Data analysis methods for near-infrared spectroscopy of tissue: problems in determining the relative cytochrome aa<formula>3</formula> concentration:
The DOI matches its Crossref record.
Abstract
In the brain of the adult rat, the ratio of the absorption coefficient of hemoglobin to that of the cytochromes is approximately ten and in the newborn rat brain the ratio is even higher. Additionally the absorption spectra of these compounds overlap markedly. Under these circumstances the accurate determination of cytochrome concentration is difficult. There are many possible sources of error: (i) Non linear measuring equipment. (ii) Inaccurate hemoglobin and cytochrome spectra. (iii) A wavelength dependent effective optical pathlength. (iv) An absorption coefficient dependent effective optical pathlength. (v) Oxygenation dependent changes in tissue scattering. The first two sources of error can be solved with careful instrumental and experimental design. The last three are much more problematic, but can be addressed using time resolved measurements. These are the topic of this paper. A wavelength dependence of the optical pathlength leads to a distortion of the optical spectra of the chromophores in brain tissue. A simple method of examining the wavelength dependant effects is discussed. The selection of the correct wavelength range is important in minimizing these problems. Until recently, all near infrared data processing 'algorithms' have assumed a linear Beer Lambert relationship between the measured attenuation spectra and tissue absorption coefficient. However, picosecond optical techniques have shown that at a single wavelength, the optical pathlength in the rat brain can vary by 10% implying that the Beer Lambert law is not strictly valid. A non linear correction of tissue spectra which can be based on results from time of flight measurements is described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Non-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Quantification in tissue near–infrared spectroscopy
Delpy, D. T., & Cope, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0046 · Cited by 507
Self-citationMatcher, S. J., Cope, M., & Delpy, D. T. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/1/011 · Cited by 323
Self-citationFantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
Jones, M., Berwick, J., Johnston, D., & Mayhew, J. (2001) · NeuroImage · doi:10.1006/nimg.2001.0808 · Cited by 239
“A technical problem associated with spectroscopic analysis of in vivo data arises from the effects of tissue scattering and a weakness of many algorithms is the failure to deal adequately with the nonlinearities introduced by the variation of optical path length with wavelength (Cope et al., 1991; Matcher et al., 1995…”
MethodInfluentialFantini, S., Franceschini, M. A., & Gratton, E. (1994) · Journal of the Optical Society of America B · doi:10.1364/josab.11.002128 · Cited by 228
Near-Infrared spectroscopy: Theory and applications
Wahr, J. A., Tremper, K. K., Samra, S., & Delpy, D. T. (1996) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(96)80107-8 · Cited by 227
Self-citationSpectral dependence of temporal point spread functions in human tissues
Essenpreis, M., Elwell, C. E., Cope, M., van der Zee, P., Arridge, S. R., & Delpy, D. T. (1993) · Applied Optics · doi:10.1364/ao.32.000418 · Cited by 195
Self-citationFrequency-domain optical absorption spectroscopy of finite tissue volumes using diffusion theory
Pogue, B. W., & Patterson, M. S. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/7/008 · Cited by 184
Franceschini, M. A., Fantini, S., Paunescu, L. A., Maier, J. S., & Gratton, E. (1998) · Applied Optics · doi:10.1364/ao.37.007447 · Cited by 172
Bale, G., Elwell, C. E., & Tachtsidis, I. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091307 · Cited by 169
“It ignores, however, the multiple scattering effects including the nonlinear relationship between absorption and attenuation; 43 this is discussed further in the Sec.”
Determination of optical properties and blood oxygenation in tissue using continuous NIR light
Liu, H., Boas, D. A., Zhang, Y., Yodh, A. G., & Chance, B. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/11/015 · Cited by 167
Measurement of cytochrome oxidase and mitochondrial energetics by near–infrared spectroscopy
Cooper, C. E., & Springett, R. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0048 · Cited by 160
“A derivation of the UCL algorithm that can theoretically correct for variations in the latter property has also been published (Cope et al. 1991).”
Background
Metadata
- Authors
- Cope, M., van der Zee, P., Essenpreis, M., Arridge, S. R., & Delpy, D. T.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 1991-05-01
- Volume
- 1431
- Pages
- 251-262
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2061987937
- Cited by
- 76
- References
- 0
- FWCI
- 14.51
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.