The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
A 30 $\mu$W Analog Signal Processor ASIC for Portable Biopotential Signal Monitoring
Abstract
This paper presents the design and implementation of an analog signal processor (ASP) ASIC for portable ECG monitoring systems. The ASP ASIC performs four major functionalities: 1) ECG signal extraction with high resolution, 2) ECG signal feature extraction, 3) adaptive sampling ADC for the compression of ECG signals, 4) continuous-time electrode-tissue impedance monitoring for signal integrity monitoring. These functionalities enable the development of wireless ECG monitoring systems that have significantly lower power consumption yet that are more capable than their predecessors. The ASP has been implemented in 0.5 μm CMOS process and consumes 30 μW from a 2 V supply. The noise density of the ECG readout channel is 85 nV/√Hz and the CMRR is better that 105 dB. The adaptive sampling ADC is capable of compressing the ECG data by a factor of 7 and the heterodyne chopper readout extracts the features of the ECG signals. Combination of these two features leads to a factor 4 reduction in the power consumption of a wireless ECG monitoring system. Furthermore, the proposed continuous-time impedance monitoring circuit enables the monitoring of the signal integrity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
Verma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 526
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
Estimation of QRS Complex Power Spectra for Design of a QRS Filter
Thakor, N. V., Webster, J. G., & Tompkins, W. J. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325393 · Cited by 427
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.894804 · Cited by 382
Self-citationA 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006462 · Cited by 271
Self-citation
Cited by
Compressed Sensing System Considerations for ECG and EMG Wireless Biosensors
Dixon, A. M. R., Allstot, E. G., Gangopadhyay, D., & Allstot, D. J. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2193668 · Cited by 311
Van Helleputte, N., Konijnenburg, M., Pettine, J., Jee, D.-W., Kim, H., Morgado, A., Van Wegberg, R., Torfs, T., Mohan, R., Breeschoten, A., et al. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2359962 · Cited by 253
Self-citationNeural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
A 1-V 0.25- $\mu \text{W}$ Inverter Stacking Amplifier With 1.07 Noise Efficiency Factor
Shen, L., Lu, N., & Sun, N. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2786724 · Cited by 101
Metadata
- Authors
- Yazicioglu, R. F., Kim, S., Torfs, T., Kim, H., & Van Hoof, C.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2011-01
- Volume
- 46
- Issue
- 1
- Pages
- 209-223
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2054295738
- Cited by
- 263
- References
- 19
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 30 $\mu$W Analog Signal Processor ASIC for Portable Biopotential Signal Monitoring. https://app.cochat.ai/papers/10.1109/jssc.2010.2085930
- The paper
- Yazicioglu, R. F., Kim, S., Torfs, T., Kim, H., & Van Hoof, C. (2011). A 30 $\mu$W Analog Signal Processor ASIC for Portable Biopotential Signal Monitoring. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2010.2085930
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.