2D‐3D registration of coronary angiograms for cardiac procedure planning and guidance
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We present a completely automated 2D‐3D registration technique that accurately maps a patient‐specific heart model, created from preoperative images, to the patient's orientation in the operating room. This mapping is based on the registration of preoperatively acquired 3D vascular data with intraoperatively acquired angiograms. Registration using both single and dual‐plane angiograms is explored using simulated but realistic datasets that were created from clinical images. Heart deformations and cardiac phase mismatches are taken into account in our validation using a digital 4D human heart model. In an ideal situation where the pre‐ and intraoperative images were acquired at identical time points within the cardiac cycle, the single‐plane and the dual‐plane registrations resulted in 3D root‐mean‐square (rms) errors of and , respectively. When a 10% timing offset was added between the pre‐ and the intraoperative acquisitions, the single‐plane registration approach resulted in inaccurate registrations in the out‐of‐plane axis, whereas the dual‐plane registration exhibited a 98% success rate with a 3D rms error of . When all potential sources of error were included, namely, the anatomical background, timing offset, and typical errors in the vascular tree reconstruction, the dual‐plane registration performed at 94% with an accuracy of .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
Cited by
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“This group of methods was referred to as hybrid (Turgeon et al., 2005; Vermandel et al., 2006) because of the combination of segmentation, typical of feature-based methods, and pixel-wise comparison, typical of intensity-based methods.”
BackgroundMethodInfluentialImage-guidance for surgical procedures
Peters, T. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/14/r01 · Cited by 249
Self-citationDeformable 2D-3D Registration of Vascular Structures in a One View Scenario
Groher, M., Zikic, D., & Navab, N. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2011519 · Cited by 91
Otake, Y., Wang, A. S., Webster Stayman, J., Uneri, A., Kleinszig, G., Vogt, S., Khanna, A. J., Gokaslan, Z. L., & Siewerdsen, J. H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8535 · Cited by 89
“Alternatively, Mahfouz et al (2003), Dennis et al (2005), and Turgeon et al (2005) used a modified downhill simplex optimization in which the optimization search is restarted after convergence or a randomly perturbed starting point is used.”
Method3D-2D Registration of Cerebral Angiograms: A Method and Evaluation on Clinical Images
Mitrovic, U., Spiclin, Z., Likar, B., & Pernus, F. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2259844 · Cited by 67
“[26] registered a triangulated mesh model of vasculature, extracted from a pre-EIGI 3D image by multiscale segmentation, to segmented 2D image(s) by using entropy correlation coefficient as similarity measure.”
Metadata
- Authors
- Turgeon, G., Lehmann, G., Guiraudon, G., Drangova, M., Holdsworth, D., & Peters, T.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2005-11-21
- Volume
- 32
- Issue
- 12
- Pages
- 3737-3749
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2066993558
- Cited by
- 82
- References
- 1
- FWCI
- 6.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 2D‐3D registration of coronary angiograms for cardiac procedure planning and guidance. https://app.cochat.ai/papers/10.1118/1.2123350
- The paper
- Turgeon, G., Lehmann, G., Guiraudon, G., Drangova, M., Holdsworth, D., & Peters, T. (2005). 2D‐3D registration of coronary angiograms for cardiac procedure planning and guidance. Medical Physics. https://doi.org/10.1118/1.2123350
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.