Spatial frequency domain imaging in 2019: principles, applications, and perspectives
Open accessThe DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
Spatial frequency domain imaging (SFDI) has witnessed very rapid growth over the last decade, owing to its unique capabilities for imaging optical properties and chromophores over a large field-of-view and in a rapid manner. We provide a comprehensive review of the principles of this imaging method as of 2019, review the modeling of light propagation in this domain, describe acquisition methods, provide an understanding of the various implementations and their practical limitations, and finally review applications that have been published in the literature. Importantly, we also introduce a group effort by several key actors in the field for the dissemination of SFDI, including publications, advice in hardware and implementations, and processing code, all freely available online.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,324
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
Quantitation and mapping of tissue optical properties using modulated imaging
Cuccia, D. J., Bevilacqua, F., Durkin, A. J., Ayers, F. R., & Tromberg, B. J. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3088140 · Cited by 655 · cited 8×
“In particular, these instrumental factors can limit the frequency range used, as the signal-to-noise ratio greatly decreases with spatial frequency.(1,39) Although the specific requirements of tolerances will depend on the objectives of a specific project, in general data should be as clean and noise-free as possible…”
BackgroundMethodInfluentialSelf-citationCuccia, D. J., Bevilacqua, F., Durkin, A. J., & Tromberg, B. J. (2005) · Optics Letters · doi:10.1364/ol.30.001354 · Cited by 429 · cited 2×
“43 Images with depth-sensitive contrast can then be generated using the recovered diffuse reflectance and knowing the spatial frequency used.”
BackgroundMethodSelf-citationNoninvasive determination of the optical properties of two-layered turbid media
Kienle, A., Patterson, M. S., Dögnitz, N., Bays, R., Wagnières, G., & van den Bergh, H. (1998) · Applied Optics · doi:10.1364/ao.37.000779 · Cited by 294
First-in-human pilot study of a spatial frequency domain oxygenation imaging system
Gioux, S., Stockdale, A., Oketokoun, R., Ashitate, Y., Durr, N. J., Moffitt, L. A., Frangioni, J. V., Mazhar, A., Tromberg, B. J., Durkin, A. J., et al. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3614566 · Cited by 166 · cited 3×
“For instance, it has been demonstrated that choosing 650 and 860 nm was optimal to determine oxyhemoglobin and deoxyhemoglobin concentrations.(14,66) It should be noted that this method typically measures what is referred to as “tissue molar concentration,” noted with the prefix “ct” (e.”
MethodSelf-citationThree-dimensional surface profile intensity correction for spatially modulated imaging
Gioux, S., Mazhar, A., Cuccia, D. J., Durkin, A. J., Tromberg, B. J., & Frangioni, J. V. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3156840 · Cited by 161 · cited 4×
“These systems are a combination of benchtop imaging systems with some being transportable to preclinical or clinical sites, as well as improved methods for robust measurement during clinical conditions [motion correction and three-dimensional (3-D) correction].(26,27) 2.”
BackgroundMethodInfluentialSelf-citationKonecky, S. D., Mazhar, A., Cuccia, D. J., Durkin, A. J., Schotland, J. C., & Tromberg, B. J. (2009) · Optics Express · doi:10.1364/oe.17.014780 · Cited by 140
Self-citationWavelength optimization for rapid chromophore mapping using spatial frequency domain imaging
Mazhar, A., Dell, S., Cuccia, D. J., Gioux, S., Durkin, A. J., Frangioni, J. V., & Tromberg, B. J. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3523373 · Cited by 136 · cited 1×
“For instance, it has been demonstrated that choosing 650 and 860 nm was optimal to determine oxyhemoglobin and deoxyhemoglobin concentrations.(14,66) It should be noted that this method typically measures what is referred to as “tissue molar concentration,” noted with the prefix “ct” (e.”
MethodSelf-citationIn Vivo Multiphoton NADH Fluorescence Reveals Depth-Dependent Keratinocyte Metabolism in Human Skin
Balu, M., Mazhar, A., Hayakawa, C. K., Mittal, R., Krasieva, T. B., König, K., Venugopalan, V., & Tromberg, B. J. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2012.11.3809 · Cited by 133
Self-citationSpatial frequency domain imaging of burn wounds in a preclinical model of graded burn severity
Nguyen, J. Q., Crouzet, C., Tuan, A., Riola, K., Uchitel, D., Liaw, L. L., Bernal, N. P., Ponticorvo, A., Choi, B., & Durkin, A. J. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.066010 · Cited by 117
Abookasis, D., Lay, C. C., Mathews, M. S., Linskey, M. E., Frostig, R. D., & Tromberg, B. J. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3116709 · Cited by 103
Ponticorvo, A., Burmeister, D. M., Yang, B. Y., Choi, B., Christy, R. J., & Durkin, A. J. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003467 · Cited by 99
Determination of tissue optical properties by steady-state spatial frequency-domain reflectometry
D�gnitz, N., & Wagni�res, G. (1998) · Lasers in Medical Science · doi:10.1007/bf00592960 · Cited by 98 · cited 1×
“Multiple approaches have been developed for analyzing SFD signals to determine homogeneous or spatially resolved optical properties, including least-squares methods, 2,43 LUTs, 1,44 machine learning and deep learning, 40,45 and data matching to empirical phantom grids.”
MethodSpectral discrimination of breast pathologies in situusing spatial frequency domain imaging
Laughney, A. M., Krishnaswamy, V., Rizzo, E. J., Schwab, M. C., Barth, R. J., Cuccia, D. J., Tromberg, B. J., Paulsen, K. D., Pogue, B. W., & Wells, W. A. (2013) · Breast Cancer Research · doi:10.1186/bcr3455 · Cited by 95
Self-citationDiffraction tomography for biochemical imaging with diffuse-photon density waves
Li, X. D., Durduran, T., Yodh, A. G., Chance, B., & Pattanayak, D. N. (1997) · Optics Letters · doi:10.1364/ol.22.000573 · Cited by 93
Rohrbach, D. J., Muffoletto, D. P., Huihui, J., Saager, R. B., Keymel, K., Paquette, A. D., Morgan, J., Zeitouni, N. C., & Sunar, U. (2014) · Academic Radiology · doi:10.1016/j.acra.2013.11.013 · Cited by 90 · cited 1×
“Another example is the imaging of absorption and scattering properties of skin for the diagnosis of nonmelanoma cancer.(15,19) Skin characterization using SFDI has also been used to quantify different layers of skin to gain insight into the structure.”
MethodErickson, T. A., Mazhar, A., Cuccia, D. J., Durkin, A. J., & Tunnell, J. W. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3431728 · Cited by 88 · cited 2×
“This method is called the LUT method.(1,46)”
MethodSelf-citationStructured illumination enhances resolution and contrast in thick tissue fluorescence imaging
Mazhar, A., Cuccia, D. J., Gioux, S., Durkin, A. J., Frangioni, J. V., & Tromberg, B. J. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3299321 · Cited by 84
Self-citationKanick, S. C., McClatchy, D. M., Krishnaswamy, V., Elliott, J. T., Paulsen, K. D., & Pogue, B. W. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003376 · Cited by 82 · cited 2×
“…not only the absorption and reduced scattering coefficients at small spatial scales, but also the scattering coefficient itself and multiple moments of the phase function, allowing measurements of structural parameters at a sub-mm range, 11,12 and assessment of sampling depths on mesoscopic scales.”
Lin, A. J., Koike, M. A., Green, K. N., Kim, J. G., Mazhar, A., Rice, T. B., LaFerla, F. M., & Tromberg, B. J. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0269-6 · Cited by 79
Self-citationBurmeister, D. M., Ponticorvo, A., Yang, B. Y., Becerra, S. C., Choi, B., Durkin, A. J., & Christy, R. J. (2015) · Burns · doi:10.1016/j.burns.2015.03.001 · Cited by 78
Saager, R. B., Balu, M., Crosignani, V., Sharif, A., Durkin, A. J., Kelly, K. M., & Tromberg, B. J. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.6.066005 · Cited by 76
Weber, J. R., Durkin, A. J., Tromberg, B. J., Cuccia, D. J., Johnson, W. R., Wilson, D. W., Bearman, G. H., Hsu, M., Lin, A., & Binder, D. K. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3528628 · Cited by 76
Self-citationWeber, J. R., Cuccia, D. J., Durkin, A. J., & Tromberg, B. J. (2009) · Journal of Applied Physics · doi:10.1063/1.3116135 · Cited by 71
Self-citationSaager, R. B., Cuccia, D. J., & Durkin, A. J. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3299322 · Cited by 70
Self-citationSaager, R. B., Truong, A., Cuccia, D. J., & Durkin, A. J. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3597621 · Cited by 65
Self-citationSpatial frequency domain tomography of protoporphyrin IX fluorescence in preclinical glioma models
Konecky, S. D., Owen, C. M., Rice, T., Valdés, P. A., Kolste, K., Wilson, B. C., Leblond, F., Roberts, D. W., Paulsen, K. D., & Tromberg, B. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.056008 · Cited by 65
Mazhar, A., Saggese, S., Pollins, A. C., Cardwell, N. L., Nanney, L. B., & Cuccia, D. J. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.8.086019 · Cited by 65
Self-citationNadeau, K. P., Durkin, A. J., & Tromberg, B. J. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.5.056013 · Cited by 65 · cited 1×
“, relies on acquiring one DC planar illumination, along with a single-phase spatially modulated sinewave.(30) The DC planar illumination is then used to extract the MAC at 0 mm−1 and subtracted from the spatially modulated image, which is then processed in the Fourier domain to extract the MAC at a higher spatial freq…”
MethodNguyen, J., Lin, S. J., Tobias, A. M., Gioux, S., Mazhar, A., Cuccia, D. J., Ashitate, Y., Stockdale, A., Oketokoun, R., Durr, N. J., et al. (2013) · Annals of Plastic Surgery · doi:10.1097/sap.0b013e31828b02fb · Cited by 60 · cited 1×
“involving three patients established the capability of SFDI to work under the constraint of flap transplantation surgeries.(107)”
BackgroundSelf-citationZhao, Y., Deng, Y. C., Bao, F., Peterson, H. M., Istfan, R., & Roblyer, D. M. (2018) · Optics Letters · doi:10.1364/ol.43.005669 · Cited by 59 · cited 1×
“Multispatial frequency processing codes were developed to take into account this effect in cases where divergence is significant, such as within an endoscope.(16,40) Finally, many other sources of errors such as camera linearity, projection linearity, and source stability, as in any optical design should be taken into…”
BackgroundQuantitative real-time optical imaging of the tissue metabolic rate of oxygen consumption
Ghijsen, M. T., Lentsch, G. R., Gioux, S., Brenner, M., Durkin, A. J., Choi, B., & Tromberg, B. J. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.3.036013 · Cited by 56 · cited 2×
“, The concept has been extended to real-time measurements using SSOP combined with speckle flow measurement into coherent-SSOP (c-SSOP), which has been validated onto arm-cuff occlusions in human subject and is now tested clinically.(83,84)”
MethodSelf-citationOptical sampling depth in the spatial frequency domain
Hayakawa, C. K., Karrobi, K., Pera, V., Roblyer, D. M., & Venugopalan, V. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.7.071603 · Cited by 56 · cited 1×
“moments of the phase function, allowing measurements of structural parameters at a sub-mm range,(11,12) and assessment of sampling depths on mesoscopic scales.(13) Fig.”
BackgroundGeneralized mesh-based Monte Carlo for wide-field illumination and detection via mesh retessellation
Yao, R., Intes, X., & Fang, Q. (2015) · Biomedical Optics Express · doi:10.1364/boe.7.000171 · Cited by 56 · cited 1×
“done with higher-order anisotropic diffusion models, such as with “δ-P1” solutions), or tallied directly in the frequency domain.(1,8,10) Further, these methods allow to measure not only”
MethodSunar, U., Rohrbach, D. J., Morgan, J., Zeitouni, N., & Henderson, B. W. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.000531 · Cited by 55 · cited 1×
“One of the main applications for this is PpIX fluorescence guided resection in both glioma models and nonmelanoma cancers.(23,25,73,108) Recent work by Valdes et al.”
MethodGreening, G. J., Istfan, R., Higgins, L. M., Balachandran, K., Roblyer, D. M., Pierce, M. C., & Muldoon, T. J. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.11.115002 · Cited by 54 · cited 1×
“Multiple groups have depended on SFDI as a tool to characterize calibration phantoms and validate new fabrication methods.(130,131) Konecky et al.”
MethodLaughney, A. M., Krishnaswamy, V., Rice, T. B., Cuccia, D. J., Barth, R. J., Tromberg, B. J., Paulsen, K. D., Pogue, B. W., & Wells, W. A. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.3.036012 · Cited by 54 · cited 1×
“The main goal for this is work is to enable intraoperative assessment of lumpectomy margins by differentiating between normal, fibroadenoma, ductal carcinoma in situ (DCIS), and invasive cancer.(109,110) Recently, the development of subdiffuse SFDI has shown an even stronger potential for highlighting structural chang…”
BackgroundSelf-citationPonticorvo, A., Rowland, R. A., Baldado, M. L., Burmeister, D. M., Christy, R. J., Bernal, N. P., & Durkin, A. J. (2018) · Burns · doi:10.1016/j.burns.2018.09.026 · Cited by 53
qF-SSOP: real-time optical property corrected fluorescence imaging
Valdes, P. A., Angelo, J. P., Choi, H. S., & Gioux, S. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.003597 · Cited by 53 · cited 5×
“Valdes et al. 75 recently applied the principles of real-time optical properties imaging (SSOP) to the quantitative measurement of fluorescence (termed qF-SSOP), allowing to predict fluorescence concentration within 5% in various turbid media optical properties, and in real time, making it amenable…”
BackgroundMethodInfluentialSelf-citationHu, D., Fu, X., He, X., & Ying, Y. B. (2016) · Scientific Reports · doi:10.1038/srep37920 · Cited by 53 · cited 1×
“133,134 This makes SFDI a versatile tool that can be customized by a number of research groups.”
BackgroundSaager, R. B., Quach, A., Rowland, R. A., Baldado, M. L., & Durkin, A. J. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.067001 · Cited by 51
Yang, B., Lesicko, J., Sharma, M., Hill, M. R. S., Sacks, M. S., & Tunnell, J. W. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001520 · Cited by 49 · cited 1×
“The second one analyzes the polarization at several angles from an SFDI measurement.(21,22) The polarization dependence of scattering will indicate the dominant fibers orientation as demonstrated onto collagen-rich samples such as tendons.”
BackgroundYafi, A., Muakkassa, F., Pasupneti, T., Fulton, J., Cuccia, D. J., Mazhar, A., Blasiole, K. N., & Mostow, E. N. (2017) · Lasers in Surgery and Medicine · doi:10.1002/lsm.22692 · Cited by 48 · cited 1×
“93 The majority of these applications require consistent imaging in order to prevent complications.”
BackgroundSelf-citationNandy, S., Mostafa, A., Kumavor, P. D., Sanders, M. M., BREWER, M. A., & Zhu, Q. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.10.101402 · Cited by 47
Saager, R. B., Cuccia, D. J., Saggese, S. J., Kelly, K. M., & Durkin, A. J. (2013) · Lasers in Surgery and Medicine · doi:10.1002/lsm.22139 · Cited by 44 · cited 2×
“15,19 Skin characterization using SFDI has also been used to quantify different layers of skin to gain insight into the structure.”
MethodSelf-citationNear-instant noninvasive optical imaging of tissue perfusion for vascular assessment
Weinkauf, C., Mazhar, A., Vaishnav, K., Hamadani, A. A., Cuccia, D. J., & Armstrong, D. G. (2019) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2018.06.202 · Cited by 43 · cited 1×
“Of note, this study measured an elevated oxygen saturation in diabetes population, likely due to poor oxygen extraction caused by arteriovenous shunting in the skin.(91) This effect was combined with compartment changes in hemoglobin distribution suggesting that it is important to track both hemoglobin oxygenation and…”
BackgroundSelf-citationVisible spatial frequency domain imaging with a digital light microprojector
Lin, A. J., Ponticorvo, A., Konecky, S. D., Cui, H., Rice, T. B., Choi, B., Durkin, A. J., & Tromberg, B. J. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.9.096007 · Cited by 43
Sources of errors in spatial frequency domain imaging of scattering media
Bodenschatz, N., Brandes, A. R., Liemert, A., & Kienle, A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071405 · Cited by 43 · cited 1×
“Recent publications reviewed some of the potential sources of errors in SFDI, and we will attempt here to broaden this previous work by reviewing important considerations required for a proper measurement.(38,39) The first category of errors can be attributed to assumptions made when using models of light propagation.”
BackgroundA Multimodal Assessment of Melanin and Melanocyte Activity in Abnormally Pigmented Hypertrophic Scar
Travis, T. E., Ghassemi, P., Ramella‐Roman, J. C., Prindeze, N. J., Paul, D. W., Moffatt, L. T., Jordan, M. H., & Shupp, J. W. (2014) · Journal of Burn Care & Research · doi:10.1097/bcr.0000000000000154 · Cited by 42 · cited 1×
“98 The most unique finding thus far is the correlation of SFDI scattering changes to gold standard measurements of burn depth with histology (H&E, Masson ’ s trichrome, and Vimentin immunostain).”
BackgroundOptical imaging in an Alzheimer’s mouse model reveals amyloid-β-dependent vascular impairment
Lin, A. J., Liu, G., Castello, N. A., Yeh, J. J., Rahimian, R., Lee, G., Tsay, V., Durkin, A. J., Choi, B., LaFerla, F. M., et al. (2014) · Neurophotonics · doi:10.1117/1.nph.1.1.011005 · Cited by 41 · cited 1×
“117,125 Lin et al. 126 – 128 have also done work to characterize SFDI optical signatures in degenerative diseases like Alzheimer ’ s and characterized base-line properties while measuring vascular impairment due to neuronal death and amyloid-beta plaques.”
Wilson, R. H., Crouzet, C., Torabzadeh, M., Bazrafkan, A. K., Hosseini-Farahabadi, M., Jamasian, B., Donga, D., Alcocer, J., Zaher, S. M., Choi, B., et al. (2017) · Neurophotonics · doi:10.1117/1.nph.4.4.045008 · Cited by 41 · cited 1×
“Other approaches have focused on multiplexed data collection on the detector side by introducing advanced camera hardware to simultaneously capture spectral content.(90)”
BackgroundSingh‐Moon, R. P., Roblyer, D. M., Bigio, I. J., & Joshi, S. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.9.096003 · Cited by 41 · cited 1×
“These efforts including follow-up of drug delivery in the brain tumors in rats, 115 and the monitoring of chemotherapy treatment in mice.”
BackgroundQuantitative 3D imaging of scattering media using structured illumination and computed tomography
Kristensson, E., Berrocal, E., & Aldén, M. (2012) · Optics Express · doi:10.1364/oe.20.014437 · Cited by 40
Nadeau, K. P., Rice, T. B., Durkin, A. J., & Tromberg, B. J. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.11.116005 · Cited by 38 · cited 1×
“An extension of this approach, termed multifrequency synthesis, has also been proposed by the same group using square waves and a Fourier transform to separate contributions to multiple spatial frequencies contained in a particular periodic, nonsinusoidal illumination.(31) Although this approach has the merit to allow…”
MethodQuantitative short-wave infrared multispectral imaging of in vivo tissue optical properties
Wilson, R. H., Nadeau, K. P., Jaworski, F. B., Rowland, R., Nguyen, J. Q., Crouzet, C., Saager, R. B., Choi, B., Tromberg, B. J., & Durkin, A. J. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.8.086011 · Cited by 37 · cited 1×
“Imaging in the SWIR (1000 to 2500 nm) regime has recently gained strong interest owing to high penetration depth, high optical resolution, and the capacity to better measure endogenous constituents such as water and lipids.(86) In this particular implementation, indium gallium arsenide (InGaAs) detectors are used for…”
BackgroundSibai, M., Veilleux, I., Elliott, J. T., Leblond, F., & Wilson, B. C. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.004923 · Cited by 37 · cited 2×
“One of the main applications for this is PpIX fluorescence guided resection in both glioma models and nonmelanoma cancers.(23,25,73,108) Recent work by Valdes et al.”
BackgroundMethodIn vivo spatial frequency domain spectroscopy of two layer media
Yudovsky, D., Nguyen, J. Q., & Durkin, A. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.10.107006 · Cited by 34
Optical sampling depth in the spatial frequency domain.
Hayakawa, C. K., Karrobi, K., Pera, V., Roblyer, D. M., & Venugopalan, V. (2018) · eScholarship (California Digital Library) · Cited by 34
Attenuation-corrected fluorescence extraction for image-guided surgery in spatial frequency domain
Yang, B., Sharma, M., & Tunnell, J. W. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.8.080503 · Cited by 33 · cited 1×
“Early work demonstrated the benefit of optical sectioning in fluorescence using SFDI in turbid systems 68,69 and was recently extended to in vivo imaging.”
BackgroundHigh-speed spatial frequency domain imaging with temporally modulated light
Applegate, M. B., & Roblyer, D. M. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.7.076019 · Cited by 32 · cited 1×
“87,88 In this method depicted in Fig.”
A polarized multispectral imaging system for quantitative assessment of hypertrophic scars
Ghassemi, P., Travis, T. E., Moffatt, L. T., Shupp, J. W., & Ramella‐Roman, J. C. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003337 · Cited by 31 · cited 1×
“The second one analyzes the polarization at several angles from an SFDI measurement.(21,22) The polarization dependence of scattering will indicate the dominant fibers orientation as demonstrated onto collagen-rich samples such as tendons.”
BackgroundSaager, R. B., Dang, A. N., Huang, S. S., Kelly, K. M., & Durkin, A. J. (2017) · Review of Scientific Instruments · doi:10.1063/1.5001075 · Cited by 29 · cited 1×
“The need to better quantify skin properties lead to the development of spatial frequency domain spectroscopy (SFDS) to get highresolution spectra.(121) Saager et al.”
BackgroundNadeau, K. P., Ponticorvo, A., Lee, H., Lu, D., Durkin, A. J., & Tromberg, B. J. (2013) · Optics Letters · doi:10.1364/ol.38.003566 · Cited by 27
In vivo optical signatures of neuronal death in a mouse model of Alzheimer's disease
Lin, A. J., Castello, N. A., Lee, G., Green, K. N., Durkin, A. J., Choi, B., LaFerla, F. M., & Tromberg, B. J. (2013) · Lasers in Surgery and Medicine · doi:10.1002/lsm.22206 · Cited by 25
Wide‐field spatial mapping of in vivo tattoo skin optical properties using modulated imaging
Ayers, F. R., Cuccia, D. J., Kelly, K. M., & Durkin, A. J. (2009) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20782 · Cited by 25 · cited 1×
“120 Another example is the imaging of absorption and scattering properties of skin for the diagnosis of nonmelanoma cancer.”
BackgroundSelf-citationSolid tissue simulating phantoms having absorption at 970 nm for diffuse optics
Kennedy, G. T., Lentsch, G. R., Trieu, B., Ponticorvo, A., Saager, R. B., & Durkin, A. J. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.7.076013 · Cited by 23 · cited 1×
“Multiple groups have depended on SFDI as a tool to characterize calibration phantoms and validate new fabrication methods.(130,131) Konecky et al.”
MethodStructured illumination diffuse optical tomography for noninvasive functional neuroimaging in mice
Reisman, M. D., Markow, Z. E., Bauer, A. Q., & Culver, J. P. (2017) · Neurophotonics · doi:10.1117/1.nph.4.2.021102 · Cited by 21 · cited 1×
“SFDI also has the unique ability to provide the additional depth section capability for tomographic localization of hemodynamic signals during functional activation imaging.(117,125) Lin et al.”
BackgroundSaidian, M., Lakey, J. R. T., Ponticorvo, A., Rowland, R. A., Baldado, M. L., Williams, J. N., Pronda, M., Alexander, M., Flores, A., Li, S., et al. (2018) · International Wound Journal · doi:10.1111/iwj.13005 · Cited by 20 · cited 1×
“92 Clinically, another feasibility study has used SFDI for staging decubitus ulcers.”
BackgroundEffects of motion on optical properties in the spatial frequency domain
Nguyen, J. Q., Saager, R. B., Durkin, A. J., Cuccia, D. J., Kelly, K. M., Jakowatz, J., & Hsiang, D. J. B. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3662454 · Cited by 18 · cited 1×
“These systems are a combination of benchtop imaging systems with some being transportable to preclinical or clinical sites, as well as improved methods for robust measurement during clinical conditions [motion correction and three-dimensional (3-D) correction].(26,27) 2.”
MethodSelf-citationHyperspectral optical tomography of intrinsic signals in the rat cortex
Konecky, S. D., Wilson, R. H., Hagen, N. A., Mazhar, A., Tkaczyk, T., Frostig, R. D., & Tromberg, B. J. (2015) · Neurophotonics · doi:10.1117/1.nph.2.4.045003 · Cited by 18 · cited 1×
“SFDI also has the unique ability to provide the additional depth section capability for tomographic localization of hemodynamic signals during functional activation imaging.(117,125) Lin et al.”
BackgroundSelf-citationSun, J. J., Miller, J. P., Hathi, D., Zhou, H., Achilefu, S., Shokeen, M., & Akers, W. J. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.8.080502 · Cited by 18 · cited 1×
“Early work demonstrated the benefit of optical sectioning in fluorescence using SFDI in turbid systems(68,69) and was recently extended to in vivo imaging.(70) The simple method allows users to preferentially select either long or short pathlengths by varying the spatial frequency of the projection.”
MethodFeasibility of using spatial frequency-domain imaging intraoperatively during tumor resection
Wirth, D. J., Sibai, M., Olson, J. D., Wilson, B. C., Roberts, D. W., & Paulsen, K. D. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.7.071608 · Cited by 14 · cited 1×
“One of the main applications for this is PpIX fluorescence guided resection in both glioma models and nonmelanoma cancers.(23,25,73,108) Recent work by Valdes et al.”
MethodQuantitative subsurface spatial frequency‐domain fluorescence imaging for enhanced glioma resection
Sibai, M., Wirth, D. J., Leblond, F., Roberts, D. W., Paulsen, K. D., & Wilson, B. C. (2018) · Journal of Biophotonics · doi:10.1002/jbio.201800271 · Cited by 11 · cited 1×
“23,73,74 This concept in principle allows quantitative fluorescence, at a subsurface level, to be performed rapidly.”
BackgroundShaul, O., Fanrazi-Kahana, M., Meitav, O., Pinhasi, G. A., & Abookasis, D. (2017) · Applied Optics · doi:10.1364/ao.56.008880 · Cited by 6 · cited 1×
“123 SFDI of the brain is primarily used to provide insight into the neuro-plasticity of the brain for diagnosis and treatment of functional brain episodes that include ischemic strokes, 48 epilepsy, traumatic brain injury, 124 cardiac arrest, 90 and migraines.”
MethodTettelbach (2019) · International Wound Journal · doi:10.1111/iwj.2019.16.issue-1 · Cited by 4
Cited by
Ortega, S., Halicek, M., Fabelo, H., Callico, G. M., & Fei, B. (2020) · Biomedical Optics Express · doi:10.1364/boe.386338 · Cited by 170
“Additionally, Spatial Frequency Domain Imaging (SFDI) make use of modulated light sources and light transport models to extract information about absorption and scattering about different tissues, which can be subsequently used for diagnosis [9].”
MethodSetchfield, K., Gorman, A., Simpson, A. H. R. W., Somekh, M. G., & Wright, A. J. (2023) · Biomedical Optics Express · doi:10.1364/boe.493588 · Cited by 49
Metadata
- Authors
- Gioux, S., Mazhar, A., & Cuccia, D. J.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2019-06-20
- Volume
- 24
- Issue
- 07
- Pages
- 1
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2952818417
- Cited by
- 158
- References
- 76
- FWCI
- 11.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.