The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Human observer detection experiments with mammograms and power‐law noise
Abstract
We determined contrast thresholds for lesion detection as a function of lesion size in both mammograms and filtered noise backgrounds with the same average power spectrum, Experiments were done using hybrid images with digital images of tumors added to digitized normal backgrounds, displayed on a monochrome monitor. Four tumors were extracted from digitized specimen radiographs. The lesion sizes were varied by digital rescaling to cover the range from 0.5 to 16 mm. Amplitudes were varied to determine the value required for 92% correct detection in two‐alternative forced‐choice (2AFC) and 90% for search experiments. Three observers participated, two physicists and a radiologist. The 2AFC mammographic results demonstrated a novel contrast‐detail (CD) diagram with threshold amplitudes that increased steadily (with slope of 0.3) with increasing size for lesions larger than 1 mm. The slopes for prewhitening model observers were about 0.4. Human efficiency relative to these models was as high as 90%. The CD diagram slopes for the 2AFC experiments with filtered noise were 0.44 for humans and 0.5 for models. Human efficiency relative to the ideal observer was about 40%. The difference in efficiencies for the two types of backgrounds indicates that breast structure cannot be considered to be pure random noise for 2AFC experiments. Instead, 2AFC human detection with mammographic backgrounds is limited by a combination of noise and deterministic masking effects. The search experiments also gave thresholds that increased with lesion size. However, there was no difference in human results for mammographic and filtered noise backgrounds, suggesting that breast structure can be considered to be pure random noise for this task. Our conclusion is that, in spite of the fact that mammographic backgrounds have nonstationary statistics, models based on statistical decision theory can still be applied successfully to estimate human performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Table of Integrals, Series, and Products
(1980) · Elsevier eBooks · doi:10.1016/c2013-0-10754-4 · Cited by 18,782
(1966) · Medical Entomology and Zoology · Cited by 10,293
Random Data-Analysis and Measurement Procedures
Bendat, J. S., Piersol, A. G., & Saunders, H. (1989) · Journal of Vibration and Acoustics · doi:10.1115/1.3269865 · Cited by 6,375
Quest: A Bayesian adaptive psychometric method
Watson, A. B., & Pelli, D. G. (1983) · Perception & Psychophysics · doi:10.3758/bf03202828 · Cited by 2,410
Spectral Analysis for Physical Applications
Percival, D. B., & Walden, A. T. (1993) · Cambridge University Press eBooks · doi:10.1017/cbo9780511622762 · Cited by 2,161
Computational Models of Visual Processing
(1991) · The MIT Press eBooks · doi:10.7551/mitpress/2002.001.0001 · Cited by 1,073
Graham, N. V. S. (1989) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195051544.001.0001 · Cited by 946
Visible differences predictor: an algorithm for the assessment of image fidelity
Daly, S. J. (1992) · SPIE Proceedings · doi:10.1117/12.135952 · Cited by 718
A four mechanism model for threshold spatial vision
Wilson, H. R., & Bergen, J. R. (1979) · Vision Research · doi:10.1016/0042-6989(79)90117-2 · Cited by 714
Fractals in nature: From characterization to simulation
Voss, R. F. (1988) · Springer eBooks · doi:10.1007/978-1-4612-3784-6_1 · Cited by 627
Model observers for assessment of image quality.
Barrett, H. H., Yao, J., Rolland, J. P., & Myers, K. J. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.21.9758 · Cited by 531
Signal detection and recognition by human observers : contemporary readings
Swets, J. A. (1964) · Wiley eBooks · Cited by 446
New methods in statistical economics
Mandelbrot, B. B. (1997) · Fractals and Scaling in Finance · doi:10.1007/978-1-4757-2763-0_3 · Cited by 434
Efficiency of Human Visual Signal Discrimination
Burgess, A. E., Wagner, R. F., Jennings, R. J., & Barlow, H. B. (1981) · Science · doi:10.1126/science.7280685 · Cited by 411
Self-citationAddition of a channel mechanism to the ideal-observer model
Myers, K. J., & Barrett, H. H. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.002447 · Cited by 400
Russ, J. C. (1994) · Springer eBooks · doi:10.1007/978-1-4899-2578-7 · Cited by 382
Rosenberg, R. D., Hunt, W. C., Williamson, M. R., Gilliland, F. D., Wiest, P. W., Kelsey, C. A., Key, C. R., & Linver, M. N. (1998) · Radiology · doi:10.1148/radiology.209.2.9807581 · Cited by 364
Spatial arrangement of line, edge and grating detectors revealed by subthreshold summation
Kulikowski, J. J., & King-Smith, P. E. (1973) · Vision Research · doi:10.1016/0042-6989(73)90006-0 · Cited by 296
Visual signal detection IV Observer inconsistency
Burgess, A. E., & Colborne, B. (1988) · Journal of the Optical Society of America A · doi:10.1364/josaa.5.000617 · Cited by 282
Self-citationEffect of random background inhomogeneity on observer detection performance
Rolland, J. P., & Barrett, H. H. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.000649 · Cited by 272
Effect of noise correlation on detectability of disk signals in medical imaging
Myers, K. J., Barrett, H. H., Borgstrom, M. C., Patton, D. D., & Seeley, G. W. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001752 · Cited by 205
Statistically defined backgrounds:performance of a modified nonprewhitening observer model
Burgess, A. E. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.001237 · Cited by 187
Self-citationDetection and Recognition of Simple Spatial Forms
Watson, A. B. (1983) · Springer Series in Information Sciences · doi:10.1007/978-3-642-68888-1_8 · Cited by 171
Visual signal detectability with two noise components: anomalous masking effects
Burgess, A. E., Li, X., & Abbey, C. K. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002420 · Cited by 165
Self-citationThe Influence of Structured Noise on the Detection of Radiologic Abnormalities
Révész, G., Kundel, H. L., & Graber, M. (1974) · Investigative Radiology · doi:10.1097/00004424-197411000-00009 · Cited by 149
Visual signal detection II Signal-location identification
Burgess, A. E., & Ghandeharian, H. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000906 · Cited by 148
Self-citationDigital image processing: effect on detectability of simulated low-contrast radiographic patterns.
Ishida, M., Doi, K., Loo, L. N., Metz, C. E., & Lehr, J. L. (1984) · Radiology · doi:10.1148/radiology.150.2.6691118 · Cited by 134
A Practical Guide to Model Observers for Visual Detection in Synthetic and Natural Noisy Images
Eckstein, M. P., Abbey, C. K., & Bochud, F. O. (2010) · SPIE eBooks · doi:10.1117/3.832716.ch10 · Cited by 67
Bochud, F. O., Abbey, C. K., & Eckstein, M. P. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.000193 · Cited by 62
Signal detection by human observers.
Swets, J. A., & Green, D. M. (1965) · PsycEXTRA Dataset · doi:10.1037/e444572004-001 · Cited by 54
The anatomy of missed breast cancers
Reintgen, D. S., Berman, C. G., Cox, C. E., Baekey, P., Nicosia, S. V., Greenberg, H., Bush, C., Lyman, G. H., & Clark, R. A. (1993) · Surgical Oncology · doi:10.1016/0960-7404(93)90046-2 · Cited by 48
Spatial frequency masking and Weber's Law
Swift, D. J., & Smith, R. A. (1983) · Vision Research · doi:10.1016/0042-6989(83)90124-4 · Cited by 47
Role of knowledge in human visual temporal integration in spatiotemporal noise
Eckstein, M. P., Whiting, J. S., & Thomas, J. P. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.001960 · Cited by 37
Cited by
Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT
Bian, J., Siewerdsen, J. H., Han, X., Sidky, E. Y., Prince, J. L., Pelizzari, C. A., & Pan, X. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/001 · Cited by 373
Andersson, I., Ikeda, D. M., Zackrisson, S., Ruschin, M., Svahn, T., Timberg, P., & Tingberg, A. (2008) · European Radiology · doi:10.1007/s00330-008-1076-9 · Cited by 343
McCollough, C. H., Chen, G. H., Kalender, W., Leng, S., Samei, E., Taguchi, K., Wang, G., Yu, L., & Pettigrew, R. I. (2012) · Radiology · doi:10.1148/radiol.12112265 · Cited by 276
Understanding the Impact of Time Pressure and Automation Support in a Visual Search Task
Rieger, T., & Manzey, D. (2024) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/00187208221111236 · Cited by 40
Metadata
- Authors
- Burgess, A. E., Jacobson, F. L., & Judy, P. F.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2001-04
- Volume
- 28
- Issue
- 4
- Pages
- 419-437
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2067543687
- Cited by
- 453
- References
- 33
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.