Comparison of two methods of measuring forearm oxygen consumption (VO2) by near infrared spectroscopy
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Near infrared spectroscopy (NIRS) was used to measure oxygen consumption (V ˙ O2) in the human forearm with two different methods.V ˙ O2 was measured in ten patients, first by inducing a forearm venous occlusion and then an ischemia. The mean value ofV ˙ O2 was 3.3 6 1.1 mMO2 3 100 g−13min−1 during venous occlusion and 2.960.9 mMO2 3 100 g−13min−1 during ischemia. The difference between the two means was 0.4 mMO2 3 100 g−13min−1. A good agreement between the two methods was demonstrated. The results showed that NIRS is a useful tool for the measurement of V ˙ O2 . The venous occlusion method was the method of choice because it could be easily repeated at the bedside without causing any discomfort to the patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Homma, S., Fukunaga, T., & Kagaya, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.252417 · Cited by 123 · cited 1×
“8 cm were avoided, the near-infrared light is estimated to have penetrated the muscle tissue at least deep enough to reach half the distance between the light source and the detector.(20)”
Background
Cited by
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Self-citationUnderstanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Van Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430
Ryan, T. E., Erickson, M. L., Brizendine, J. T., Young, H.-J., & McCully, K. K. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00319.2012 · Cited by 233
Jones, S., Chiesa, S. T., Chaturvedi, N., & Hughes, A. D. (2016) · Artery Research · doi:10.1016/j.artres.2016.09.001 · Cited by 184
Metadata
- Authors
- De Blasi, R. A.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 1997
- Volume
- 2
- Issue
- 2
- Pages
- 171
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2078340693
- Cited by
- 50
- References
- 5
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of two methods of measuring forearm oxygen consumption (VO2) by near infrared spectroscopy. https://app.cochat.ai/papers/10.1117/12.269893
- The paper
- De Blasi, R. A. (1997). Comparison of two methods of measuring forearm oxygen consumption (VO2) by near infrared spectroscopy. Journal of Biomedical Optics. https://doi.org/10.1117/12.269893
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.