Label-free photoacoustic nanoscopy
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Super-resolution microscopy techniques - capable of overcoming the diffraction limit of light - have opened new opportunities to explore subcellular structures and dynamics not resolvable in conventional far-field microscopy. However, relying on staining with exogenous fluorescent markers, these techniques can sometimes introduce undesired artifacts to the image, mainly due to large tagging agent sizes and insufficient or variable labeling densities. By contrast, the use of endogenous pigments allows imaging of the intrinsic structures of biological samples with unaltered molecular constituents. Here, we report label-free photoacoustic (PA) nanoscopy, which is exquisitely sensitive to optical absorption, with an 88 nm resolution. At each scanning position, multiple PA signals are successively excited with increasing laser pulse energy. Because of optical saturation or nonlinear thermal expansion, the PA amplitude depends on the nonlinear incident optical fluence. The high-order dependence, quantified by polynomial fitting, provides super-resolution imaging with optical sectioning. PA nanoscopy is capable of super-resolution imaging of either fluorescent or nonfluorescent molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488 · cited 1×
“Optically Sectioned PA Nanoscopy of Red Blood Cells and Mitochondria in Fibroblasts Finally, the nonlinear PA effects also provide optical sectioning, as in multiphoton microscopy, 30”
BackgroundImaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772 · cited 1×
“2–7 Some of the techniques utilize nonlinear effects to narrow the point spread function (PSF);3–5 others use stochastic activation and averaging to localize individual fluorescent molecules.(6,7) These fluorescence-based nanoscopy methods have improved both lateral and axial resolution by an order of magnitude over c…”
BackgroundSub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078 · cited 1×
“2–7 Some of the techniques utilize nonlinear effects to narrow the point spread function (PSF);3–5 others use stochastic activation and averaging to localize individual fluorescent molecules.(6,7) These fluorescence-based nanoscopy methods have improved both lateral and axial resolution by an order of magnitude over c…”
BackgroundHell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065 · cited 1×
“7 Some of the techniques utilize nonlinear effects to narrow the point spread function (PSF); 3 – 5 others use stochastic activation and averaging to localize individual fluorescent molecules.”
MethodPhotoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331 · cited 2×
“tional and molecular imaging tool based on optical absorption contrast.(11,12) In the PA phenomenon, light is absorbed by molecules and converted to heat.”
BackgroundMethodSelf-citationChen, H., Detmer, S. A., Ewald, A. J., Griffin, E. E., Fraser, S. E., & Chan, D. C. (2003) · The Journal of Cell Biology · doi:10.1083/jcb.200211046 · Cited by 2,601 · cited 1×
“To demonstrate PA nanoscopy’s ability to resolve different morphometries of mitochondria, we imaged genetically modified MEFs in which the normal interconnected mitochondrial network is fragmented to various degrees through ablation of one or both Mitofusin (Mfn) genes.(29) The mitochondria in wild-type MEF cells show…”
BackgroundGustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224 · cited 1×
“7 Some of the techniques utilize nonlinear effects to narrow the point spread function (PSF); 3 – 5 others use stochastic activation and averaging to localize individual fluorescent molecules.”
MethodSuper-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Multiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400 · cited 1×
“tional and molecular imaging tool based on optical absorption contrast.(11,12) In the PA phenomenon, light is absorbed by molecules and converted to heat.”
MethodSelf-citationCoherent Anti-Stokes Raman Scattering Microscopy: Chemical Imaging for Biology and Medicine
Evans, C. L., & Xie, X. S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112754 · Cited by 1,150 · cited 1×
“33,34 The nonlinearity can be used to accentuate spatial gradients of molecule concentration.”
Cited by
A practical guide to photoacoustic tomography in the life sciences
Wang, L. V., & Yao, J. (2016) · Nature Methods · doi:10.1038/nmeth.3925 · Cited by 1,394
Self-citationSuper-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Photoacoustic clinical imaging
Steinberg, I., Huland, D. M., Vermesh, O., Frostig, H. E., Tummers, W. S., & Gambhir, S. S. (2019) · Photoacoustics · doi:10.1016/j.pacs.2019.05.001 · Cited by 553
Tutorial on photoacoustic tomography
Zhou, Y., Yao, J., & Wang, L. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.061007 · Cited by 421
Self-citationAdvanced optoacoustic methods for multiscale imaging of in vivo dynamics
Deán-Ben, X. L., Gottschalk, S., Mc Larney, B., Shoham, S., & Razansky, D. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00765a · Cited by 337
Recent advances toward preclinical and clinical translation of photoacoustic tomography: a review
Upputuri, P. K., & Pramanik, M. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.4.041006 · Cited by 223
Photoacoustic imaging in the second near-infrared window: a review
Upputuri, P. K., & Pramanik, M. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.4.040901 · Cited by 209
Cao, R., Nelson, S. D., Davis, S., Liang, Y., Luo, Y., Zhang, Y., Crawford, B., & Wang, L. V. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00940-z · Cited by 177
Self-citationTzang, O., & Piestun, R. (2016) · Optics Express · doi:10.1364/oe.24.028122 · Cited by 32
Metadata
- Authors
- Danielli, A., Maslov, K. I., Garcia-Uribe, A., Winkler, A. M., Li, C., Wang, L., Chen, Y., Dorn, G. W., & Wang, L. V.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2014-08-07
- Volume
- 19
- Issue
- 08
- Pages
- 1
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2068638954
- Cited by
- 160
- References
- 24
- FWCI
- 8.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.