Micro‐CT with respiratory and cardiac gating
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Cardiopulmonary imaging in rodents using micro‐computed tomography (CT) is a challenging task due to both cardiac and pulmonary motion and the limited fluence rate available from micro‐focus x‐ray tubes of most commercial systems. Successful imaging in the mouse requires recognition of both the spatial and temporal scales and their impact on the required fluence rate. Smaller voxels require an increase in the total number of photons (integrated fluence) used in the reconstructed image for constant signal‐to‐noise ratio. The faster heart rates require shorter exposures to minimize cardiac motion blur imposing even higher demands on the fluence rate. We describe a system with fixed tube/detector and with a rotating specimen. A large focal spot x‐ray tube capable of producing high fluence rates with short exposure times was used. The geometry is optimized to match focal spot blur with detector pitch and the resolution limits imposed by the reproducibility of gating. Thus, it is possible to achieve isotropic spatial resolution of with a fluence rate at the detector 250 times that of a conventional cone beam micro‐CT system with rotating detector and microfocal x‐ray tube. Motion is minimized for any single projection with exposures that are synchronized to both cardiac and breathing motion. System performance was validated in vivo by studies of the cardiopulmonary structures in C57BL/6 mice, demonstrating the value of motion integration with a bright x‐ray source.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490
Cited by
In vivo small-animal imaging using micro-CT and digital subtraction angiography
Badea, C. T., Drangova, M., Holdsworth, D. W., & Johnson, G. A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/19/r01 · Cited by 264
Self-citationMicro-CT of rodents: State-of-the-art and future perspectives
Clark, D. P., & Badea, C. T. (2014) · Physica Medica · doi:10.1016/j.ejmp.2014.05.011 · Cited by 229
“However, because of the time spent waiting for the coincidence of cardiac and respiratory events, the scan time can take as long as 1 h to cover 10 different phases of the cardiac cycle [4].”
BackgroundSelf-citationQuantitative comparison of direct phase retrieval algorithms in in‐line phase tomography
Langer, M., Cloetens, P., Guigay, J., & Peyrin, F. (2008) · Medical Physics · doi:10.1118/1.2975224 · Cited by 179
In Vivo mouse imaging and spectroscopy in drug discovery
Beckmann, N., Kneuer, R., Gremlich, H., Karmouty‐Quintana, H., Blé, F., & Müller, M. (2007) · NMR in Biomedicine · doi:10.1002/nbm.1153 · Cited by 118
Metadata
- Authors
- Badea, C., Hedlund, L. W., & Johnson, G. A.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2004-11-19
- Volume
- 31
- Issue
- 12
- Pages
- 3324-3329
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W1988514106
- Cited by
- 196
- References
- 1
- FWCI
- 12.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.