Optical coherence elastography in ophthalmology
Open accessThe DOI matches its Crossref record; 99 of the 99 references it cites were found in a registry or an index.
Abstract
Optical coherence elastography (OCE) can provide clinically valuable information based on local measurements of tissue stiffness. Improved light sources and scanning methods in optical coherence tomography (OCT) have led to rapid growth in systems for high-resolution, quantitative elastography using imaged displacements and strains within soft tissue to infer local mechanical properties. We describe in some detail the physical processes underlying tissue mechanical response based on static and dynamic displacement methods. Namely, the assumptions commonly used to interpret displacement and strain measurements in terms of tissue elasticity for static OCE and propagating wave modes in dynamic OCE are discussed with the ultimate focus on OCT system design for ophthalmic applications. Practical OCT motion-tracking methods used to map tissue elasticity are also presented to fully describe technical developments in OCE, particularly noting those focused on the anterior segment of the eye. Clinical issues and future directions are discussed in the hope that OCE techniques will rapidly move forward to translational studies and clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanical Behavior of Materials
Meyers, M. A., & Chawla, K. K. (2008) · Cambridge University Press eBooks · doi:10.1017/cbo9780511810947 · Cited by 3,376
Rabinowitz, Y. S. (1998) · Survey of Ophthalmology · doi:10.1016/s0039-6257(97)00119-7 · Cited by 2,744
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116 · cited 1×
“ARF delivered by an ultrasound transducer acoustically coupled to tissue has been used to induce displacements in various forms of elastography.(18,22,27,29,39,55,56,92) US radiation force is commonly used in US-based elastography to remotely generate shear waves deep within tissue, and has been applied to OCE (see Fi…”
MethodCorneal Collagen Crosslinking: A Systematic Review
Sorkin, N., & Varssano, D. (2014) · Ophthalmologica · doi:10.1159/000357979 · Cited by 1,918
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103 · cited 2×
“97,98 95, where I is the acoustic intensity of the pump beam, α is the ultrasound absorption coefficient, and C l is the speed of sound.”
BackgroundWollensak, G., Spoerl, E., & Seiler, T. (2003) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(03)00407-3 · Cited by 1,024
A 48-Year Clinical and Epidemiologic Study of Keratoconus
Kennedy, R. H., Bourne, W. M., & Dyer, J. A. (1986) · American Journal of Ophthalmology · doi:10.1016/0002-9394(86)90817-2 · Cited by 966 · cited 1×
“154 – 156 Curvature, elevation, and pachymetric changes are secondary signs of keratoconus, so early detection enabling effective treatment is not possible with current screening tools and may only be possible with a personalized biomechanical model based on spatial maps of fundamental material…”
BackgroundOn the feasibility of remote palpation using acoustic radiation force
Nightingale, K. R., Palmeri, M. L., Nightingale, R. W., & Trahey, G. E. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1378344 · Cited by 731
Cited by
Optical coherence tomography (OCT): principle and technical realization
Aumann, S., Donner, S., Fischer, J., & Müller, F. (2019) · High Resolution Imaging in Microscopy and Ophthalmology · doi:10.1007/978-3-030-16638-0_3 · Cited by 449
Metadata
- Authors
- Kirby, M. A., Pelivanov, I., Song, S., Ambrozinski, Ł., Yoon, S. J., Gao, L., Li, D., Shen, T. T., Wang, R. K., & O’Donnell, M.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2017-12-23
- Volume
- 22
- Issue
- 12
- Pages
- 1
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2778552376
- Cited by
- 228
- References
- 99
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.