The DOI matches its Crossref record.
Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
Abstract
High-density objects such as metal prostheses, surgical clips, or dental fillings generate streak-like artifacts in computed tomography images. We present a novel method for metal artifact reduction by in-painting missing information into the corrupted sinogram. The information is provided by a tissue-class model extracted from the distorted image. To this end the image is first adaptively filtered to reduce the noise content and to smooth out streak artifacts. Consecutively, the image is segmented into different material classes using a clustering algorithm. The corrupted and missing information in the original sinogram is completed using the forward projected information from the tissue-class model. The performance of the correction method is assessed on phantom images. Clinical images featuring a broad spectrum of metal artifacts are studied. Phantom and clinical studies show that metal artifacts, such as streaks, are significantly reduced and shadows in the image are eliminated. Furthermore, the novel approach improves detectability of organ contours. This can be of great relevance, for instance, in radiation therapy planning, where images affected by metal artifacts may lead to suboptimal treatment plans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
CT artifacts: causes and reduction techniques
Boas, F. E., & Fleischmann, D. (2012) · Imaging in Medicine · doi:10.2217/iim.12.13 · Cited by 848
Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography
Zhang, Y., & Yu, H. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823083 · Cited by 493
Metal Artifact Reduction in CT: Where Are We After Four Decades?
Gjesteby, L., De Man, B., Jin, Y., Paganetti, H., Verburg, J., Giantsoudi, D., & Wang, G. (2016) · IEEE Access · doi:10.1109/access.2016.2608621 · Cited by 290
Dual-Energy CT for the Musculoskeletal System
Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2016) · Radiology · doi:10.1148/radiol.2016151109 · Cited by 242
Meyer, J. S., Nadel, H. R., Marina, N., Womer, R. B., Brown, K. L. B., Eary, J. F., Gorlick, R., Grier, H. E., Randall, R. L., Lawlor, E. R., et al. (2008) · Pediatric Blood & Cancer · doi:10.1002/pbc.21596 · Cited by 180
Metadata
- Authors
- Bal, M., & Spies, L.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2006-07-24
- Volume
- 33
- Issue
- 8
- Pages
- 2852-2859
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2023160828
- Cited by
- 234
- References
- 0
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. https://app.cochat.ai/papers/10.1118/1.2218062
- The paper
- Bal, M., & Spies, L. (2006). Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. Medical Physics. https://doi.org/10.1118/1.2218062
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.