Mueller matrix microscope: a quantitative tool to facilitate detections and fibrosis scorings of liver cirrhosis and cancer tissues
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Today the increasing cancer incidence rate is becoming one of the biggest threats to human health.Among all types of cancers, liver cancer ranks in the top five in both frequency and mortality rate all over the world. During the development of liver cancer, fibrosis often evolves as part of a healing process in response to liver damage, resulting in cirrhosis of liver tissues. In a previous study, we applied the Mueller matrix microscope to pathological liver tissue samples and found that both the Mueller matrix polar decomposition (MMPD) and Mueller matrix transformation (MMT) parameters are closely related to the fibrous microstructures. In this paper,we take this one step further to quantitatively facilitate the fibrosis detections and scorings of pathological liver tissue samples in different stages from cirrhosis to cancer using the Mueller matrix microscope. The experimental results of MMPD and MMT parameters for the fibrotic liver tissue samples in different stages are measured and analyzed. We also conduct Monte Carlo simulations based on the sphere birefringence model to examine in detail the influence of structural changes in different fibrosis stages on the imaging parameters. Both the experimental and simulated results indicate that the polarized light microscope and transformed Mueller matrix parameter scan provide additional quantitative information helpful for fibrosis detections and scorings of liver cirrhosis and cancers. Therefore, the polarized light microscope and transformed Mueller matrix parameters have a good application prospect in liver cancer diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rahib, L., Smith, B. D., Aizenberg, R., Rosenzweig, A. B., Fleshman, J. M., & Matrisian, L. M. (2014) · Cancer Research · doi:10.1158/0008-5472.can-14-0155 · Cited by 7,094 · cited 1×
“According to the mortality rate in the United States, liver cancer will become the third leading cause of cancer-related death by 2030.(23) In China, there are over 350,000 new cases of liver cancer each year, accounting for more than 50% of those in the world.”
BackgroundPrimary liver cancer: Worldwide incidence and trends
Bosch, F. X., Ribes, J., Díaz, M., & Cléries, R. (2004) · Gastroenterology · doi:10.1053/j.gastro.2004.09.011 · Cited by 2,477 · cited 1×
“In high-risk countries including China, liver cancer can arise before the age of 20 years.(21,22) According to the mortality rate in the United States, liver cancer will become the third leading cause of cancer-related death by 2030.”
BackgroundSampling Variability of Liver Fibrosis in Chronic Hepatitis C
Bedossa, P., Dargère, D., & Paradis, V. (2003) · Hepatology · doi:10.1016/j.hep.2003.09.022 · Cited by 2,376 · cited 1×
“This procedure needs stained tissue sections and experienced pathologists to result in accurate evaluations.(27) Recently, the second-harmonic generation (SHG) technique has been applied for quantitative assessment of fibrosis in chronic hepatitis B patients.”
Diagnosis, management, and treatment of hepatitis C†
Strader, D. B., Wright, T., Thomas, D. L., & Seeff, L. B. (2004) · Hepatology · doi:10.1002/hep.20119 · Cited by 1,709 · cited 1×
“The diagnosis of liver fibrosis is usually based on histological findings of liver biopsy observed by optical microscope.(26) This procedure needs stained tissue sections and experienced pathologists to result in accurate evaluations.”
BackgroundInterpretation of Mueller matrices based on polar decomposition
Lu, S.-Y., & Chipman, R. A. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.001106 · Cited by 1,409 · cited 1×
“Through calculations using the Mueller matrix polar decomposition (MMPD) andMueller matrix transformation (MMT), groups of quantitative polarization imaging parameters with explicit physics meanings can be obtained.(19,20) Nowadays the increasing cancer incidence rate is becoming one of the biggest threats to human he…”
MethodEpidemiology of Primary Liver Cancer
Bosch, F., Ribes, J., & Borràs, J. (1999) · Seminars in Liver Disease · doi:10.1055/s-2007-1007117 · Cited by 958
Tissue polarimetry: concepts, challenges, applications, and outlook
Ghosh, N. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3652896 · Cited by 740
Detection of preinvasive cancer cells
Backman, V., Wallace, M. B., Perelman, L. T., Arendt, J. T., Gurjar, R., Müller, M. G., Zhang, Q., Zonios, G., Kline, E., McGillican, T., et al. (2000) · Nature · doi:10.1038/35017638 · Cited by 621
Imaging skin pathology with polarized light
Jacques, S. L., Ramella-Roman, J. C., & Lee, K. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1484498 · Cited by 582 · cited 1×
“the past two decades, several techniques such as the degree of polarization and difference polarization have been applied to the detection of human skin cancers in vivo.(7,8) Recently, as”
MethodPhotopolarimetric measurement of the Mueller matrix by Fourier analysis of a single detected signal
Azzam, R. M. A. (1978) · Optics Letters · doi:10.1364/ol.2.000148 · Cited by 500
Cited by
Polarisation optics for biomedical and clinical applications: a review
He, C., He, H., Chang, J., Chen, B., Ma, H., & Booth, M. J. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00639-x · Cited by 604
Self-citationHe, H., Liao, R., Zeng, N., Li, P., Chen, Z., Liu, X., & Ma, H. (2019) · Journal of Lightwave Technology · doi:10.1109/jlt.2018.2868845 · Cited by 204
“Using the modulus designed Mueller matrix microscope, we take one step further to quantitatively facilitate the fibrosis detections and scorings of pathological liver tissue samples in stages F1 to F4 from cirrhosis to cancer [59].”
BackgroundMethodSelf-citation
Metadata
- Authors
- Wang, Y., He, H., Chang, J., He, C., Liu, S., Li, M., Zeng, N., Wu, J., & Ma, H.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2016-04-18
- Volume
- 21
- Issue
- 7
- Pages
- 071112
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2338658261
- Cited by
- 177
- References
- 35
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.