Modeling and parameter retrieving in time domain spectroscopy of material and metamaterial
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In this proceeding, we present a software Fit@TDS that enables to retrieve the refractive index of a sample from a timedomain spectroscopy experiment. The software include commonly used methods where the refractive index is extracted from frequency domain data. This method has limitations when the signal is too noisy or when the absorption peak saturates the absorption. Thus, the software includes as well a new method where the refractive index are directly fitted using a model (the Drude-Lorentz for example) in the time domain. This method uses an optimization algorithm that retrieves the parameters of the model corresponding to the studied material. In this proceeding, we explain the methods and test them on fictitious samples to probe the feasibility and reliability of the proposed model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A reliable method for extraction of material parameters in terahertz time-domain spectroscopy
Duvillaret, L., Garet, F., & Coutaz, J.-L. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.571775 · Cited by 994 · cited 1×
“For material analysis, the usual way to retrieve material parameters is to perform the Fourier transform of recorded pulses without and with a sample (respectively, Eref(t) and Es(t) are the time signal and ?̃?ref(ω) 1 and ?̃?s(ω) - their Fourier transforms, the index s is standing for “sample”) the ratio between thes…”
MethodpyOpt: a Python-based object-oriented framework for nonlinear constrained optimization
Perez, R. E., Jansen, P. W., & Martins, J. R. R. A. (2012) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-011-0666-3 · Cited by 426
Far infrared spectroscopy with subpicosecond electrical pulses on transmission lines
Sprik, R., Duling, I. N., Chi, C.-C., & Grischkowsky, D. (1987) · Applied Physics Letters · doi:10.1063/1.98395 · Cited by 42
Ahmed, O. S., Swillam, M. A., Bakr, M. H., & Li, X. (2010) · Journal of Lightwave Technology · doi:10.1109/jlt.2010.2047936 · Cited by 36 · cited 2×
“For this purpose, the function describing the refractive index versus frequency is fit using models such as the Drude-Lorentz one [5, 8].”
BackgroundMethodBernier, M., Garet, F., Coutaz, J.-L., Minamide, H., & Sato, A. (2016) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2016.2535244 · Cited by 29 · cited 1×
“Indeed, a low signal to noise ratio of the data or a strong absorption in the sample will lead to difficulties in getting refractive index following the Kramers-Kronig relations [7].”
BackgroundInfluentialLinewidth Extraction From the THz Absorption Spectra Using a Modified Lorentz Model
Li, Z., Zhang, Z., Zhao, X., Su, H., Zhang, H., & Lan, J. (2013) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-013-0007-2 · Cited by 10 · cited 1×
“For this purpose, the function describing the refractive index versus frequency is fit using models such as the Drude-Lorentz one [5, 8].”
Method
Cited by
THz-TDS Time-Trace Analysis for the Extraction of Material and Metamaterial Parameters
Peretti, R., Mitryukovskiy, S., Froberger, K., Mebarki, M. A., Eliet, S., Vanwolleghem, M., & Lampin, J.-F. (2019) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2018.2889227 · Cited by 78
Self-citationBeyond the "Dynamic range" approach In noise evaluation for Terahertz Time domain spectrometers
Muller, C., Lavancier, M., Bichon, J., Hannotte, T., Lampin, J.-F., Eliet, S., & Peretti, R. (2021) · 2021 46th International Conference on Infrared, Millimeter and Terahertz Waves (IRMMW-THz) · doi:10.1109/irmmw-thz50926.2021.9566941 · Cited by 7
Self-citationRetrieving material and metamaterial parameters directly from time-domain spectroscopy time trace
Peretti, R., Mitryukovskiy, S., Kevin, F., & Lampin, J.-F. (2018) · 2018 43rd International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz) · doi:10.1109/irmmw-thz.2018.8510300 · Cited by 7
Self-citationTerahertz time domain spectroscopy data processing: analysing uncertainties to push boundaries
Lavancier, M., Eliet Barois, S., Denakpo, E., Vlieghe, J., Vindas, N., Hindle, F., Cuisset, A., & Peretti, R. (2022) · Terahertz Photonics II · doi:10.1117/12.2620069 · Cited by 2
Self-citationSuper resolution of a 400 MHz rotational line doublet with a TDS using a 850 ps long delay line
Eliet, S., Cuisset, A., Hindle, F., Lampin, J.-F., & Peretti, R. (2021) · 2021 46th International Conference on Infrared, Millimeter and Terahertz Waves (IRMMW-THz) · doi:10.1109/irmmw-thz50926.2021.9566817 · Cited by 2
Self-citation
Metadata
- Authors
- Micica, M., Mitryukovskiy, S. I., Froberger, K., Peretti, R., Eliet, S., Vanwolleghem, M., & Lampin, J.-F.
- Venue
- Nonlinear Optics and its Applications 2018
- Publisher
- SPIE
- Published
- 2018-05-14
- Pages
- 25
- OpenAlex
- W2803864324
- Cited by
- 10
- References
- 6
- FWCI
- 7.46
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modeling and parameter retrieving in time domain spectroscopy of material and metamaterial. https://app.cochat.ai/papers/10.1117/12.2306932
- The paper
- Micica, M., Mitryukovskiy, S. I., Froberger, K., Peretti, R., Eliet, S., Vanwolleghem, M., & Lampin, J.-F. (2018). Modeling and parameter retrieving in time domain spectroscopy of material and metamaterial. Nonlinear Optics and its Applications 2018. https://doi.org/10.1117/12.2306932
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.