Active motion artifact cancellation for wearable health monitoring sensors using collocated MEMS accelerometers
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper presents an active noise cancellation technique for recovering wearable biosensor signals corrupted by bodily motion. A finger mounted photoplethysmograph (PPG) ring sensor with a collocated MEMS accelerometer is considered. The system by which finger acceleration disturbs PPG output is identified and a means of modeling this relationship is prescribed using either FIR or Laguerre models. This means of modeling motivates the use of a recursive least squares active noise cancellation technique using the MEMS accelerometer reading as an input for a FIR or Laguerre model. The model parameters are identified and tuned in real time to minimize the power of the recovered PPG signal. Experiments show that the active noise cancellation method can recover pulse information from PPG signals corrupted with up to 2G of acceleration with 85% improvement in mean squared error.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 1×
“This will yield a parameter vector θˆ whose length is the filter order such that the estimated disturbance is ( ) ( ) θ ϕ ˆ ˆ T w = t t ( 6 )”
BackgroundArtifact-resistant power-efficient design of finger-ring plethysmographic sensors
Rhee, S., Yang, B.-H., & Asada, H. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930904 · Cited by 235
Self-citation
Cited by
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“Figure 5 shows a motion-tolerant wearable biosensor using a MEMS accelerometer [52,53], which operates based on adaptive noise cancellation utilizing an acceleration reference.”
MethodA 30 $\mu$W Analog Signal Processor ASIC for Portable Biopotential Signal Monitoring
Yazicioglu, R. F., Kim, S., Torfs, T., Kim, H., & Van Hoof, C. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2085930 · Cited by 263
Current progress of photoplethysmography and SPO2 for health monitoring
Tamura, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 247
A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49
Reducing motion artifacts in photoplethysmograms by using relative sensor motion: Phantom study
Wijshoff, R. W. C. G. R., Mischi, M., Veen, J., & Van Der Lee, A. M. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.11.117007 · Cited by 40
“Accelerometers have been applied as well to obtain a reference for the motion artifacts in a correlation canceler,(22) also combined with the Laguerre expansion.(23) Furthermore, sensor-coupling motion artifacts have been removed by equalizing a transmissive PPG by a second transmissive PPG measured at a different wav…”
Metadata
- Authors
- Gibbs, P. T., Wood, L. B., & Asada, H. H.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2005-05-17
- Volume
- 5765
- Pages
- 811
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2080911522
- Cited by
- 41
- References
- 2
- FWCI
- 1.55
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.