was designed for small animal imaging [103].”
MethodA small animal Raman instrument for rapid, wide-area, spectroscopic imaging
Bohndiek, S. E., Wagadarikar, A., Zavaleta, C. L., Van de Sompel, D., Garai, E., Jokerst, J. V., Yazdanfar, S., & Gambhir, S. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1301379110 · Cited by 133
“Collecting signal from a narrow spectral band, however, sacrifices the rich spectral fingerprint information, possibly reducing detection sensitivity and making both multiplexing and quantification more challenging (13).”
BackgroundWang, Y. W., Kang, S., Khan, A., Bao, P. Q., & Liu, J. T. C. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003714 · Cited by 110
Eremina, O. E., Czaja, A. T., Fernando, A., Aron, A., Eremin, D. B., & Zavaleta, C. (2022) · ACS Nano · doi:10.1021/acsnano.2c00353 · Cited by 88
Metadata
- Authors
- McVeigh, P. Z., Mallia, R. J., Veilleux, I., & Wilson, B. C.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2013-04-16
- Volume
- 18
- Issue
- 4
- Pages
- 046011
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2116327364
- Cited by
- 56
- References
- 4
- FWCI
- 7.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.