Accurate Characterization of Resonant Samples in the Terahertz Regime Through a Technique Combining Time-Domain Spectroscopy and Kramers–Kronig Analysis
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
We propose and experimentally demonstrate an original method, combining terahertz time-domain spectroscopy (THz-TDS) and Kramers-Kronig relations (KKR), in order to characterize in transmission materials exhibiting high absorption peaks. At these frequencies, the modulus of transmittance of a sample could be null, or at least smaller than the detector noise, and consequently the signal phase is lost, not only at the peak frequency, but also at higher frequencies. Thus, for these high frequencies, the value of the refractive index estimated from the measured THz-TDS data could be strongly erroneous. Using an optimized version of KKR, namely singly subtractive KKR, we are able to retrieve the phase of the THz transmittance over the whole studied bandwidth and thus to correct the THz-TDS data to precisely determine the refractive index as well as the absorption coefficient of the material over almost the whole THz range.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition to complicated phase unwrapping, and to losing the phase for strong absorption [26], this produces artifact-noises that can degrade the quality of the measurement and yield misleading results.”
From A New Metric for the Comparison of Permittivity Models in Terahertz Time-Domain Spectroscopy (2024) · cites this paper as [26]
In the citing paper
“In addition, a low dynamic range of the measured data, or a strong absorption in the sample, leads to difficulties in obtaining the refractive index following the Kramers-Kroenig relations.”
From THz-TDS Time-Trace Analysis for the Extraction of Material and Metamaterial Parameters (2019) · cites this paper as [23]
In the citing paper
“Evidently, the phase is lost in the frequency domain and thus the algorithm is not able to unwrap it properly [23].”
From THz-TDS Time-Trace Analysis for the Extraction of Material and Metamaterial Parameters (2019) · cites this paper as [23]
In the citing paper
“( iv ) Since we are fitting in the time domain, the phase is not lost in the presence of strong absorption, and an additional step is not needed [23], as shown with our experiments on lactose.”
From THz-TDS Time-Trace Analysis for the Extraction of Material and Metamaterial Parameters (2019) · cites this paper as [23]
In the citing paper
“This method in the frequency domain reach its limitations for instance when the signal is too noisy due to a too strong absorption [25].”
From Signal Estimation and Uncertainties Extraction in Terahertz Time-Domain Spectroscopy (2025) · cites this paper as [25]
Citations
Cites
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239 · cited 1×
“T IME-DOMAIN spectroscopy (TDS) techniques have been used for more than 20 years for characterizing materials in the terahertz (THz) range [1].”
MethodCausality and the Dispersion Relation: Logical Foundations
Toll, J. S. (1956) · Physical Review · doi:10.1103/physrev.104.1760 · Cited by 1,083 · cited 1×
“On the other hand, as causality induces a dependence between imaginary and real parts of the complex refractive index [5], Kramers–Kronig relations (KKR) are commonly used in spectroscopy to calculate the refractive index of a material from its measured transmittance.”
MethodA reliable method for extraction of material parameters in terahertz time-domain spectroscopy
Duvillaret, L., Garet, F., & Coutaz, J.-L. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.571775 · Cited by 994 · cited 3×
“Once this phase is corrected, we apply a classical THz-TDS extraction [2] using the corrected value of .”
BackgroundMethodInfluentialSelf-citationKramers-Kronig Relations in Optical Materials Research
(2005) · Springer Series in Optical Sciences · doi:10.1007/b138913 · Cited by 555
THz reflection spectroscopy of liquid water
Thrane, L., Jacobsen, R. H., Uhd Jepsen, P., & Keiding, S. R. (1995) · Chemical Physics Letters · doi:10.1016/0009-2614(95)00543-d · Cited by 339 · cited 1×
“A solution to this problem is to perform reflection THz-TDS [4].”
MethodCausality-imposed (Kramers-Kronig) relationships between attenuation and dispersion
Waters, K. R., Mobley, J., & Miller, J. G. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1503968 · Cited by 187 · cited 1×
“Even though numerical solutions [6], [7] exist to overcome this experimental limit, the extraction process based on Kramers–Kronig transform (KKT) still depends on the available bandwidth, and the accuracy of the calculated refractive index is limited by the unknown coefficient of absorption localized outside the expe…”
MethodUncertainty in terahertz time-domain spectroscopy measurement
Withayachumnankul, W., Fischer, B. M., Lin, H., & Abbott, D. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.001059 · Cited by 181 · cited 1×
“This simulation work permits to validate expressions (8), (13), and (22), and to weight the different error contributions for a realistic study case, while systematic errors [15], [16] that are encountered in experiments such as sample position and thickness or THz beam shape do not perturb the numerical analysis.”
MethodDuvillaret, L., Garet, F., Roux, J.-F., & Coutaz, J.-L. (2001) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.974233 · Cited by 163 · cited 1×
“We multiply this transmission by the incoming THz beam spectrum delivered by a photo-conducting antenna, and then we calculate the signal given by a photoconducting receiver, using the THz antenna model given in [14].”
MethodSelf-citationInfluence of noise on the characterization of materials by terahertz time-domain spectroscopy
Duvillaret, L., Garet, F., & Coutaz, J.-L. (2000) · Journal of the Optical Society of America B · doi:10.1364/josab.17.000452 · Cited by 151 · cited 3×
“Therefore, following reference [13] and considering expression (3), the intrinsic error made on the calculated refractive index is given by”
BackgroundMethodSelf-citationFar-infrared properties of DAST
Walther, M., Jensby, K., Keiding, S. R., Takahashi, H., & Ito, H. (2000) · Optics Letters · doi:10.1364/ol.25.000911 · Cited by 113 · cited 1×
“1 and 3 THz [12], due to the vibration of the anions and cations within the molecule.”
Background
Cited by
Smolyanskaya, O. A., Chernomyrdin, N. V., Konovko, A. A., Zaytsev, K. I., Ozheredov, I. A., Cherkasova, O. P., Nazarov, M. M., Guillet, J.-P., Kozlov, S. A., Kistenev, Y. V., et al. (2018) · Progress in Quantum Electronics · doi:10.1016/j.pquantelec.2018.10.001 · Cited by 292
Self-citationThe progress and perspectives of terahertz technology for diagnosis of neoplasms: a review
Zaytsev, K. I., Dolganova, I. N., Chernomyrdin, N. V., Katyba, G. M., Gavdush, A. A., Cherkasova, O. P., Komandin, G. A., Shchedrina, M. A., Khodan, A. N., Ponomarev, D. S., et al. (2020) · Journal of Optics · doi:10.1088/2040-8986/ab4dc3 · Cited by 205
“Thus, in transmission mode measurements, one should use sliced thin samples with parallel sides and a thickness of <100 μm [161].”
BackgroundTHz-TDS Time-Trace Analysis for the Extraction of Material and Metamaterial Parameters
Peretti, R., Mitryukovskiy, S., Froberger, K., Mebarki, M. A., Eliet, S., Vanwolleghem, M., & Lampin, J.-F. (2019) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2018.2889227 · Cited by 78
“are fitting in the time domain, the phase is not lost in the presence of strong absorption, and an additional step is not needed [23], as shown with our experiments on lactose.”
BackgroundMethodInfluentialDiagnosis of Glioma Molecular Markers by Terahertz Technologies
Черкасова, О. П., Peng, Y., Konnikova, M. R., Kistenev, Y. V., Shi, C., Vrazhnov, D. A., Shevelev, O. B., Zavjalov, E. L., Kuznetsov, S. A., & Shkurinov, A. P. (2021) · Photonics · doi:10.3390/photonics8010022 · Cited by 41
Terahertz conductivity of two-dimensional materials: a review
Mitra, S., Avazpour, L., & Knežević, I. (2025) · Journal of Physics Condensed Matter · doi:10.1088/1361-648x/adab6a · Cited by 20
Metadata
- Authors
- Bernier, M., Garet, F., Coutaz, J.-L., Minamide, H., & Sato, A.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- RIKEN (JP)
- Venue
- IEEE Transactions on Terahertz Science and Technology
- Published
- 2016-05
- Volume
- 6
- Issue
- 3
- Pages
- 442-450
- ISSN
- 2156-342X (ISSN-L)
- 2156-3446
- OpenAlex
- W2317929516
- Semantic Scholar
- aa2af17815bfbcefcaf6097dc54f2ee24a449186
- Cited by
- 29
- References
- 21
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 4 · 2020: 2 · 2019: 2 · 2018: 7 · 2017: 2
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Terahertz Science and Technology (publishedVersion)
- HAL (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Metamaterials and Metasurfaces Applications
- Keywords
- terahertz time-domain spectroscopy, Kramers-Kronig relations, refractive index retrieval, absorption coefficient
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accurate Characterization of Resonant Samples in the Terahertz Regime Through a Technique Combining Time-Domain Spectroscopy and Kramers–Kronig Analysis. https://app.cochat.ai/papers/10.1109/tthz.2016.2535244
- The paper
- Bernier, M., Garet, F., Coutaz, J.-L., Minamide, H., & Sato, A. (2016). Accurate Characterization of Resonant Samples in the Terahertz Regime Through a Technique Combining Time-Domain Spectroscopy and Kramers–Kronig Analysis. IEEE Transactions on Terahertz Science and Technology. https://doi.org/10.1109/tthz.2016.2535244
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.