Methods and algorithms for optical coherence tomography-based angiography: a review and comparison
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Optical coherence tomography (OCT)-based angiography is increasingly becoming a clinically useful and important imaging technique due to its ability to provide volumetric microvascular networks innervating tissue beds in vivo without a need for exogenous contrast agent. Numerous OCT angiography algorithms have recently been proposed for the purpose of contrasting microvascular networks. A general literature review is provided on the recent progress of OCT angiography methods and algorithms. The basic physics and mathematics behind each method together with its contrast mechanism are described. Potential directions for future technical development of OCT based angiography is then briefly discussed. Finally, by the use of clinical data captured from normal and pathological subjects, the imaging performance of vascular networks delivered by the most recently reported algorithms is evaluated and compared, including optical microangiography, speckle variance,phase variance, split-spectrum amplitude decorrelation angiography, and correlation mapping. It is found that the method that utilizes complex OCT signal to contrast retinal blood flow delivers the best performance among all the algorithms in terms of image contrast and vessel connectivity. The purpose of this review is to help readers understand and select appropriate OCT angiography algorithm for use in specific applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Global prevalence and major risk factors of diabetic retinopathy
Yau, J. W. Y., Rogers, S. L., Kawasaki, R., Lamoureux, E. L., Kowalski, J. W., Bek, T., Chen, S.-J., Dekker, J. M., Fletcher, A., Grauslund, J., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1909 · Cited by 4,985 · cited 1×
“The DR is a leading cause of blindness in American adults.(78) The fluorescein angiogram of the patient was illustrated in Fig.”
BackgroundDigital Spectral Analysis with Applications
Marple, S. L., & Carey, W. M. (1989) · The Journal of the Acoustical Society of America · doi:10.1121/1.398548 · Cited by 1,984
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
Digital spectral analysis : with applications
Marple, S. L. (1987) · International Linear Collider · Cited by 1,732
The impact of ocular blood flow in glaucoma
Flammer, J., Orgül, S., Costa, V. P., Orzalesi, N., Krieglstein, G. K., Serra, L. M., Renard, J.-P., & Stefánsson, E. (2002) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00008-3 · Cited by 1,709
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
Laser speckle contrast imaging in biomedical optics
Boas, D. A., & Dunn, A. K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3285504 · Cited by 1,122
Speckle in Optical Coherence Tomography
Schmitt, J. M., Xiang, S. H., & Yung, K. M. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429925 · Cited by 837
Vakoc, B. J., Lanning, R. M., Tyrrell, J. A., Padera, T. P., Bartlett, L. A., Stylianopoulos, T., Munn, L. L., Tearney, G. J., Fukumura, D., Jain, R. K., et al. (2009) · Nature Medicine · doi:10.1038/nm.1971 · Cited by 719
Speckle variance detection of microvasculature using swept-source optical coherence tomography
Mariampillai, A., Standish, B. A., Moriyama, E. H., Khurana, M., Munce, N. R., Leung, M. K. K., Jiang, J., Cable, A., Wilson, B. C., Vitkin, I. A., et al. (2008) · Optics Letters · doi:10.1364/ol.33.001530 · Cited by 699
Jia, Y., Bailey, S. T., Hwang, T. S., McClintic, S. M., Gao, S. S., Pennesi, M. E., Flaxel, C. J., Lauer, A. K., Wilson, D. J., Hornegger, J., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1500185112 · Cited by 665
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Self-citationThree dimensional optical angiography
Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A. (2007) · Optics Express · doi:10.1364/oe.15.004083 · Cited by 627
Self-citationIzatt, J. A., Kulkarni, M. D., Yazdanfar, S., Barton, J. K., & Welch, A. J. (1997) · Optics Letters · doi:10.1364/ol.22.001439 · Cited by 609
Makita, S., Hong, Y., Yamanari, M., Yatagai, T., & Yasuno, Y. (2006) · Optics Express · doi:10.1364/oe.14.007821 · Cited by 594
Handbook of Optical Coherence Tomography
(2001) · CRC Press eBooks · doi:10.1201/b14024 · Cited by 580
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Optical coherence tomography today: speed, contrast, and multimodality
Drexler, W., Liu, M., Kumar, A., Kamali, T., Unterhuber, A., & Leitgeb, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071412 · Cited by 473
White, B. R., Pierce, M. C., Nassif, N., Cense, B., Park, B. H., Tearney, G. J., Bouma, B. E., Chen, T. C., & de Boer, J. F. (2003) · Optics Express · doi:10.1364/oe.11.003490 · Cited by 457
Optical Coherence Tomography of Age-related Macular Degeneration and Choroidal Neovascularization
Hee, M. R., Baumal, C. R., Puliafito, C. A., Duker, J. S., Reichel, E., Wilkins, J. R., Coker, J. G., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30512-5 · Cited by 416
Wang, R. K., An, L., Francis, P., & Wilson, D. J. (2010) · Optics Letters · doi:10.1364/ol.35.001467 · Cited by 355
Self-citationDiabetic Retinopathy: Targeting Vasoregression
Hammes, H.-P., Feng, Y., Pfister, F., & Brownlee, M. (2011) · Diabetes · doi:10.2337/db10-0454 · Cited by 347
An, L., Qin, J., & Wang, R. K. (2010) · Optics Express · doi:10.1364/oe.18.008220 · Cited by 291
Self-citationOptical coherence tomography in dermatology
Sattler, E., Kästle, R., & Welzel, J. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.061224 · Cited by 283
Doppler optical micro-angiography for volumetric imaging of vascular perfusion in vivo
Wang, R. K., & An, L. (2009) · Optics Express · doi:10.1364/oe.17.008926 · Cited by 220
Self-citationHuang, Y., Zhang, Q., Thorell, M. R., An, L., Durbin, M. K., Laron, M., Sharma, U., Gregori, G., Rosenfeld, P. J., & Wang, R. K. (2014) · Ophthalmic Surgery, Lasers and Imaging Retina · doi:10.3928/23258160-20140909-08 · Cited by 210
Self-citationWang, Y., Bower, B. A., Izatt, J. A., Tan, O., & Huang, D. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2998480 · Cited by 182
Jonathan, E., Enfield, J., & Leahy, M. J. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201000103 · Cited by 164
Rapid volumetric angiography of cortical microvasculature with optical coherence tomography
Srinivasan, V. J., Jiang, J. Y., Yaseen, M. A., Radhakrishnan, H., Wu, W., Barry, S., Cable, A. E., & Boas, D. A. (2010) · Optics Letters · doi:10.1364/ol.35.000043 · Cited by 159
In vivo full range complex Fourier domain optical coherence tomography
Wang, R. K. (2007) · Applied Physics Letters · doi:10.1063/1.2437682 · Cited by 151
Self-citationDrexler, W. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-374203-2.00247-5 · Cited by 143
Doppler variance imaging for three-dimensional retina and choroid angiography
Yu, L., & Chen, Z. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3302806 · Cited by 136
User-guided segmentation for volumetric retinal optical coherence tomography images
Yin, X., Chao, J. R., & Wang, R. K. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.8.086020 · Cited by 128
Self-citationWang, R. K., & Hurst, S. (2007) · Optics Express · doi:10.1364/oe.15.011402 · Cited by 124
Self-citationLiew, Y. M., McLaughlin, R. A., Gong, P., Wood, F. M., & Sampson, D. D. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.061213 · Cited by 103
Wang, Y., Fawzi, A. A., Tan, O., Gil-Flamer, J. H., & Huang, D. (2009) · Optics Express · doi:10.1364/oe.17.004061 · Cited by 91
Optical coherence tomography: Technology and applications
Drexler, W. (2013) · Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC) · doi:10.1109/cleoe-iqec.2013.6802013 · Cited by 88
Baran, U., Li, Y., Choi, W. J., Kalkan, G., & Wang, R. K. (2015) · Lasers in Surgery and Medicine · doi:10.1002/lsm.22339 · Cited by 60
Self-citationMacro-to-micro cortical vascular imaging underlies regional differences in ischemic brain
Dziennis, S., Qin, J., Shi, L., & Wang, R. K. (2015) · Scientific Reports · doi:10.1038/srep10051 · Cited by 31
Self-citation
Cited by
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Self-citationAge-related macular degeneration
Guymer, R. H., & Campbell, T. G. (2023) · The Lancet · doi:10.1016/s0140-6736(22)02609-5 · Cited by 502
Optical coherence tomography based angiography [Invited]
Chen, C.-L., & Wang, R. K. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001056 · Cited by 415
Self-citationMammo, Z., Heisler, M., Balaratnasingam, C., Lee, S., Yu, D.-Y., Mackenzie, P., Schendel, S., Merkur, A., Kirker, A., Albiani, D., et al. (2016) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2016.07.015 · Cited by 179
Optical coherence tomography angiography: a review of current and future clinical applications
Ang, M., Tan, A. C. S., Cheung, C. M. G., Keane, P. A., Dolz-Marco, R., Sng, C. C. A., & Schmetterer, L. (2018) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-017-3896-2 · Cited by 166
“intravenously administer fluorescent dyes [4, 5].”
Metadata
- Authors
- Zhang, A., Zhang, Q., Chen, C.-L., & Wang, R. K.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2015-10-16
- Volume
- 20
- Issue
- 10
- Pages
- 100901
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W1932853004
- Cited by
- 371
- References
- 40
- FWCI
- 19.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.