The DOI matches its Crossref record.
Properties of preprocessed sinogram data in x-ray computed tomography: Properties of preprocessed sinogram data in x-ray CT
Abstract
The accurate determination of x-ray signal properties is important to several computed tomography (CT) research and development areas, notably for statistical reconstruction algorithms and dose-reduction simulation. The most commonly used model of CT signal formation, assuming monoenergetic x-ray sources with quantum counting detectors obeying simple Poisson statistics, does not reflect the actual physics of CT acquisition. This paper describes a more accurate model, taking into account the energy-integrating detection process, nonuniform flux profiles, and data-conditioning processes. Methods are developed to experimentally measure and theoretically calculate statistical distributions, as well as techniques to analyze CT signal properties. Results indicate the limitations of current models and suggest improvements for the description of CT signal properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
Low-Dose X-ray CT Reconstruction via Dictionary Learning
Xu, Q., Yu, H., Mou, X., Zhang, L., Hsieh, J., & Wang, G. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2195669 · Cited by 690
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Tensor-Based Formulation and Nuclear Norm Regularization for Multienergy Computed Tomography
Semerci, O., Hao, N., Kilmer, M. E., & Miller, E. L. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2014.2305840 · Cited by 389
Metadata
- Authors
- Whiting, B. R., Massoumzadeh, P., Earl, O. A., O'Sullivan, J. A., Snyder, D. L., & Williamson, J. F.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2006-08-24
- Volume
- 33
- Issue
- 9
- Pages
- 3290-3303
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2064526599
- Cited by
- 198
- References
- 0
- FWCI
- 5.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Properties of preprocessed sinogram data in x-ray computed tomography: Properties of preprocessed sinogram data in x-ray CT. https://app.cochat.ai/papers/10.1118/1.2230762
- The paper
- Whiting, B. R., Massoumzadeh, P., Earl, O. A., O'Sullivan, J. A., Snyder, D. L., & Williamson, J. F. (2006). Properties of preprocessed sinogram data in x-ray computed tomography: Properties of preprocessed sinogram data in x-ray CT. Medical Physics. https://doi.org/10.1118/1.2230762
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.